Digital clocks – NDC Series / User Manual v. 2.11
9
6
In the case of required galvanic separation of devices, it is necessary to use the respective modules in the
modification with galvanic separation
and to provide the powering of the modules from separate power
supplies. In such a case galvanic separation of individual devices in the NDC-net between each-other and
from the mains is guaranteed. This solution is necessary when the device network is larger, and is installed
along power cables, metal piping or near other sources of interference, in an outdoor environment, between
buildings, etc. The power supply is connected to the module through a data distribution box, while its distance
from the module should not exceed 20 m.
5
SETTING, CONTROLLING AND PROGRAMMING OF THE NDC CLOCKS
5.1 Table of the menu, default settings
MENU
Submenu
Display
(alteration
parameter/value)
Default
setting
(after reset)
diSP
DISPLAY
Time reading period
Date reading period
Coundown reading period
Sensor 1 reading period
Sensor 2 reading period
Stopwatch reading period
tMPE
dtPE
CdPE
S1PE
S2PE
StPE
15 s
5 s
0 s
0 s
0 s
0 s
tIME
TIME
Year setting
Month setting
Day setting
Hour setting
Minute setting
Shift of hours setting
Shift of minutes setting
Automatic switching of Daylight saving time on/off
yEAr
Mon
dAy
Hour
Min
Sh_H
Sh_M
dSt
current
current
current
current
current
0
0
On
Cnt
COUNTER
Count direction setting
Limit – days setting
Limit – hours setting
Limit – minutes setting
Limit – seconds setting
Relay period setting
Counter repeat setting
Counter correction enable/disable
Cdir
LM_d
LM_H
LM_M
LM_S
rLPE
CrPt
Ccor
uP
0
0
0
0
0
OFF
On
Set
SET
Brightness setting
Display address setting
Configuration, see submenu
Sensor 1 address setting
Sensor 2 address setting
Push-button address setting
Remote output address setting
Synchronization period setting
Stopwatch mode setting – for NDC xxx/4
– for NDC xxx/6
BriG
diAd
ConF
S1Ad
S2Ad
PbAd
roAd
SyPE
StMo
15 (max)
001
(Master)
–
000
000
000
000
1
M99
M59
PrG
PROGRAM
Switch on time
Relay period
Week days
S_tM
rEL
WdA
all 00:00
all 0
all OFF
ConF submenu, network configuration
(Configuration)
ConF
Configuration run
run
Device list
LiSt
Reset to default settings
rSt
7
5.2 Layout of IR controller’s buttons
5.3 Work with the menu, control through the IR controller
In the display mode, the clock does not accept any control codes from the IR controller except the code of the
SELECT
button. That prevents inadvertent simultaneous setting of several clocks, if they are too close to each
other (within the range of the IR). When you push the
SELECT
button, the display will show its address in the
{Axxx} format, where xxx is a number from the range 0 to 126. The required clock is selected by entering its
three-digit address
0 – 9
buttons without the need to confirm. When a correct address is entered, {Menu} will
be displayed on the respective clock, which means that the clock is in the setting mode. If an incorrect address
is set or the address is not entered within 3 seconds, the display will move automatically into the standard
displaying mode. {Menu} will be displayed only upon entering the menu to confirm the correctness of the
previous steps, but is it not displayed when browsing in the menu.
Arrow buttons ▲ and ▼ are used for browsing in the menu. A selected submenu should be confirmed by the
OK
button. When the browsing stops in a submenu, after 2 seconds the value of the displayed parameter and
its name will be displayed alternately (value for 0.5 sec / name for 1.5 sec). It is possible to continue with
browsing also in this mode, until the required parameter is found.
To change the value of a parameter confirm that parameter with the
OK
button – its value will be displayed
permanently and it is possible to modify it with numerical buttons. A digit that is being modified will blink. If the
value of the parameter is a non-
numerical one (ON/OFF, decimal point, minus sign), use the ◄/► bu
ttons to
switch to the required value. Confirm the new value by pressing the
OK
button. If the new value is not confirmed
within 7 seconds, a move one level up will occur (i.e. to the list of parameters) and the original value will remain
unchanged.
Button
Colour
Description of function
ESC
ESC to one level up
SELECT
Select device
0 – 9
Enter digits
◄/►
Switch between values, DP
position, +/-
▲
Move up in the menu
▼
Move down in the menu
OK
Confirmation button
►
Start
▐ ▌
Pause
■
Stop
RESET
Reset
▲
up button
►