Damage to the drive due to the effect of impact forces. 

 

Slide the drive into the shaft. Never knock the drive in or 

use force! 

 

Take care not to drop the drive! 

Damage or destruction to the drive by drilling. 

 

Never drill the drive! 

Important 

Only fasten the RolMotion/D+ M to the designated fasten-

ing elements. 
Fixed installed control devices need to be attached so they 

are visible. 
•  The blind must be attached to the winding shaft. 
• 

The profile tube must have sufficient clearance from the 

motor tube. 

• 

Make sure there is sufficient axial play (1 - 2 mm) 

Installation in profile tubes

 

Ⓐ 

Push drive with relevant adapter and 

crown into the profile tube. 

 

Install the motor cable so it is pro-

tected to prevent damage from the 

driven part. 

Ⓑ 

Secure the counterpart support to 

prevent axial movement, e.g. screw 

or rivet on the idler.  

Secure the drive axially in the 

support! 

 

Attach the blind to the shaft.

 

Only operate the drive horizontally, as intended, with the 

connection cable leading out from the side and out of the 

blind winding area. 

5.2  Electrical connection 

WARNING 

Faulty electrical connections constitute a fatal hazard. 
Risk of electric shock. 

 

Prior to initial commissioning, check the PE wire is cor-

rectly connected. 

ATTENTION 

Damage to the RolMotion/D+ M due to incorrect electrical 

connection. 

 

Prior to initial commissioning, check the PE wire is cor-

rectly connected. 

Ingress of moisture will damage or even destroy the 

RolMotion/D+ M. 

 

For devices with protection class IP 44, the custom-

er-side connection of the cable ends or plugs (cable feed-

through) can also be implemented according to protection 

class IP 44. 

Damage or destruction of the RolMotion/D+ M for variants 

with 230 V ~ due to incorrect activation. 

 

Switches with an OFF presetting (dead-man's switches) 

for drives are to be attached within visible range of the 

RolMotion/D+ M but away from spontaneously moving 

parts and at a height of more than 1.5 m. 

Connect only in de-energised state. To do this, switch 

the drive cable so it is de-energised. 

1  

Press locking mechanism on the motor cable plug to-

wards the cable using a suitable screwdriver. 

4 | EN 

© 

elero

 GmbH 

Assembly | Mechanical fastening 

Possible danger due to parts that are faulty becoming ener-

gised. 

 

The drive falls under protection class I (protective con-

ductor system). All housing parts of the drive capable of 

conducting electricity are connected with the protective 

conductor system of the fixed electrical installation, which 

is located at potential earth. The protective conductor 

connection is designed so that, the first time the plug is 

inserted, it is connected first and, in case of any damage, 

it is disconnected last. The connecting cable is fitted with 

mechanical strain-relief when inserted in the drive. If the 

cable is torn out, the protective conductor will be torn off 

last. If, in case of a fault, a live cable comes into contact 

with the housing, which is connected with the protec-

tive conductor, a short circuit will generally arise so that 

the fuse itself is triggered and de-energizes the electric 

circuit. No electricity will be conducted to human beings 

in case of a fault. 4-core connecting cables (4 x 0.75 mm

2

 

cross-section with black 

CONINVERS

 plug) are used for 

the electrical connection with an earthing contact that is 

conducted to the exterior. 

CAUTION 

Risk of injury due to malfunctions as a result of incorrect 

assembly. 
Drive is overwound and may destroy parts of the application. 

 

For safe operation, the end positions need to be set/taught. 

 

Manufacturer training is available for specialist companies. 

ATTENTION 

Power failures, breaking of machine parts and other mal-

functions. 

 

For safe operation, assembly must be correct and the 

end position adjustments will have to be carried out upon 

commissioning. 

Damage to RolMotion due to ingress of moisture. 

 

On devices with protection class IP 44, the ends of all 

cables or plugs will need to be protected from ingress 

of moisture. This measure needs to be implemented 

after removing the RolMotion/D+ M from the original 

packaging. 

 

The drive must be installed so that it cannot get wet. 

Important 

In its delivery condition (factory setting), the RolMotion/D+ M 

will be in commissioning mode. 

 

The end positions  

 will need to be set (see section 5.6). 

5.1  Mechanical fastening 

Important preliminary consideration: 

The working area around the installed drive is usually 

very small. For this reason, obtain an overview of how the 

electrical connection has been implemented prior to the 

mechanical installation (see section 5.2) and make the 

necessary changes beforehand. 

ATTENTION 

Crushing or tension will damage the electrical cables. 

 

Install all electrical cabling so that it is not subject to any 

crushing or tensile load 

 

Observe the bending radii of cables (at minimum 50 mm). 

 

Route connecting cables in a downward loop to prevent 

water running into the drive. 

Содержание RolMotion/D+ M Series

Страница 1: ...instructions refers to the laws and regulations that are currently valid in Germany All information in these operating instructions must be complied with at all times and without limitation In additi...

Страница 2: ...ons and valid laws on environmental protection Use according to its intended purpose also includes the compliance with all prescribed operating regu lations in these operating and assembly instruction...

Страница 3: ...rect assembly can lead to serious injuries Commissioning of the RolMotion D M with elero assem bly cable for setting various functions Before installation all cables and components that are not requir...

Страница 4: ...pable of conducting electricity are connected with the protective conductor system of the fixed electrical installation which is located at potential earth The protective conductor connection is desig...

Страница 5: ...Q JHOE ODX 1HXWUDOOHLWHU 6FKZDU UDXQ U Q JHOE Fig 6 Connection for assembly cable Switch on mains You can now set the end positions with the elero assem bly cable 5 5 2 Automatic configuration of end...

Страница 6: ...mantled and separated properly in addition to observing the environmental and health hazards relating to recycling and disposal CAUTION Environmental damage in case of incorrect disposal Electrical sc...

Страница 7: ...ings Travel profiles Size Type RolMotion D M6 RolMotion D M10 RolMotion D M20 RolMotion D M25 Rated torque Nm 6 10 20 25 Rated speed rpm 14 14 14 14 Speed in motion travel profile rpm 5 5 5 5 Rated vo...

Страница 8: ...D E E 45 O 55 C D 33 33 C D 33 E O 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 E E C D 33 33 C D 33 E 45 O 45 O C D 33 45 O O 57 5 E C D 33 45 O O 57 5 E 29 O 49 5 O 49 5 We...

Отзывы: