27/01/22
User Manual TPS/T 10-90kVA 62000560_09_
12
2.
MODELS
All TPS/T models characteristics are shown in the table hereunder.
TPS/T 7.5K22.5S (10K)
TPS/T 15K45S (20K)
TPS/T 30K60S (40K)
TPS/T 60K
TPS/T 50K120S (60K)
TPS/T 90K
Code
99110547
99110557
99110585
99110540
99116523
99110600
Configuration
Continuous
Inrush
Continuous
Inrush
Continuous
Inrush
Continuous
Continuous
Inrush
Continuous
Power
10KVA
7.5KVA/22.5KVA
20KVA
15KVA/45KVA
40KVA
30KVA/60KVA
72kVA
72KVA
50K120S
95kVA
Output
1phase / 3phase
1phase / 3phase
1phase / 3phase
1phase / 3phase
1phase / 3phase
3phase
Characteristic
Isolated
Isolated
Isolated
Isolated
Isolated
Isolated
Voltage
Range
150V/300V
1)
150V/300V
1)
150V/300V
1)
150V/300V
1)
150V/300V
1)
150V/300V
1)
Accuracy
<0.5% f.s.
<0.5%. f.s.
<0.5% f.s.
<0.5% f.s.
<0.5% f.s.
<0.5% f.s.
Distortion
<0.3%
2)
<0.3%
2)
<0.3%
2)
<0.3%
2)
<0.3%
2)
<0.3%
2)
Stability of the output voltage
<0.1% f.s.
<0.1% f.s.
<0.1% f.s.
<0.1% f.s.
<0.1% f.s.
<0.1% f.s.
Recovery time of the waveform
<10ms
<10ms
<10ms
<10ms
<10ms
<10ms
Maximum Compensated drop
5% s.v.
5% s.v.
5% s.v.
5% s.v.
5% s.v.
5% s.v.
Recovery-time of drop on wires
<200ms.
<200ms.
<200ms.
<200ms.
<200ms.
<200ms.
Output voltage resolution
0.025% f.s.
0.025% f.s.
0.025% f.s.
0.025% f.s.
0.025% f.s.
0.025% f.s.
Maximum current single phase
Configuration
Continuous
Inrush
Continuous
Inrush
Continuous
Inrush
Continuous
Continuous
Inrush
Continuous
Range
150V
300V
150V
300V
150V
300V
150V
300V
150V
300V
150V
300V
150V
300V
150V 300V 150V 300V
150V
300V
RMS continuous
2)
66.7A
33.3A
49.6A
24.8A
133A
66.5A
100A
50A
267A
133A
200A
100A
480A
240A
480A 240A 340A 170A
No single phase option
Inrush Current (3 seconds)
2)
No Inrush
149A
74.4A
No Inrush
300A
150A
No inrush
400A
200A
No inrush capability
No inrush
960A 480A
No single phase option
Maximum current three phase
Configuration
Continuous
Inrush
Continuous
Inrush
Continuous
Inrush
Continuous
Continuous
Inrush
Continuous
Range
150V
300V
150V
300V
150V
300V
150V
300V
150V
300V
150V
300V
150V
300V
150V 300V 150V 300V
150V
300V
RMS continuous
2)
22.2A
11.1A
16.6A
8.33A
44.4A
22.2A
33.3A
16.7A
88.9A
44.5A
66.6A
33.3A
160A
80A
160A
80A
112A
56A
213A
107A
Inrush Current (3 seconds)
2)
No Inrush
50A
25A
No Inrush
100A
50A
No inrush
133A
66.7A
No inrush capability
No inrush
320A 160A
No inrush capability
Frequency
Output frequency range
40Hz
3)
- 80Hz
4)
40Hz
3)
- 80Hz
4)
40Hz
3)
- 80Hz
4)
40Hz
3)
- 80Hz
4)
40Hz
3)
- 80Hz
4)
40Hz
3)
- 80Hz
4)
Range of synchronization
45Hz - 65Hz
45Hz - 65Hz
45Hz - 65Hz
45Hz - 65Hz
45Hz - 65Hz
45Hz - 65Hz
Frequency resolution
0.02Hz
0.02Hz
0.02Hz
0.02Hz
0.02Hz
0.02Hz
Frequency precision
100ppm
100ppm
100ppm
100ppm
100ppm
100ppm
Supply
Input supply
400Vac ± 10% 3Ph
Without neutral
400Vac ± 10% 3Ph
Without neutral
400Vac ± 10% 3Ph
Without neutral
400Vac ± 10% 3Ph
Without neutral
400Vac ± 10% 3Ph
Without neutral
400Vac ± 10% 3Ph
Without neutral
Maximum Input current
20A
70A
120A
160A
250A
250A
Input Frequency
50Hz-60Hz
50Hz-60Hz
50Hz-60Hz
50Hz-60Hz
50Hz-60Hz
50Hz-60Hz
Other
Size (H : W : D)(mm)
1670 : 620 : 625
1670 : 920 : 625
1670 : 920 : 625
1800 :1200 : 800
1800 :1200 : 800
1800 :1200 : 1000
Weight
200Kg
400Kg
600Kg
960Kg
1000Kg
1200Kg
Protections
OVP;UVP;OTP
OVP;UVP;OTP
OVP;UVP;OTP
OVP;UVP;OTP
OVP;UVP;OTP
OVP;UVP;OTP
Operation Temperature Range
0-35°C
0-35°C
0-35°C
0-35°C
0-35°C
0-35°C
RS232
YES
YES
YES
YES
YES
YES
RS485
OTION
OPTION
OPTION
OPTION
OPTION
LAN
OPTION
OPTION
OPTION
OPTION
OPTION
OPTION
1)
Other Range on request
2)
With Resistive load
3)
It is possible on remote interface to set 10Hz but the maximum possible voltage decreases
4)
You can set up 320Hz by serial command, but with derating of performance and maximum voltage
f.s. stands for full scale
s.v. stands for set value