At turn on TPS/T is connected to the inner reference and this state is signalled by the led
corresponding to the button INT at the voice FREQ. REF.
To connect the output frequency to the network frequency, push the button LINE; in this case the
output frequency is brought at 50 Hertz (this is indicated by the flashing of the visualized
frequency); when the connections with the 50 Hertz takes place, TPS/T is connected to the
network frequency and the display concerning the frequency switches off.
The state of connections to the network is indicated by the led corresponding to the button LINE.
TPS/T connects itself to the medium frequency of the network (with a period of integration equal
to about 30 seconds) to eliminate probable line voltage failures or spurious impulses arranged on
the same line.
To return to the inner frequency reference push the button INT, after about 10 seconds the
display will visualize 50.00 and the output frequency will be connected to the inner reference.
3.7.
MODE MENU
3.7.1.
Voltage reaction
The stabilization of the output voltage coincides both on the TPS/T output terminals (2-wires) and
on a possible long distance outlet (4-wires) to eliminate the fall in voltage influence of the
connections.
To operate the long-distance stabilization first connect the SENSE terminals on the back of the
machine following the indications at the voice INSTALLATION.
The choice of the kind of long-distance stabilization can be operated by means of the buttons 4
wires and 2 wires at the voice SENSE.
Notice that TPS/T corrects falls in voltage on the connections until 5% of the set-up voltage to
avoid possible overheating of the line; after exceeding this limit TPS/T
doesn’t gu
arantee that the