12
INSTALLATION AND USER MANUAL
3 FLUE SYSTEM
3.1 Flue configurations
The PowerFan MkII is a very flexible solution for difficult flue
situations for all Element4 fireplaces. By making use of a
separate air supply and flue gas discharge, you can achieve the
desired flue situation in many ways.
In this chapter these different options are explained, in what
ways the flue situation can be carried out.
The following applies to all construction options in
chapter 3.2
(see also accompanying
figures 3.2
to
3.8
):
•
A
= Combustion air supply channel
Pipe diameter A is Ø100 mm
•
B
1
= Flue gas outlet
Pipe diameter
B
1
is Ø100 mm
•
B
2
= Flue gas outlet
Pipe diameter B2 is Ø80 mm
•
C
= Concentric channel
Diameter is Ø200/130 mm or Ø150/100 mm
Note:
In the event that a PowerFan MkII is applied to a fireplace
with a Ø150/100 flue connection, the flue must be increased
to Ø200/130 on the supplied adapter / splitter or a separate
150/100 concentric splitter must be used . The latter component
is not provided by Element4. (
Image 3.1
and
table 3.1
)
(1)
= Terminal area 1
(2)
= Terminal area 2
Chapter 3.3
explains how the above-mentioned lengths can be
calculated for each construction situation.
Because not every flue configuration is completely straight,
bends must often be used. When the PowerFan MkII is used, the
flue configuration is often a special case.
Chapter 3.4
explains
the effect of the bends and also of a negative flue on the length
of your flue configuration.
In
chapter 3.5
you will find a calculation method for calculating
the flue configuration. Where necessary, you can always consult
the manufacturer in exceptional situations.
Ø
1
Ø
2
Ø
3
Ø
4
Figure 3.1 - Adapter 200/130
Adapter 200/130
Ø1
Ø 100 mm
Ø2
Ø 200 mm
Ø3
Ø 100 mm
Ø4
Ø 130 mm
Table 3.1 - Measurements adapter