background image

TROUBLESHOOTING

18 / 20

Problem: Irregular flame pattern,flame does not run the full length of the burner

Possible Cause: 

Burner ports are clogged or blocked.

-Clean burner ports. Do this by inserting a paperclip into each of the burner ports to ensure they are 

not clogged.

WARNING: Make sure burner is not on and the gas supply has been properly disconnected. Allow 

15 minutes for unit to cool before touching it.

Problem: Flame blow out

Possible Cause 1: High or gusting winds.

-Increase flame to “HIGH” setting.

Possible Cause 2: Low on Natural gas.

-Call your local gas company.

Possible Cause 3: Excess fl ow valve tripped.

-Refer to “Problem: Sudden drop in gas flow”.

5mm / 

0.196”

Burner Ports

Problem: Sudden drop in gas flow, or a reduced flame height

Possible Cause 1: 

Out of gas.

-Call your local gas company.

Possible Cause 2:

 Excess flow safety device may have been activated.

-Turn control knob to “OFF”, wait 30 seconds and light outdoor fire table. If flames are still too low reset 

the excessive flow safety device by turning off the control knob and the gas supply. 

Disconnect the quick disconnect socket. 

Turn Burner Control Knob to "HIGH". Wait 1 minute. 

Turn Burner Control Knob off. 

Reconnect the quick disconnect, turn on the main gas supply and perform a leak check at the Natural 

Gas connection.

Содержание Fiery Rock OFG147NG

Страница 1: ...fire or explosion may result causing property damage personal injury or loss of life Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment Save these instructions for future reference If you are assembling this unit for someone else give this manual to him or her to read and savefor future reference Do not store or use gasoline or oth...

Страница 2: ...fornia to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov WARNING This product can expose you to Disononyl phthalate DINP which is known to the Sate of California to cause cancer For more information go to www P65Warnings ca gov WARNING This product can expose you to Butylbenzyl phthalate BBP Di n butyl phthalate DBP which is known to the...

Страница 3: ...s or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NEPA 54 Natural Fuel Gas code Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling code B149 2 This appliance complies with ANSI Z21 97 2017 CSA2 41 2017 Outdoor Decorative Gas Appliances Standards Minimum Clearance from Unit to Combustible Materials 72 182 9cm minus the height of applian...

Страница 4: ...r under overhanging trees and shrubs The use of alcohol prescription or non prescription drugs may impair an individual s abilityto properly assemble or safely operate this outdoor firetable DO NOT use this outdoor fire table if any part has been under water Immediately call a qualified service technician to inspect the fire table and to replace any part or control system and any gas control which...

Страница 5: ...acteristics before using any natural gas product Natural Gas Characteristics Flammable explosiveunder pressure lighter than air and settles in pools in high areas In its natural state natural gas has no odor For your safety an odorant has been added Contact with natural gas could burn the skin Natural gasisextremelyflammableandhazardousifhandledimproperly Chemicals known to the state of California...

Страница 6: ...anual shut off valve at the gas supply WARNING During any high pressure testing of the gas supply piping system at test pressures in excess of psi 3 5 kPa the appliance and its individual shut off valve must be disconnected from the gas supply piping system The outdoor fire table must be isolated from the gas supply piping system by closing the individual manual shut off valve during any pressure ...

Страница 7: ...c 14 Ignitor 1 pc 15 Control Knob 1 pc 16 Control Panel 1 pc 17 Fire bowl 1 pc 19 Lava Rock 12 kgs 20 Cover 1 pc 02 09 07 08 _ WARNING For technical support or replacement parts or missing parts please contact Elementi at 800 678 7294 14 15 16 11 12 13 18 03 04 05 06 06 Orifice 1 pc 07 Air inlet pipe B 1 pc 21 Fire Pit 1 pc 18 Battery 1 pc 19 21 20 01 23 08 22 10 17 22 Fitting 1 pc 23 Touch up kit...

Страница 8: ...w Battery not included 2 Place lava rock by hand DO NOT dump bag out in to the tray to avoid clogging the burner with dust Position the lava rock to a level about 1 above the t op of the burner Make sure that you do not block the igniter box with lava rock to ensure proper ignition ...

