INSTALLATIEHANDLEIDING
7
1 INSTALLATION
1.1 Delivery check
Note:
Check the PowerFan for transport damage before first use
and report any damage to your supplier immediately.
Make sure the following parts are included
•
PowerFan MkII
•
PowerFan module
•
PowerFan module connection cables
•
220 volt connection cable
•
Adapter / splitter
•
2x Wall terminal Ø100mm
•
Installation manual
1.2 Points of attention during installation
Note:
The PowerFan must be accessible at all times for service
and inspection. It should be mentioned here that the regular
service hatch of Element 4 (BDLE4) is not sufficient for the size of
the PowerFan MkII. The installer must make a provision for this
himself.
Figure 1.1
.
It is recommended that the PowerFan MkII be placed in a room
that is large enough for the PowerFan to be removed without
having to interrupt the conversion.
Avoid extreme, wind-sensitive positions for the flue gas outlet,
since this can lead to annoying shutdowns of the system (See
also
CHAPTER 2
).
NB:
A minimum distance of two meters from the fireplace is
required to prevent the fan from malfunctioning.
The PowerFan does not require any additional maintenance, but
an annual inspection is recommended. Provide the installation
with removable connections on the PowerFan. This facilitates
the disassembly of the motor or circuit board.
Figure 1.1 - Service area around the PowerFan MkII
1.3 Assembly
The PowerFan has three mounting brackets. For the PowerFan
to function properly, it makes no difference how the outlet is
positioned
(Figure 1.2)
.
Make sure the PowerFan brackets are not tightened too tightly to
prevent resonance of the casing, for unnecessary noise.
Note:
Preferably use rubber vibration dampers (not supplied
by Element4) between the PowerFan and the wall to prevent
resonance.
The inside of the fan is equipped with rubber suspension for
more flexibility.
1.3.1 Mounting PowerFan Module
The module ensures that communication can occur between the
fireplace and PowerFan. The cable required for this is supplied
with the PowerFan. See
Figure 1.3
.
When the PowerFan is not connected to the receiver of the
fireplace, it will function as a regular fan when connected to the
socket. It is therefore important to check that the PowerFan is
correctly connected. When the fire is off, the fan must also be off.
1.3.2 Assembly flue material
Ensure that all connections of the individual flue parts are closed.
Leakage will adversely affect the operation of the PowerFan and
cause the fire to switch off.
Note:
Element4 cannot be held liable for leaks of flue poured
into concrete or buried flue.
1.3.3 Power connection
The PowerFan is equipped with a service plug. For the power
supply, a 230VAC - 50Hz wall socket must be mounted within a
range of 1 meter from the PowerFan.
1.3.4 PowerFan cable
The cable must not come into contact with the flue material. The
standard length is 20 meters, this can be replaced by a longer
cable.