36
F. Electronics keep sparking while the
pilot burner is ignited
G. Pilot burner is burning, but mag-
netic valve closes after ca. 10 seconds
or when the appliance gets hot
H. There are short sound sig- nals,
but no sparks and no sound / clicks
can be heard of the magnet opening
the valve
I. Pilot burner is burning, but there is
no gas flow to the main burner
J. Main burner ignites, but goes out
again after approx. 22 seconds
1. Receiver is damaged.
1. Thermocouple does not function.
2. Batteries (almost) empty.
1. Batteries (almost) empty.
1. Button A in position MAN.
2. Appliance in the pilot flame posi-
tion.
3. Pre-pressure of the gas is too low.
4. Damaged magnetic valve.
1. Wiring of 2 nd thermocouple* is
loose.
2. Wires of 2 nd thermocouple *
have been cross-connected.
3. Short-circuit in the wiring of ther-
mocouple
4. Broken wire in the wiring of 2nd
thermocouple *
5. Thermocouple is dirty.
6. 2 nd Thermocouple* is not posi-
tioned correctly in the flame
7. Thermocouple is defective.
8. Receiver is defective.
* on certain models
*
1. Replace the receiver and confirm
the code
(remedy 1 at A)
1.1 Measure the voltage, using a
digital mul- timeter, set to mV range,
by connecting the cables to the cable
shoe. The cable shoe is located on the
outside, directly next to the magnet nut
at the rear of the gas control;
The voltage should be at least 5mV
within
20 seconds.
It may not be lower when the appli-
ance is warm.
If the voltage is too low:
- the thermocouple should be placed
bet- ter in the flame or
- the thermocouple should be re-
placed.
1.2 Check the size of the pilot burner
flame.
Correct a flame that is too small.
1.3 Check the wiring of the thermo-
couple to the receiver.
If necessary, replace the wiring.
2. Replace the receiver’s batteries.
!Caution Avoid short circuit between
the batteries and metal parts of the
appliance.
1. Replace the receiver’s batteries.
!Caution Avoid short circuit between
the batte- ries and metal parts of the
appliance.
1. Turn button A on the gas control to
ON
2. Increase the flame height by press-
ing button (large flame) on the remote
control.
3. Check pre-pressure.
If necessary, contact gas company.
4. Replace the gas control.
1. Connect the wiring properly.(figure
2)
2. Connect the wiring properly. (figure
2)
3. Replace wiring.
4. Replace wiring.
5. Clean the thermocouple.
6. Position the thermocouple cor-
rectly in the flame.
7. Check the voltage across thermo-
couple just before the main burner
goes out.
If the voltage is lower than 1.8 mV, re-
place thermocouple
8. Check the voltage across thermo-
couple just before the main burner
goes out.
If the voltage is higher than 1.8 mV,
replace the receiver.
“Problem”
“Possible cause”
“Remedy”
TROUBLE SHOOTING
Содержание Bidore 140
Страница 15: ...15 INSTALLER INFORMATION 15 INSTALLER INFORMATION ...
Страница 16: ...16 INSTALLER INFORMATION 16 INSTALLER INFORMATION ...
Страница 17: ...17 INSTALLER INFORMATION 17 INSTALLER INFORMATION ...
Страница 18: ...18 INSTALLER INFORMATION 18 INSTALLER INFORMATION ...
Страница 30: ...30 INSTALLER INFORMATION 30 INSTALLER INFORMATION ...
Страница 45: ...45 TECHNICAL INFORMATION 45 TECHNICAL INFORMATION PIN 0359CN1268 PIN 0359CN1268 Modore 140 ...
Страница 47: ...47 ...
Страница 48: ...Element4 B V Paxtonstraat 23 8013 RP Zwolle The Netherlands September 2014 ...