INSTALLATION AND USER MANUAL

1.6  Fire safety

1.6.1 Installation of the PowerFan

Always provide a free space around the PowerFan with a 

minimum of 100mm. Take extra account of distance with regard 

to combustible materials and ventilation. When the PowerFan is 

placed in an enclosure, the necessary ventilation openings must 

be made in the enclosure (See 

Figure 1.8

).

Note: 

Provide the enclosure with at least 2 gratings with a free 

passage of 100mm

2

 per grid.

1.6.2 Flue material

Single-walled flue material must always be covered with non-

combustible building materials. In all other cases, concentric 

flue material must always be used. Concentric flue material can 

also be used, whereby the outer casing serves as an insulation 

and ventilation option for the inner pipe.

Note: 

Please make sure that no heat bridges can occur by 

brackets around the concentric or single-tube material.

Figure 1.8 - Ventilation around PowerFan MkII

Figure 1.7 - Roof terminal supplies

Содержание POWERFAN MKII

Страница 1: ...INSTALLATION USER MANUAL PLEASE LEAVE THIS MANUAL WITH THE FIREPLACE FOR FUTURE REFERANCE P O W E R F A N M K I I...

Страница 2: ......

Страница 3: ...validity when changes to the device are made without written permission of Element4 You can request a copy of the test certificate via info element4 nl Jan Kempers CEO PREFACE Congratulations on the...

Страница 4: ......

Страница 5: ...2 1 Vertical terminal location C11 11 2 2 Horizontal terminal location C31 11 3 FLUE SYSTEM 12 3 1 Flue configurations 12 3 2 Configurations 13 3 3 Calculating the length of the flue 15 3 4 Extra resi...

Страница 6: ...around the PowerFan MkII 1 3 Assembly The PowerFan has three mounting brackets For the PowerFan to function properly it makes no difference how the outlet is positioned Figure 1 2 Make sure the PowerF...

Страница 7: ...s of flue gas pipes Concentric OnTop Metaloterm eg the SU line Jeremias Poujoulat Other flue material that has been tested according to the applicable standards Single walled Flexible tube Rigid tube...

Страница 8: ...t also be taken into account 1 5 1 Distance between outlets Whenopeningintothesamehorizontaloutletarea thefollowing distances must be observed with regard to the outlets of supply air and flue gas dis...

Страница 9: ...the enclosure with at least 2 gratings with a free passage of 100mm2 per grid 1 6 2 Flue material Single walled flue material must always be covered with non combustible building materials In all oth...

Страница 10: ...in pipes 300 E Under eaves 300 F Under balconies or roofs of open garages 600 G From a vertical drain pipe 300 H From an inside or outside corner 600 I Above ground roof or balcony level 300 J From a...

Страница 11: ...lied to a fireplace with a 150 100 flue connection the flue must be increased to 200 130 on the supplied adapter splitter or a separate 150 100 concentric splitter must be used The latter component is...

Страница 12: ...nd B2 is the part after 1 Terminal area 1 2 Terminal area 2 3 2 2 Configuration 2 partial concentric flue configuration In this situation the flue partially is carried out with a regular concentric tu...

Страница 13: ...C 1 A B 2 Figure 3 6 Partial concentric flue configuration with horizontal terminal in a different area B 2 A C B 1 Figure 3 7 Roof terminal with partial concentric flue A B 1 B 2 Figure 3 4 Roof term...

Страница 14: ...charge can be 30 meters In figure 3 11 to 3 13 You will see three options that fall under type 2 Each option is explained further below Flue lengths for construction type 2 1 Maximum length of the con...

Страница 15: ...ximum length of your split supply and discharge Flue lengths construction type 2 3 Partial Concentric flue flue size 150 100 See Figure 3 13 In this situation a part of the flue is executed concentric...

Страница 16: ...that can offer extra resistance to your flue Figure 3 14 Q bends both 90 and 45 are calculated as a 0 5 meter discharge length Positive N bends both 90 and 45 are calculated as a 0 25 meter discharge...

Страница 17: ...length K If L is less than or equal to the desired length you can install your flue configuration without any problems Step 4 Add K and L to determine the full length of your flue For K and L together...

Страница 18: ...5 10 m Or read L from table 3 2 at K 15m For K 15 m the value L 10 m is also shown in the table Because the flue outlet is longer than the air supply calculated from the adapter we check whether this...

Страница 19: ...e flue so that the water can flow away at any time The condensate can be collected in for example a siphon cup or a condensate collector T shaped with tap as shown in figures 3 16 and 3 17 parts 1 and...

Страница 20: ...LED is blinking The fan checks the system for correct operation for 60 seconds If the system works properly the blinking stops and the LED stays green LED flashes red If the green light does not stop...

Страница 21: ...pressing the Start button top left buttom the fireplace and the PowerFan will start simultaneously Note The thermostat and pilot flame function are canceled with installations in combination with a Po...

Страница 22: ...INSTALLATION AND USER MANUAL 23 7 TECHNICAL DRAWINGS 90 61 2 100 151 20 50 201 2 100 1 0 0 2 0 0 1 3 0 2 0 0 Figure 7 1 Dimensions of the adapter...

Страница 23: ...INSTALLATION AND USER MANUAL 24 137 108 137 175 206 5 99 245 323 275 80 Figure 7 2 Dimensions PowerFan MkII...

Страница 24: ...Paxtonstraat 23 8013 RP Zwolle The Netherlands Info element4 nl www element4 nl RELEASE DATE 09 07 19 ELEMENT 4 B V...

Отзывы: