15
EN
MPI-R10
Magnetic measuring system
Magnetic measuring system
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
8. Programming mode
Press the key
SET
for 3 seconds to enter the programming mode. Depending
on the setting of PASS parameter (see cap. 8.2), the system may require you to
enter a password.
Press the key
ABS-REL
and
ORG
to scroll through the list of parameters and selct the
wanted one pressing
SET
.
Press the key
mm-inch
to exit the programming mode. The programming mode is
automatically dropped after 30 seconds of inactivity.
8.1. Programming parameters with numeric values
Press the key
mm-inch
to select the digit to change. Then use
ABS-REL
and
ORG
to
respectively decrease or increase the flashing digit.
Press the key
SET
to confirm the value and go back to the list of parameters.
The numeric values of the parameters must be inserted
taking into account the selected unit of measure.
When a parameter is changed from its stored value, confirming it, the display will
show the message
CHAnGEd
.
When exiting from the programming mode, the parameter are stored in the
internal memory. If a parameter was changed, the display will show the message
StorEd
.