10

Digital clocks – NDC Series  /  User Manual v. 2.11

8

If the value being confirmed is outside the allowed range, an error message {Err} will be displayed for 3 sec 

after the confirmation. In this case no modification of the value being set will occur (the original one will be 

retained).
In any setting phase it is possible to cancel the setting by pressing the 

ESC

button without modifying the 

parameter being set. This button is used for the return one level up in the menu, up to the complete ending of 

the menu. If no activity is registered in the setting mode (i.e. the menu) for 60 sec, the display will return 

automatically into the display mode.

5.4 Data display period setting {diSP}

({MEnu}→){diSP}→{tMPE}

({MEnu}→){diSP}→{dtPE}

({MEnu}→){diSP}→{CdPE}

({MEnu}→){diSP}→{S1PE}

({MEnu}→){diSP}→{S2PE}

({MEnu}→){diSP}→{StPE}

In this menu you can define the periods for which individual data of the clock will be displayed alternately. The 

respective data is displayed for the set period (e.g. time, {tMPE}) and in the order in which the items are 

arranged in the menu. If any parameter is set to 0, the respective item will not be displayed.
To start the setting, in the main menu activate the {diSP} item and confirm it with the 

OK 

button (see Chapter

5. SETTING, CONTROLLING AND PROGRAMMING OF THE NDC CLOCKS

).

The periods of displaying individual data items is specified in seconds, while it is possible to set that parameter 

for the following items:
{tMPE}

Time Period

default 15;

{dtPE}

Date Period

default 5;

{CdPE} Coundown Period

default 0;

{S1PE} Sensor 1 Period 

default 0;

{S2PE} Sensor 1 Period 

default 0;

{StPE}

Stopwatch period 

default 0.

The range of allowed values of these items is between 0 and 60. If no local or remote (thermal) sensor is 

connected, it is necessary to leave both {S1PE} and {S2PE} = 0.

5.5 Time setting {tIME}

To set the clock, first it is necessary to activate the {tIME} item in the main menu and confirm it with the 

OK

button.

5.5.1 Time setting {Hour}, {Min}

({MEnu}→){tIME}→{Hour}

({MEnu}→){tIME}→{Min}

The time setting consists of the setting of two values:
{Hour}

setting of hours in the range 0 – 23;

{Min}

setting minutes in the range 0 – 59.

In the case of correct setting and confirming of minutes,

the seconds will be reset

at the moment of 

confirmation.
Note:

1. Before the time setting itself, it is necessary to check and set correctly the time zone (shift against the

UTC) for which the set time is to be valid (items {Sh_H} and {Sh_M}). This is important for the correct move

to the winter/summer time; otherwise the move will occur on an incorrect hour (if automatic switching to

the winter/summer time (DST) is enabled, see chapter 5.5.4 Switching between the summer/winter time

(Daylight Saving Time) {dSt}). For the Central European Time (CET) the shift is +1 hour, for the UTC/GMT

time the shift is 0. When the time zone is set, the clock will display the local time.

2. If the local time is set first and the time zone second, the clock will display the shifted time.

5.5.2 Date setting {YEAr}, {Mon}, {dAY} 

({MEnu}→){tIME}→{YEAr}

({MEnu}→){tIME}→{

Mon}

({MEnu}→){tIME}→{dAY}

Содержание NDC 100/4 R L20

Страница 1: ...Digital clocks NDC 57 4 6 R L20 NDC 100 4 6 R L20 User Manual v 2 11...

Страница 2: ...dress setting diAd 9 5 6 3 Network configuration ConF 10 5 6 4 Allocation of sensors temperature display address setting S1Ad S2Ad 10 5 6 5 Allocation of the remote button address setting PbAd 10 5 6...

Страница 3: ...4 superbright 7 segment LED modules 4 88 88 57 23 NDC 57 6 6 88 88 88 57 23 NDC 100 4 4 88 88 100 40 NDC 100 6 6 88 88 88 100 40 NDC 160 4 superbright elliptic LEDs for outdoor use 4 88 88 160 70 NDC...

Страница 4: ...DC net Counter counting up down Automatic switching of the display format range 1 s to 99 days 23 hours 59 minutes 59 seconds COUNT UP or COUNT DOWN mode adjustable limit Functions START STOP PAUSE RE...

Страница 5: ...ndicular distance 15 m Time and date setting Activation of selected display modes time date temperature stop watch counter remote sensor intervals of alternating data display Limit and modes for the c...

Страница 6: ...and a protocol converter to the NDC net Sensors Within the range of the NDC net they measure general quantities usually temperature but also humidity pressure and after their processing they send the...

Страница 7: ...network The connectors are located at the back of the display and they are marked as RS485 and 17 V RS485 The type of the connector used and its connection are described in detail in the clock s circ...

Страница 8: ...iod Sensor 2 reading period Stopwatch reading period tMPE dtPE CdPE S1PE S2PE StPE 15 s 5 s 0 s 0 s 0 s 0 s tIME TIME Year setting Month setting Day setting Hour setting Minute setting Shift of hours...

Страница 9: ...layed when browsing in the menu Arrow buttons and are used for browsing in the menu A selected submenu should be confirmed by the OK button When the browsing stops in a submenu after 2 seconds the val...

Страница 10: ...lowing items tMPE Time Period default 15 dtPE Date Period default 5 CdPE Coundown Period default 0 S1PE Sensor 1 Period default 0 S2PE Sensor 1 Period default 0 StPE Stopwatch period default 0 The ran...

Страница 11: ...ed Note If the clock clock network is connected to a synchronisation device GPS receiver etc which itself provides the correction of the summer winter time this function has to be switched off on all...

Страница 12: ...or there may be problems with the communication with that module If there is a synchronisation module with an integrated thermal sensor in the NDC net and there is a requirement to display its tempera...

Страница 13: ...er 5 4 Data display period setting diSP If you want to ensure only the displaying of the stopwatch set the parameters for the rest of the displayed data to 0 Types NDC xxx 4 display the time measureme...

Страница 14: ...he time from the set value downwards to 00 00 00 When the end of the interval is reached the built in relay is switched on while the duration of the switch on state can be adjusted In the settings it...

Страница 15: ...set relay on period is 0 sec the relay will not be switched on at the selected time 2 Switching of the relay is signalized by the LED in the right lower corner after second or minute reading that is t...

Страница 16: ...00 00 for counting up or the preset limit for counting down A short depressing of the button will start the time counting START a short repeated depressing will freeze the current value of the counted...

Страница 17: ...ction at the set time during a day will be active And vice versa if a respective day has the OFF flag e g weekends the relay will not be switched on that day After selecting the Wda item select the re...

Страница 18: ...ices Otherwise the ID table of devices may not correspond with the reality and the configuration may have to be repeated 6 3 Viewing of the list of devices LiSt MEnu SEt ConF LiSt The list of found de...

Страница 19: ...r supply is resumed the relay output will be switched on immediately 8 RESET RESTORING OF ORIGINAL VALUES rSt MEnu SEt ConF rSt A reset will restore the original settings of the clock see chapter 5 1...

Страница 20: ...18 10 CONNECTION DIAGRAM...

Отзывы: