INSTALLER INFORMATION
Terminal Locations Roof Termination
“Distance” = minimum distance required for positioning of the outlet to avoid adverse effects
with respect to:
A. A ventilation opening serving an occupied room, a toilet or a bathroom
B. A heating air supply, when the supply flows through an occupied room.
C. A window that can be opened and that is near an occupied room, a toilet or a bathroom.
(*)
If the required distance cannot be achieved, the outlet position rules take precedence.
(**) If the outlet is positioned at least 1 m higher than the intake supply opening, or a window
that can be opened.
(***) If the required distance cannot be achieved, the position of the outlet must be at least 1 m
above the highest facade/roof.
Important note for Roof Terminations (C31).
When installing the appliance with a roof termination (classification C31), it is important to fit a
flue restriction strip across the flue outlet inside the stove, see following notes.
Minimum Vertical Length notes.
Roof terminations may be installed from a minimum height 1.0 m this is shown on the pages that
follow.
To avoid adverse effects
Distance: outlet -
A,B or C
At the same roof level
>6 m (*)
At a different roof level
>3 m (*) (**)
At a lower positioned wall
>2 m (**)
At a higher sloping surface
>6 m (***)
Содержание Bidore 140
Страница 15: ...15 INSTALLER INFORMATION 15 INSTALLER INFORMATION ...
Страница 16: ...16 INSTALLER INFORMATION 16 INSTALLER INFORMATION ...
Страница 17: ...17 INSTALLER INFORMATION 17 INSTALLER INFORMATION ...
Страница 18: ...18 INSTALLER INFORMATION 18 INSTALLER INFORMATION ...
Страница 30: ...30 INSTALLER INFORMATION 30 INSTALLER INFORMATION ...
Страница 45: ...45 TECHNICAL INFORMATION 45 TECHNICAL INFORMATION PIN 0359CN1268 PIN 0359CN1268 Modore 140 ...
Страница 47: ...47 ...
Страница 48: ...Element4 B V Paxtonstraat 23 8013 RP Zwolle The Netherlands September 2014 ...