Страница 9: ...et is recommended by the National Fuel Gas Code Socket connection must be made outdoors FIREPIT FIREPIT Adjustable feet has pre installed on the bottom of fire pit already Please adjust the hight of feet to make sure all fire pit was on level always or increase the height of fire table as your preference Please make sure the height was safty before you complete ...

Страница 10: ...ipple with gas resistant pipe compound or approved Teflon PTFE tape Screw socket onto gas supply pipe house gas source as shown to the right and wrench tighten The quick disconnect socket should never be connected to the fire table Direction of gas flow is indicated on the socket ...

Страница 11: ...k disconnect socket and insert the unattached end of the gas hose into the socket Release the sleeve and continue pushing the hose into the socket until the sleeve snaps into the locked position After making all connections perform a leak test as described on page 12 of this manual 11 20 ...

Страница 12: ...f you continue to see bubbles after several attempts disconnect natural gas source and contact Elementi at 800 678 7294 for assistance If no bubbles appear after one minute turn source OFF wipe away solution and proceed Check for leaks at these locations WARNING Before using this outdoor fire table make sure you have read understand and are following all information provided in the Important Safet...

Страница 13: ...e lighter near the side of the burner DO NOT lean over the fire table while lighting 3 Turn control knob counterclockwise to LOW 4 Remove long match long butane lighter 5 After lighting use a shovel and heat resistant gloves to carefully move the lava rocks back into their proper position 6 Observe flame make sure all burner ports are lit Flame height should be no higher than 13 inches tall 7 Adju...

Страница 14: ...ergent apply with a soft cloth or Sponge 2 For finger prints or smears use 3M Stainless Steel Cleaner and Polish Arcal 20 Lac O Nu LuminWash O Cedar Cream Polish or Stainless Shine this will provide a barrier file to minimize fingerprints 3 For stubborn stains and discoloration use 3M Stainless Steel Cleaner and Polish Allchem Concentrated Cleaner Samae Twinkle Cameo Copper Cleaner Liquid Nu Steel...

Страница 15: ...correctly connected Both electrode wires must be fully inserted into the igniter box 2 Make sure that the pilot housing is unobstructed Clear any debris on top of the pilot housing and make sure there is no debris between the igniter pin thermocouple and the burner tube CORRECT INCORRECT Igniter Box Thermocouple Wire Igniter Box Valve the inner side ...

Страница 16: ...ure that the thermocouple wire is correctly positioned The thermocouple wire should be in line with the valve Thermocouple Wire 5mm 0 196 3 Make sure that the igniter pin and thermocouple are correctly positioned The igniter pin should be pointed straight to the thermocouple The thermocouple should be positioned 5mm 0 196 away from the burner tube ...

Страница 17: ...Burner will not light with match Possible Cause 1 No Gas Flow Check if Natural Gas supply is stopped If it is not stopped refer to Problem Sudden drop in gas flow on the following page Possible Cause 2 Quick Connect not fully engaged Disconnect the quick connect at the gas supply and reconnect to ensure a proper connection is made Possible Cause 3 Obstruction of gas flow Check for bent or kinked h...

Страница 18: ... Call your local gas company Possible Cause 3 Excess fl ow valve tripped Refer to Problem Sudden drop in gas flow 5mm 0 196 Burner Ports Problem Sudden drop in gas flow or a reduced flame height Possible Cause 1 Out of gas Call your local gas company Possible Cause 2 Excess flow safety device may have been activated Turn control knob to OFF wait 30 seconds and light outdoor fire table If flames ar...

Страница 19: ...ll gas lines must be installed by a licensed gas fitter Damage caused by shipping staining and abuse are not covered under this warranty Dings dents and scratches fading and natural weathering are not covered under this warranty Decorative rock is not covered under this warranty Improper installations repair or modifications made by anyone other than Elementi will void this warranty and any damage...

Страница 20: ...Ocean Rock USA INC 692 Parkridge Ave Norco CA 92860 USA www elementifire com info elementifire com Tel 800 678 7294 ...

Отзывы: