INSTALLING THE GAS LINE
Correctly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed as per
requirements outlined in the latest edition of the National Fuel Gas Code, NFPA 54 (USA) or CAN/CSA-B149.1 (Canada).
Never use galvanized or plastic pipe unless specified for use with gas. Refer to the table below for proper sizing of the supply gas
line. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. A
qualified plumber or gas fitter should be hired to correctly size and route the gas supply line to the appliance.
Installing a gas supply line from the fuel supply to the appliance involves numerous considerations of materials, protection, sizing,
locations, controls, pressure, sediment trap, and other criteria. The sizing and/or installing of gas piping should only be performed
by a qualified plumber or gasfitter.
The gas control inlet accepts a 3/8” NPT fitting.
Schedule 40 Black Iron Pip
e
Natural
Gas
Propane
Gas
Length (feet) Inside Diameter (Inches)
0 - 10
1/2
3/8
10 - 40
1/2
1/2
40 - 100
1/2
1/2
100 - 150
3/4
1/2
150 - 200
3/4
1/2
Table 4
ELECTRICAL REQUIREMENTS
The Element4 fireplaces use a receiver and remote control for their burner operation. The remote control comes with (3) AAA
batteries and the receiver is powered by a 120V AC adapter, included.
The installer must provide an approved 120V AC wall receptacle to be placed within the six foot cord limit of the AC adapter.
The receiver may be powered by
either
the AC adapter
or
(4) AA batteries -
not both.
Batteries do not provide an electrical
backup for the AC adapter. Using batteries in combination with the AC adapter can damage the receiver.
Electrical work must be performed by a qualified, licensed electrician.
All wiring shall be in compliance with all local, city, and state codes.
WARNING
This fireplace arrives from the factory for use with natural gas. See Appendix Three for LP (propane) conversion instructions.