background image

2

The eLine Brand 

Congratulations on choosing your eRibbon underfloor heating product from the eLine 
range of under floor heating solutions.
The eLine range has been manufactured to exceed all relevant standards and expectations 
considering ease of installation and usability through the lifetime of the product.

The eRibbon Product

The eRibbon mats are constructed from flat amorphous metal ribbons covered by two 
layers of polyethylene electric insulation. The ribbons are evenly spaced on a mesh 
mat providing a simple and easy to install product.

Introduction

Important notes, please read carefully before proceeding with installation 

Do’s & Dont’s

Do

Carefully read this instruction manual before starting your installation and follow 
the testing procedure as detailed on page 7. Throughout your installation:

•  Ensure that the electric circuit that supplies electricity to the eRibbon heating 

system is equipped with a 30Ma residual current device (RCD)

•  Connect all cold tail leads from the eRibbon heating mats in parallel at the 

low level junction box

•  Ensure that the total current for all mats does not exceed more than 80% of 

the current rating of the MCB/ Fuse

•  Use insulation under the mats to reduce costs and warm up time. Check with 

your installer to determine the R value of the sub-floor insulation layer 

Don’t

•  Install mats under walls or partitions, or in areas under heavy cabinets, 

closets, or fixtures (toilets, sinks, tubs, etc.).

•  Install mats within 3cm of any heat conductive building part, such as cold 

water pipes.

•  Install mats within 5cm of one another, 10cm of any wall, or 15cm of a 

fireplace or hot water pipe.

•  Connect any other electrical appliance on the same electric fused spur or RCD 

unit of the heating system.

•  Install heating mats under wooden floor if the wooden floor is thicker than 

18mm.

•  Use carpet underlay with thermal resistance greater than 0.8 Tog.
•  Install under carpet with thermal resistance greater than 2.0 Tog.
•  Overlap heating mats.
•  Fold or wrinkle eRibbon heating mats.
•  Place heavy/sharp tools (or any other potentially damaging object) on top of 

the heating mats.

•  Walk unnecessarily on the heating mats.
•  Use cellulose insulation.
•  Install mats when the room temperature is below -5°C (23°F).
•  Install underfloor heating mats anywhere except inside buildings.

Tools needed for installation

You will require the following items to install and test the floor warming systems.
•  Tape measure, drawing pad and pencil
•  Utility knife, scissors
•  Cable strippers, screw driver
•  Resistance tester (multimeter), insulation resistance tester
You will also need the appropriate tools and materials to install your finished floor surface; 
these will probably include products like double-sided tape, eFoam and various other 
tools and materials for your specific project.

Contents of eRibbon system

•  Heating mat
•  Installation instructions
•  Warranty 
The following pages contain all the information you will need about the eRibbon. 
Please take the time to study this information thoroughly before you attempt to 
install this product.

Glossary of Terms

A

  –  Heating element

B

  –  Fibreglass backing mesh

C

  –  Factory made cold tail joint

D

  –  Cold tail power lead

Содержание eRibbon

Страница 1: ...eRibbon Installation Manual www electricunderfloorheating co uk Before you begin installing read through these instructions carefully and check that you have all the components required...

Страница 2: ...f any heat conductive building part such as cold water pipes Install mats within 5cm of one another 10cm of any wall or 15cm of a fireplace or hot water pipe Connect any other electrical appliance on...

Страница 3: ...cal consumer unit Confirm your thermostat is suitable to switch the appropriate electrical load e g 15A thermostat 230V is suitable to switch up to 22m of eRibbon If you are required to switch greater...

Страница 4: ...ady for the eFoam insulation All loose particles should be removed and the floor thoroughly cleaned and treated with any proprietary sealants as normally required Step 3 Positionandcuttheefoamtofityou...

Страница 5: ...secured with the single sided adhesive tape the floor sensor is used to measure the maximum temperature beneath the floor Step 6 Unfold the eRibbon with the fibreglass net facing up lay the eRibbons...

Страница 6: ...mats as much as possible and the smaller mats only as gap fillers Please find below a list of the available mat sizes complete with the resistances for your reference whilst installing the eRibbon Pr...

Страница 7: ...uctor off the cold tails and earth The meter should record a high resistance value e g above 100 Meg ohms Floor Construction Examples The eRibbon allows direct installation of timber laminate parquet...

Страница 8: ...lpdesk 08714 74 08 18 Contact the eLine Helpdesk with any questions on 08714 74 08 18 eRibbon Edison House Unit 7 Edison Close Ransomes Europark Ipswich Suffolk IP3 9GU United Kingdom Copyright Elemen...