CLEARANCES
Element4 Gas Fireplaces
European
Home
.com
B
The total area of the convection air outlet(s) depends on the fireplace model. The location of the outlet(s) must allow for the free
movement of air and must not allow excessive convection air to build up within the chase. The top of the outlet(s) must be at least
1”/25 mm down from the ceiling and we recommend no more than 3”/76
mm
down. The minimum distance from the bottom of the
appliance to the room ceiling is 72”/1830
mm
.
A
TYPICAL CLEARANCE DIAGRAMS
Figure 18
Convection
Air Outlet
Minimum Distances
A
Room ceiling to
appliance bottom
72”
1830
mm
B
Room ceiling to top of
Convection Air Outlet
1”
25
mm
Table 2
Convection Air Outlet Area by Model
Model
Square
Inches
Square
Centimeters
Modore 95
50
322
Bidore 95
50
322
Trisore 95
50
322