5.8.6.1 Controlling the counter by a remote controller

The counter is started by pressing the 

START 

► button. If, during the counter’s running, no control button is 

depressed, the counter will count up to the value of the set limit (in the UP mode) or down to (00:)00:00 (in the 

DOWN mode). If automatic starting restarting of the counter is enabled ({CrPt} item), when the counter reaches 

the limit, it will be started again from the beginning.
If you depress the 

PAUSE 

▐ ▌

button when the counter is running, the display will “freeze” the current value of 

the counted time (intermediate time), while the counting up/down of the time runs in the background. After 

pressing the 

START 

►again, the display will display the time counted up/down.

If you press the 

STOP

■ 

button during the counter’s running, the display will show the current value of the 

counted time and stop the counding up/down. The pressing of the 

STOP

■ button during the dispaying of the 

intermediate time (i.e. after previous depressing of the 

PAUSE 

▐ ▌

) the counting up/down of the time that was 

running in the background will stop and the resulting time will be displayed.
If the counter is in the “stop” condition, it is possible to start it again with the 

START 

►button from the time it 

displays.
The counter’s reset is done by pressing the 

RESET 

button, the counting up/down of hte time, however, must 

be stopped (stop condition after pressing the 

STOP

■ button).

5.8.6.2 Controlling the counter by a local button (TRIGGER INPUT)

The local button must be connected to the TRIGGER INPUT, see the connection diagram. This method of 

controlling supports only the START and PAUSE functions, which are implemented by a short pressing of the 

button (< 2.5 sekunds). For the RESET function it is necessary to keep the button depressed for more than 

2.5 seconds.
Let us assume the initial state of the counter after power on or after a reset, showing (00:)00:00 (for counting 

up) or the preset limit (for counting down). A short depressing of the button will start the time counting (START), 

a short repeated depressing will “freeze” the current value of the counted up/down time on the display 

(intermediate time), while the counting up/down of the time runs in the background (PAUSE). By further 

pressing of the button, the display will show again the counted up/down time (START), and so on.
The counter’s reset is done by a long depressing of the button in the PAUSE state.

5.8.6.3  

Controlling of the counter by a remote button

The remote button must be connected into the NDC-net and its adddress must be allocated to the clock/counter 

that is to be controlled by it, see chapter 

5.6.5 Allocation of the remote button, address setting {PbAd}

The counter is controlled in the same way as in the case of a local button.

5.9 Switch clock, time interval programming {PrG}

The clock allows to set up to 16 times of switching on the output relay in a single day, the period of the switch-

on state of the relay and a weekly calendar when the switching is active. In order to switch on the relay, the 

following conditions have to be met:

1. The switch on time has arrived and;

2. The relay switch on period > 0 s and;

3. The day given in the weekly calendar is set as active.

If at least one of the above conditions is not met, the relay will not switch on!

The programming of the time intervals is first necessary to activate in the main menu by the {PrG} item and 

then confirm it with the 

OK

button.

5.9.1 Setting the switch on times {S_tM}

({MEnu}→){PrG}→{S_tM}→{tM0}→...→{tM15}

In this part of the menu you can set up to 16 times, {tM0} through {tM15}, at which the output relay of the clock 

will be activated for the required period. When choosing the {S_tM} item, set the time of swithing on that is to 

be set with the arrow buttons ▲ / ▼. After confirming with the 

OK

button you can enter the required value.

{tM0}

Relay switch on time 00:00 through 23:59 (HH:MM)

default 00:00;

...

...

...

{tM15}

Relay switch on period  00:00 through 23:59 (HH:MM)

default 00:00.

The switch on time is set in minutes. It is suitable to occupy the sequence starting from {tM0}. 

Содержание NDC 100/4 R L20

Страница 1: ...Digital clocks NDC 57 4 6 R L20 NDC 100 4 6 R L20 User Manual v 2 11...

Страница 2: ...dress setting diAd 9 5 6 3 Network configuration ConF 10 5 6 4 Allocation of sensors temperature display address setting S1Ad S2Ad 10 5 6 5 Allocation of the remote button address setting PbAd 10 5 6...

Страница 3: ...4 superbright 7 segment LED modules 4 88 88 57 23 NDC 57 6 6 88 88 88 57 23 NDC 100 4 4 88 88 100 40 NDC 100 6 6 88 88 88 100 40 NDC 160 4 superbright elliptic LEDs for outdoor use 4 88 88 160 70 NDC...

Страница 4: ...DC net Counter counting up down Automatic switching of the display format range 1 s to 99 days 23 hours 59 minutes 59 seconds COUNT UP or COUNT DOWN mode adjustable limit Functions START STOP PAUSE RE...

Страница 5: ...ndicular distance 15 m Time and date setting Activation of selected display modes time date temperature stop watch counter remote sensor intervals of alternating data display Limit and modes for the c...

Страница 6: ...and a protocol converter to the NDC net Sensors Within the range of the NDC net they measure general quantities usually temperature but also humidity pressure and after their processing they send the...

Страница 7: ...network The connectors are located at the back of the display and they are marked as RS485 and 17 V RS485 The type of the connector used and its connection are described in detail in the clock s circ...

Страница 8: ...iod Sensor 2 reading period Stopwatch reading period tMPE dtPE CdPE S1PE S2PE StPE 15 s 5 s 0 s 0 s 0 s 0 s tIME TIME Year setting Month setting Day setting Hour setting Minute setting Shift of hours...

Страница 9: ...layed when browsing in the menu Arrow buttons and are used for browsing in the menu A selected submenu should be confirmed by the OK button When the browsing stops in a submenu after 2 seconds the val...

Страница 10: ...lowing items tMPE Time Period default 15 dtPE Date Period default 5 CdPE Coundown Period default 0 S1PE Sensor 1 Period default 0 S2PE Sensor 1 Period default 0 StPE Stopwatch period default 0 The ran...

Страница 11: ...ed Note If the clock clock network is connected to a synchronisation device GPS receiver etc which itself provides the correction of the summer winter time this function has to be switched off on all...

Страница 12: ...or there may be problems with the communication with that module If there is a synchronisation module with an integrated thermal sensor in the NDC net and there is a requirement to display its tempera...

Страница 13: ...er 5 4 Data display period setting diSP If you want to ensure only the displaying of the stopwatch set the parameters for the rest of the displayed data to 0 Types NDC xxx 4 display the time measureme...

Страница 14: ...he time from the set value downwards to 00 00 00 When the end of the interval is reached the built in relay is switched on while the duration of the switch on state can be adjusted In the settings it...

Страница 15: ...set relay on period is 0 sec the relay will not be switched on at the selected time 2 Switching of the relay is signalized by the LED in the right lower corner after second or minute reading that is t...

Страница 16: ...00 00 for counting up or the preset limit for counting down A short depressing of the button will start the time counting START a short repeated depressing will freeze the current value of the counted...

Страница 17: ...ction at the set time during a day will be active And vice versa if a respective day has the OFF flag e g weekends the relay will not be switched on that day After selecting the Wda item select the re...

Страница 18: ...ices Otherwise the ID table of devices may not correspond with the reality and the configuration may have to be repeated 6 3 Viewing of the list of devices LiSt MEnu SEt ConF LiSt The list of found de...

Страница 19: ...r supply is resumed the relay output will be switched on immediately 8 RESET RESTORING OF ORIGINAL VALUES rSt MEnu SEt ConF rSt A reset will restore the original settings of the clock see chapter 5 1...

Страница 20: ...18 10 CONNECTION DIAGRAM...

Отзывы: