background image

4

Digital clocks – NDC Series  /  User Manual v. 2.11

2

The easiest way of controlling the NDC clock is shown in fig. 2.

Fig. 2 The easiest way of controlling the NDC clock.

2

PROPERTIES

2.1 Display functions

Time 

(display format)

HH:MM

(Hours:Minutes)

NDC xxx/4;

HH:MM:SS (Hours:Minutes:Seconds)

NDC xxx/6.

Date 

(display format)

DD:MM

(Day:Month)

NDC xxx/4;

DD:MM:YY (Day:Month:Year)

NDC xxx/6.

Temperature*  

(display format)

-99° ÷ -10° ÷ -9.9° ÷ 99.9°

NDC xxx/4;

-99°C ÷ -10°C ÷ -9.9°C ÷ 99.9°C

NDC xxx/6;

A local thermal sensor (i.e. connected directy to the clock) can be located near the NDC or as part of 

the frame (for extra fee). The precision of the displayed temperature is given by the precision of the 

sensor.

* if a local thermal sensor is connected

Stop watch

SS.ss –> MM:SS

NDC xxx/4

Seconds.hundredths of seconds with automatic switching to Minutes:Seconds when the seconds are 

full;

MM:SS.hh -> HH:MM:SS

NDC .../6m

Minutes:Seconds.hundredths of seconds with selectable automatic switching to Hours:Minutes:Seconds 

or a 99-minute mode (MM:SS.hh)

Functions: START, STOP/FREEZE (intermediate time, the measured time runs in the background), 

RESUME, RESET ;

Automatic restart of the stop watch when the maximum displayable time is reached;

Remote control of the stop watch, external contact (with or without galvanic separation) or with a remote 

button in the NDC-net.

Counter

(counting up/down)

Automatic switching of the display format, range: 1 s to 99 days, 23 hours, 59 minutes, 59 seconds;  

COUNT-UP or COUNT-DOWN mode – adjustable limit;

Functions: START, STOP/PAUSE, RESUME, RESET;

Single or repeated run of the counter when the setup limit is reached;

Switchable counter time correction due to a time change (new time setting) or external time 

synchronisation;

Control of the counter via a remote control, an external contact (with or without galvanic separation) or 

a remote button in the NDC-net;

Possibility to switch on either the internal or a remote relay (close contact) when the limit is reached.

Switch clock

(time interval programming)

Programmable 16 intervals of switching on the output relay in a single day;

Setting of the relay switch on period from 0.01 – 99 sec;

Weekly calendar, setting of switch-on days (from Sunday to Saturday).

Data from remote sensors 

(in NDC-net)

Possibility to display data from 2 remote sensors connected to the NDC-net (e.g. external temperature 

sensor, humidity sensor, pressure sensor, ...). It is possible to set on the clock the remote sensors whose 

data will be displayed. If a local thermal sensor is connected, then it is possible to display just one figure 

from a remote sensor.

The clock allows 

alternate display

of the above data, while the user has the possibility to program the 

duration of their displaying in the range 0 ÷ 60s (0 

no data displayed).

Automatic

(depending on ambient light conditions) or 

manual brightness setting

in 15 levels.

Содержание NDC 100/4 R L20

Страница 1: ...Digital clocks NDC 57 4 6 R L20 NDC 100 4 6 R L20 User Manual v 2 11...

Страница 2: ...dress setting diAd 9 5 6 3 Network configuration ConF 10 5 6 4 Allocation of sensors temperature display address setting S1Ad S2Ad 10 5 6 5 Allocation of the remote button address setting PbAd 10 5 6...

Страница 3: ...4 superbright 7 segment LED modules 4 88 88 57 23 NDC 57 6 6 88 88 88 57 23 NDC 100 4 4 88 88 100 40 NDC 100 6 6 88 88 88 100 40 NDC 160 4 superbright elliptic LEDs for outdoor use 4 88 88 160 70 NDC...

Страница 4: ...DC net Counter counting up down Automatic switching of the display format range 1 s to 99 days 23 hours 59 minutes 59 seconds COUNT UP or COUNT DOWN mode adjustable limit Functions START STOP PAUSE RE...

Страница 5: ...ndicular distance 15 m Time and date setting Activation of selected display modes time date temperature stop watch counter remote sensor intervals of alternating data display Limit and modes for the c...

Страница 6: ...and a protocol converter to the NDC net Sensors Within the range of the NDC net they measure general quantities usually temperature but also humidity pressure and after their processing they send the...

Страница 7: ...network The connectors are located at the back of the display and they are marked as RS485 and 17 V RS485 The type of the connector used and its connection are described in detail in the clock s circ...

Страница 8: ...iod Sensor 2 reading period Stopwatch reading period tMPE dtPE CdPE S1PE S2PE StPE 15 s 5 s 0 s 0 s 0 s 0 s tIME TIME Year setting Month setting Day setting Hour setting Minute setting Shift of hours...

Страница 9: ...layed when browsing in the menu Arrow buttons and are used for browsing in the menu A selected submenu should be confirmed by the OK button When the browsing stops in a submenu after 2 seconds the val...

Страница 10: ...lowing items tMPE Time Period default 15 dtPE Date Period default 5 CdPE Coundown Period default 0 S1PE Sensor 1 Period default 0 S2PE Sensor 1 Period default 0 StPE Stopwatch period default 0 The ran...

Страница 11: ...ed Note If the clock clock network is connected to a synchronisation device GPS receiver etc which itself provides the correction of the summer winter time this function has to be switched off on all...

Страница 12: ...or there may be problems with the communication with that module If there is a synchronisation module with an integrated thermal sensor in the NDC net and there is a requirement to display its tempera...

Страница 13: ...er 5 4 Data display period setting diSP If you want to ensure only the displaying of the stopwatch set the parameters for the rest of the displayed data to 0 Types NDC xxx 4 display the time measureme...

Страница 14: ...he time from the set value downwards to 00 00 00 When the end of the interval is reached the built in relay is switched on while the duration of the switch on state can be adjusted In the settings it...

Страница 15: ...set relay on period is 0 sec the relay will not be switched on at the selected time 2 Switching of the relay is signalized by the LED in the right lower corner after second or minute reading that is t...

Страница 16: ...00 00 for counting up or the preset limit for counting down A short depressing of the button will start the time counting START a short repeated depressing will freeze the current value of the counted...

Страница 17: ...ction at the set time during a day will be active And vice versa if a respective day has the OFF flag e g weekends the relay will not be switched on that day After selecting the Wda item select the re...

Страница 18: ...ices Otherwise the ID table of devices may not correspond with the reality and the configuration may have to be repeated 6 3 Viewing of the list of devices LiSt MEnu SEt ConF LiSt The list of found de...

Страница 19: ...r supply is resumed the relay output will be switched on immediately 8 RESET RESTORING OF ORIGINAL VALUES rSt MEnu SEt ConF rSt A reset will restore the original settings of the clock see chapter 5 1...

Страница 20: ...18 10 CONNECTION DIAGRAM...

Отзывы: