8.2 Device parameters (in alphabetic order)

Parameter

Description

Available options

Default

Deg corr

Angular scale

correction

Programmable value:

0.000001

 

+/-

 

9.999999.

0.00000 cannot be accepted 

(the coefficient is automatically 

set to 1.00000).

1.000000

Deg res

Resolution of the

angular

measurement

The parameter allows to define 

the resolution of angular 

measurement. 

The available options are:

  

1; 0.1; 0.01

0.01

Dir

Measurement 

direction

Set direction of the 

positive axis

dir— ( )

--dir ( )

dir--

 

( )

FLIPp_tG

Arrow to target

indicators direction

 or   

5

The parameter set the direction 

of the arrow indicators when the 

target is not reached.

Lin corr

Linear scale 

correction

Programmable value:

0.000001

 

+/-

 

9.999999.

0.00000 cannot be accepted 

(the coefficient is automatically 

set to 1.00000). 

1.000000

Offset

Offset Value

Programmable value:

Res = 1:
-999999 ÷ 999999
Res = 0.1:
-99999.9 ÷ 99999.9
Res = 0.01:
-9999.99 ÷ 9999.99
Res =0.001:
-999.999 ÷ 999.999

The system allows you to store up 

to 10 compensation values: OFS 

0 ... OFS 9

0000.00

Содержание CE.99951

Страница 1: ...Electronic Magnetic Meter OPERATING INSTRUCTION MPI R10 ...

Страница 2: ...ing mode 11 7 1 Absolute incremental measuring mode selection 11 7 2 Unit of measure selection 11 7 3 Setting the absolute reference 12 7 4 Direct programming of the absolute reference value and compensation 12 7 5 Target positions 13 7 6 Angular measurement 14 8 Programming mode 15 8 1 Programming parameters with numeric values 15 8 2 Device parameters in alphabetic order 16 8 3 Main menu tree 19...

Страница 3: ...t regulations regarding accident prevention and environmental care are to be considered and observed This manual is a supplement to already existing documentation product information mounting instructions catalogues Intended purpose of the equipment Intended purpose of the equipment is industrial process monitoring and control in packaging wood plastic paper glass and textile etc industry It is im...

Страница 4: ...efore any action Maintenance should be performed by trained and authorised persons only 2 System description The MPI R10 made of a LCD multifunction display that connected with a dedicated sensor FC MPI combined with the Elesa magnetic band M BAND 10 is a complete system for the measurement of linear and angular displacement Characterised by extremely easy assembly it allows precise alignment and ...

Страница 5: ... 0 001 in 0 01 Precision 3 0 1mm Repeat accuracy 4 0 1 mm Self diagnostic battery check sensor check magnetic tape check Protection level IP54 or IP67 Operating temperature 0 C 50 C Storage temperature 20 C 60 C Relative humidity max 95 a 25 C without condensation Environment indoor use Altitude up to 2000 m 1 The reading speed influences the battery life 2 Resolution the smallest change in length...

Страница 6: ... and an adhesive tape Fig 2 The cover strip is made of a protection strip and an adhesive tape Fig 1 M BAND 10 Technical data Accuracy class 40 µm Material magnetic tape nitrilic rubber carrier strip stainless steel cover strip stainless steel acrylic adhesive tape Width magnetic band 10 mm 0 20 mm cover strip 10 mm 0 20 mm Thickness magnetic band 1 43 0 15 mm cover strip 0 23 mm Magnetic pole pit...

Страница 7: ...e carefully Remove the protective foil from the adhesive tape of the magnetic band Stick the magnetic band on the mounting surface Clean the surface of the magnetic band carefully Remove the protective foil from the adhesive tape of the cover strip Stick the cover strip on the magnetic band The cover strip must be installed over the magnetic band to protect it from possible mechanical damages In t...

Страница 8: ...To switch the indicator on hold the key mm inch press the key SET The display will light up and the indicator is ready to be used 4 1 Switching off the system only for storage To switch the system off enter the programming mode select rESEt see cap 8 3 press SET press ABS REL press mm inch The display will turn off and the indicator will go into low power mode 5 Display 1 Absolute incremental mode...

Страница 9: ...ssigned to any function in the operating mode Digit increase Scroll for parameters bottom top on the menu tree ABS REL Select the ABS absolute measuring mode REL incremental measuring mode It is possible to choose one of the following options see the _ _ 0 _ _ _ _ voice of the menu cap 8 3 ArCLr DEFAULT switching from ABS to REL the counter is set to zero Ar switching from ABS to REL the counter i...

Страница 10: ...alue to the sum of the parameters OriGin and OFFSET OFF the key combination is not assigned to any function in the operating mode SET ORG Programmable with one of the following options see the _ _ _ _ 0 _ 0 voice of the menu cap 8 3 tArGEtS the keys combination allows to load program one of the 32 target positions See 8 4 OFF DEFAULT the key is not assigned to any function in the operating mode mm...

