GB-12
GB
Operating voltage
3 V DC
Battery type
CR 2032
Protection class
IP 20
Permitted ambient temperature
0° to +50 °C
Radio frenquency
868,3 MHz
Deletion of individual transmitters
1. Open the front cover and press
simultaneously
:
• Programming button
P
•
STOP
-button
2. Hold down this button combination until the LED goes out
briefly.
Deletion of all transmitters
1. Open the front cover and press
simultaneously
:
• Programming button
P
•
UP
-button
•
STOP
-button
•
DOWN
-button
2. Hold down this button combination until the LED goes out
briefly 3 times.
Technical data
The maximum sending range within a building is up to 20 m and
in the open air up to 150 m.
GB-11
Deletion of radio/technical data
Battery changing/Cleaning/Troubleshooting
Changing the battery
1. Push the wall transmitter up out
of the wall holder.
2. Remove the battery.
3. Insert a new battery
correctly
.
Cleaning
Clean the device with a damp
cloth only.
Do not use cleaning solutions,
as these may damage the plastic.
Notes on troubleshooting
Fault
Cause
Remedy
CR
2032
The drive does not run,
the transmission indi-
cator lamp
doesn’t light up.
The drive does not run,
the transmission indi-
cator lamp stays on.
The automatic switch
commands are not
carried out.
Drive operates in the
wrong direction.
1. Install a new battery.
2. Install the battery
correctly.
1. Reduce distance to the
receiver.
2. Program the transmitter
Set the UniTec-868 to
"AUTO“.
Delete transmitter and
program correctly.
1. The battery is empty.
2. The battery is incorrectly
installed.
1. The receiver is outside of
sending range.
2. Transmitter not pro-
grammed into receiver.
The UniTec-868 is set to
"Manual “ operation.
Directions are incorrectly
programmed.
General conformity declaration:
The company Firma elero GmbH herewith declares that the
UniTec-868 conforms to the basic requirements and other relevant
regulations of Directive 1999/5/EC.
Содержание UniTec-868