INSTALLATIEHANDLEIDING
18
3.5 Sample flue configuration calculation
Step 1
Consider which flue configuration is required
Step 2
Calculate the length of the desired concentric part (
C
) of your
configuration.
Note:
Do not forget to include the bends and negative flue in
your calculation.
Step 3 - option a
Then calculate the desired lengths from supply to the adapter
(
A
) and discharge from the adapter (
B
1
) and (
B
2
). For your
convenience, always choose the longest of both. So you only
have to calculate the length once.
Enter the formula "
L
= 20 - 2/3 *
K
" to see how long your supply
and removal can be.
•
K
is the length of your concentric part.
•
L
is the maximum length of the supply and discharge
Step 3 - option b
Check whether the discharge lengths for the supply to - and
the discharge from the adapter are permitted with the desired
concentric length, by reading in
table 3.2
the maximum length
of the remaining air supply / flue gas discharge (
L
) corresponding
to the desired concentric length (
K
).
If
L
is less than or equal to the desired length, you can install
your flue configuration without any problems.
Step 4
Add
K
and
L
to determine the full length of your flue.
For
K
and
L
together, this distance may never be longer than 30
meters and the Powerfan should be always minimum of two
meters away from the fireplace (distance
B
1
).
K
L
K
L
K
L
0 m
20 m
10,5 m 13
m
20,5 m 6,25 m
1 m 19,25 m
11 m 12,5
m
21 m
6 m
1,5 m
19 m
11,5 m 12,25 m
21,5 m
5,5 m
2 m
18,5 m
12 m 12
m
22 m 5,25 m
2,5 m 18,25 m
12,5 m 11,5
m
22,5 m
5 m
3 m
18 m
13 m 11,25 m
23 m
4,5 m
3,5 m
17,5 m
13,5 m 11
m
23,5 m 4,25 m
4 m 17,25 m
14 m 10,5
m
24 m
4 m
4,5 m
17 m
14,5 m 10,25 m
24,5 m
3,5 m
5 m
16,5 m
15 m 10
m
25 m 3,25 m
5,5 m 16,25 m
15,5 m 9,5
m
25,5 m
3 m
6 m
16 m
16 m 9,25
m
26 m
2,5 m
6,5 m
15,5 m
16,5 m 9
m
26,5 m 2,25 m
7 m 15,25 m
17 m 8,5
m
27 m
2 m
7,5 m
15 m
17,5 m 8,25
m
27,5 m
1,5 m
8 m
14,5 m
18 m 8
m
28 m 1,25 m
8,5 m 14,25 m
18,5 m 7,5
m
28,5 m
1 m
9 m
14 m
19 m 7,25
m
29 m
0,5 m
9,5 m
13,5 m
19,5 m 7
m
29,5 m 0,25 m
10 m 13,25 m
20 m 6,5
m
30 m
0 m
Table 3.2 - Permitted lengths for air supply and flue gas
discharge L at concentric stretch K