Страница 11: ...elected the value is always reset to zero Ar passing from ABS to REL the relative measurement is not reset to zero OFF the key is disabled and does not allow changing the selected measuring mode 7 2 Unit of measure selection Press the key mm inch to select the unit of measure The options available are millimeters inches and degrees The measuring mode selected is shown on the display by the symbols...

Страница 12: ...BS REL SET choose the wanted compensation offset pressing the key ABS REL confirm the selection pressing the key SET WARNING To access thi function verify the seting at the menu voice __0___0 see cap 8 3 The available options are LOAdOrG the key combination allow to choose an offset compensation OFF the keys combination is disabled 7 4 Direct programming of the absolute reference value and compens...

Страница 13: ...the keys ABS REL and ORG press the key SET to select the value of the selected target is shown press SET again to confirm or press mm inch to go back to the target selection list If one target is selected one of the symbols will appear on the top right of the display to suggest the direction of movement of the sensor to get to the target position It is possible to set the FLIP_tG parameter see cap...

Страница 14: ...e distance to the set target If the target is not reached the disply blinks Pressing the key ORG the display shows the actual absolute position It is possible to program the keys combination SET ORG to give direct access to the target setup selecting tArGEt in the menu voice _ _ _ _ 0 _ 0 see cap 8 3 If a target is selected is possible to cancel it by pressing the keys combination SET ORG and conf...

Страница 15: ...he programming mode is automatically dropped after 30 seconds of inactivity 8 1 Programming parameters with numeric values Press the key mm inch to select the digit to change Then use ABS REL and ORG to respectively decrease or increase the flashing digit Press the key SET to confirm the value and go back to the list of parameters The numeric values of the parameters must be inserted taking into a...

Страница 16: ... define the resolution of angular measurement The available options are 1 0 1 0 01 0 01 Dir Measurement direction Set direction of the positive axis dir dir dir FLIPp_tG Arrow to target indicators direction or 5 The parameter set the direction of the arrow indicators when the target is not reached Lin corr Linear scale correction Programmable value 0 000001 9 999999 0 00000 cannot be accepted the ...

Страница 17: ...o enter the programming mode OFF DEFAULT the system does not require a password to enter the programming mode OFF P toll Tolerance of target position 0 01 9 99 The parameter value depends on the unit of measure selected 0 10 Radius Radius of the circumference where the reading sensor moves Programmable value 0 01 9999 99 The parameter allows to define the radius of the arc where the magnetic band ...

Страница 18: ...ing max speed Programmable value 1 2 3 4 5 The parameter set the maximum speed of the movement in m s that can be correctly read 3 Targets Target value Programmable value Res 1 999999 999999 Res 0 1 99999 9 99999 9 Res 0 01 9999 99 9999 99 Res 0 001 999 999 999 999 The system allows you to store up to 32 compensation values LtG01 LtG32 The parameter value depends on the unit of measure and resolut...

Страница 19: ...999999 999999 6 OFS 9 SPEEd SPEEd 1 SPEEd 5 rES _ _ O _ _ _ _ a ArClr default OFF Ar P_toll _ _ _ _ O _ _ a _ _ _ _ O _ O a tArGEtS default OFF 0 01 1 99 dd_toGo default d_tArGt OFF If mm 1 0 1 0 01 If inch 1 0 1 0 01 0 001 LinCorr 0 000001 9 999999 dEGCorr 0 000001 9 999999 AnGuLAr Radius dEG_rES 0 01 9999 99 1 0 1 0 01 FLIP_tG FLIP 7 O _ _ _ _ _ O a PrOGOrG default OFF PrOGOFS tArGEtS See cap 8 ...

Страница 20: ...e display shows GO At this point the user must slowly move the sensor in one direction along the magnetic band After the GO it will be displayed a progress bar that will grow as long the sensor is moved The procedure end when the position measurement is shown again by the display This operation allow the sensor to be accurately bound to the magnetic tape and have to be done every time after the in...

Страница 21: ...e measured call it M in a reference point call it K The Correction fator will be equal to K M Verify if the measurements done in the reference and or other known points are correct 8 5 5 Revision As last voice in the main menu starting with the r letter are shown the release data of the device that can be scrolled pressing the key SET Please note these values and communicate them to Elesa in case ...

Страница 22: ...connected Connect the sensor or verify the cable and the connector no tAPE The magnetic tape is not detected Verify if the sensor is correctly mounted near to the magnetic tape SPeed X The sensor is moving too fast according the value of the set in the Speed parameter X is the present setting of the Speed parameter Press SET to go back to the value reading and re set the absolute reference Flashin...

Страница 23: ......

Страница 24: ... COPYRIGHT ELESA 2019 Art Nr ZDOIU MPI R10 ELESA S p A Via Pompei 29 20900 Monza MB Italy phone 39 039 28111 fax 39 039 836351 info elesa com www elesa com ...

Отзывы: