Installation Instructions

5

Step 5

Perform the following tests: Insulation resistance test, a heating cable resistance 
test and a floor sensor resistance test. (see page 7) record your findings in the test & 
commission form enclosed in the box.

Step 8

With the eRibbon laid and secure the finished floor surface can now be laid. When 
using the Duralay Heatflow underlay install directly above the eRibbon

Step 7

Position  the  floor  sensor  thermostat  probe  directly  below  the  electrical  connection 
point.
The floor sensing probe should be installed in-between two heating ribbons and 
secured with the single sided adhesive tape (the floor sensor is used to measure the 
maximum temperature beneath the floor).

Step 6

Unfold the eRibbon with the fibreglass net facing up, lay the eRibbons onto the 
eFoam insulation. Using the doublesided adhesive tape clearly fixed to the eFoam 
ensures the eRibbon is installed with no raised folds. Each pair of cold tails should be 
connected to a low level connection point.

Note

After the finished floor covering has been laid perform the following tests:
•  Insulation resistance test
•  Heating cable resistance test
•  Floor sensor resistance test
Record your findings in the test & commission form enclosed in the box. 

Register your warranty online at: www.electricunderfloorheating.co.uk/warranty

Note 

Do not over lap the eRibbon mats

Содержание eRibbon

Страница 1: ...eRibbon Installation Manual www electricunderfloorheating co uk Before you begin installing read through these instructions carefully and check that you have all the components required...

Страница 2: ...f any heat conductive building part such as cold water pipes Install mats within 5cm of one another 10cm of any wall or 15cm of a fireplace or hot water pipe Connect any other electrical appliance on...

Страница 3: ...cal consumer unit Confirm your thermostat is suitable to switch the appropriate electrical load e g 15A thermostat 230V is suitable to switch up to 22m of eRibbon If you are required to switch greater...

Страница 4: ...ady for the eFoam insulation All loose particles should be removed and the floor thoroughly cleaned and treated with any proprietary sealants as normally required Step 3 Positionandcuttheefoamtofityou...

Страница 5: ...secured with the single sided adhesive tape the floor sensor is used to measure the maximum temperature beneath the floor Step 6 Unfold the eRibbon with the fibreglass net facing up lay the eRibbons...

Страница 6: ...mats as much as possible and the smaller mats only as gap fillers Please find below a list of the available mat sizes complete with the resistances for your reference whilst installing the eRibbon Pr...

Страница 7: ...uctor off the cold tails and earth The meter should record a high resistance value e g above 100 Meg ohms Floor Construction Examples The eRibbon allows direct installation of timber laminate parquet...

Страница 8: ...lpdesk 08714 74 08 18 Contact the eLine Helpdesk with any questions on 08714 74 08 18 eRibbon Edison House Unit 7 Edison Close Ransomes Europark Ipswich Suffolk IP3 9GU United Kingdom Copyright Elemen...

Отзывы: