2  

Pull out the plug. 

3  

Insert the motor cable plug until the lock engages. 

Removing and inserting the motor cable plug 

Delivery 

condition 

Removing plug 

Inserting plug 

Fig. 4  Removing and inserting the motor cable plug 

5.3  Connection example for RolMotion/D+ M  

230 V / 50 Hz 

1 0 2

reseau electrique

L

N

PE

230V/50Hz

ver

t-j

aune

br

un

no

ir

ble

u

de volet

M

1~

1 0 2

rete

L

N

PE

230V/50Hz

ver

de

/g

ial

lo

m

ar

rone

ner

o

blu

M

1~

1 0 2

Netz

L

N

PE

230V/50Hz

gr

ün/

gel

b

br

aun

sc

hw

ar

z

bla

u

oder -taster

M

1~

1 0 2

power grid

L

N

PE

230V/50Hz

gr

ee

n/

Yel

low

br

own

bl

ac

k

blu

e

junction box

M

1~

boiter de

scatola di

derivatione

(3)

(2)

(1)

(3)

(2)

(1)

Fig. 5    Connection diagram RolMotion/D+ M 230 V / 50 Hz 

and cable assignment when using Hirschmann plug 

connection STAS-3 

Important 

The motor controls in the Open and Down/Closed travel 

directions must be locked against each other. 
A switching time of at least 0.5 seconds must be observed. 

5.4  Parallel circuit 

Important 

You can connect up to 3 (maximum) RolMotion/D+ M in 

parallel. Please note the maximum switching capacity of 

the control unit. 
However, the behaviour of the devices is not synchronous. 
Do not connect the RolMotion/D+ M drive in parallel with 

other drives (e.g. elero RolTop M). 

5.5  Commissioning 

Important 

The drive is in commissioning mode when delivered. 

 

The end positions may need to be adjusted using the 

elero

 assembly cable (see Fig. 6). 

 

The assembly cable may only be connected to commis-

sion the drive and for adjustment operations 

1

2

3

5.5.1  Connection for assembly cable 

%ODX1HXWUDOOHLWHU

6FKZDU]

%UDXQ

*UQJHOE

HOHUR

HOHUR

%ODX1HXWUDOOHLWHU

6FKZDU]

%UDXQ

*UQJHOE

Fig. 6  Connection for assembly cable 

 

Switch on mains. 

 

You can now set the end positions with the 

elero

 assem-

bly cable. 

5.5.2 

Automatic configuration of end positions 

Important 

To use travel profiles, the upper and lower end positions 

must first be set. During the “Setting the end positions” pro-

cess, the blind moves in the “Standard mode” travel profile. 

Automatic programming of end positions 

1  Connect the electric power in accordance with 

section 5.2. 

2  Check for functioning: If necessary, change or swap 

the assignment of the direction buttons for the operat-

ing switch/push button. 

The drive switches off automatically when the upper or 

lower limit stop is reached. 
The teaching process is completed due to subsequent 

travel of the shutter. 

5.5.3  Changing/deleting the end positions 

It is not possible to change or delete individual end posi-

tions. This is always done in pairs (upper and lower end 

position simultaneously). 

Changing/deleting the end positions 

Switch on mains 

Use the assembly cable to bring the blind to a central 

position. 

Press both direction keys [

UP

 ▲]+[

DOWN/CLOSE 

▼] 

simultaneously. 

The drive travels up and down briefly for approx. 5 seconds. 

The end position settings have been deleted. 

The end positions are configured again automatically as 

described in chapter 5.5.2. 

Travel profiles 

The RolMotion/D+ M drive has two travel profiles, standard 

mode and quiet mode. 

6.1  Standard mode 

When travelling at high speed, only the roller blind slats are 

lowered slowly. 
This travel is triggered by simply turning on the wall switch/

button. 

6.2  Quiet mode 

Travel at slow speed along the entire travel path. 

 © 

elero

 GmbH

  

EN | 5

Assembly | Electrical connection | Adjusting the end positions 

Содержание RolMotion/D+ M Series

Страница 1: ...instructions refers to the laws and regulations that are currently valid in Germany All information in these operating instructions must be complied with at all times and without limitation In additi...

Страница 2: ...ons and valid laws on environmental protection Use according to its intended purpose also includes the compliance with all prescribed operating regu lations in these operating and assembly instruction...

Страница 3: ...rect assembly can lead to serious injuries Commissioning of the RolMotion D M with elero assem bly cable for setting various functions Before installation all cables and components that are not requir...

Страница 4: ...pable of conducting electricity are connected with the protective conductor system of the fixed electrical installation which is located at potential earth The protective conductor connection is desig...

Страница 5: ...Q JHOE ODX 1HXWUDOOHLWHU 6FKZDU UDXQ U Q JHOE Fig 6 Connection for assembly cable Switch on mains You can now set the end positions with the elero assem bly cable 5 5 2 Automatic configuration of end...

Страница 6: ...mantled and separated properly in addition to observing the environmental and health hazards relating to recycling and disposal CAUTION Environmental damage in case of incorrect disposal Electrical sc...

Страница 7: ...ings Travel profiles Size Type RolMotion D M6 RolMotion D M10 RolMotion D M20 RolMotion D M25 Rated torque Nm 6 10 20 25 Rated speed rpm 14 14 14 14 Speed in motion travel profile rpm 5 5 5 5 Rated vo...

Страница 8: ...D E E 45 O 55 C D 33 33 C D 33 E O 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 E E C D 33 33 C D 33 E 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 We...

Отзывы: