16
EN
MPI-R10
Magnetic measuring system
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
8.2 Device parameters (in alphabetic order)
Parameter
Description
Available options
Default
Deg corr
Angular scale
correction
Programmable value:
0.000001
+/-
9.999999.
0.00000 cannot be accepted
(the coefficient is automatically
set to 1.00000).
1.000000
Deg res
Resolution of the
angular
measurement
The parameter allows to define
the resolution of angular
measurement.
The available options are:
1; 0.1; 0.01
0.01
Dir
Measurement
direction
Set direction of the
positive axis
dir— ( )
--dir ( )
dir--
( )
FLIPp_tG
Arrow to target
indicators direction
or
5
The parameter set the direction
of the arrow indicators when the
target is not reached.
Lin corr
Linear scale
correction
Programmable value:
0.000001
+/-
9.999999.
0.00000 cannot be accepted
(the coefficient is automatically
set to 1.00000).
1.000000
Offset
Offset Value
Programmable value:
Res = 1:
-999999 ÷ 999999
Res = 0.1:
-99999.9 ÷ 99999.9
Res = 0.01:
-9999.99 ÷ 9999.99
Res =0.001:
-999.999 ÷ 999.999
The system allows you to store up
to 10 compensation values: OFS
0 ... OFS 9
0000.00