background image

8

Chapter 6 

I N S T A L L A T I O N   M A N U A L   |

FIRE SAFE INSTALLATION

To  install  a  gas  fireplace  as  safely  as  possible,  several  installation 

preparations need to be made. This overview can be used to assure the 

fire safety of a conversion of a fireplace.  

6�1 

FIRE SAFETY DEVICE SET-UP

Install the device such that there are no flammable materials around the 

device or chimney. 

Flammable  materials,  such  as  wood,  can  combust  at  a  temperature  of 

85°C. At high temperatures this can happen within several minutes (over 
200°C) or at lower temperatures (more than 85°C) this may occur over a 
period of weeks.  

A gas fireplace can achieve temperatures of over 200°C. Therefore one 
should  use  only  non-flammable  materials  around  the  fireplace  and  in 

the cove. 

It is important to follow the installation regulations below carefully. When 

the regulations are insufficiently- or not provided with the aspects of fire 
safety, the instructions according to NPR 3378-20:2010 are leading. 

6�2 

ASSEMBLY REGULATIONS 

6�2�1 

GENERAL ASSEMBLY REGULATIONS 

• 

Load-bearing walls and ceilings must be covered in a protective fire 

resistant plate. 

• 

Never use flammable materials around the fireplace or cove. The 
minimal distance between the device and non-flammable materials 
must be at 50 mm to ensure a convection air flow, also see 

section 

14.3.4

.  The  frames  around  the  fireplace  take  into  account  this 

distance. 

• 

Non-combustible materials may be installed to a zero clearance to 

the outer faces of the appliance outer frame face, given they not 

cover or prevent the removal of the glass panels or other parts of 

the fireplace that need to be removed during maintenance. 

• 

The entire weight of the walls must be borne by a structure other 

than the fireplace.

6�2�2 

ASSEMBLY REGULATIONS FOR NON-FLAMMABLE MATERIALS

(

Figure 6.1

  | and 

Figure 6.2

 |) 

• 

Make sure there is a good air ventilation in the cove. The 
temperature that leaves through the ventilation grilles must not be 
higher than 85°C. Therefore one should always make sure there are 
enough ventilation grilles in the upper and lower parts of the cove. 

6�2�3 

ASSEMBLY REGULATIONS WITH FLAMMABLE MATERIALS

For reference see 

Figure 6.3

  | and 

Figure 6.4

  | on the next page. 

• 

Cover the walls/ceilings with a non-flammable, fire resistant plate, 

according to EN 13501-1:A2

• 

Place a non-flammable, fire resistant plate in front of the first one at 

a distance of 20mm or more.  

• 

Make sure that the two plates are not attached to each other by 
screws or nails. Due to their conductivity these metals can cause a 

heat bridge throught which a fire may occur over time! 

6�3 

OTHER RULES REGARDING HEAT IN YOUR INSTALLATION 

6�3�1 

FLOOR PROTECTION

Between the device and the ground a minimal distance of 10cm is to be 

taken into account. The temperature of the floor under the device needs 
be less than 85°C and the floor of the conversion around the fireplace 
is to be constructed of non-flammable materials. If necessary the floor 

is to be covered with an insulation layer to protect it from unauthorized 
temperatures.  

It is also allowed to position the fireplace on an elevated platform. The 
platform also needs to meet the requirements for a safe installation. 

6�3�2 

ELECTRICAL  PIPES 

The conversion has to be free of the usual electric installation pipes, if 

these are not protected against temperatures over 30°C by the necessary 
precautions. Special pipelines with an heightened heat resistance are 
permitted. 

6�3�3 

OUTDOOR INSTALLATION 

This appliance is meant for indoor use. In the case that an Element4 

appliance is to be installed as part of an indoor outdoor construction, 
or  anywhere  in  direct  contact  with  outdoor  circumstances,  a 

number of safety precautions are to be taken into account. 

 

For more information on an (semi-)outdoor installation of an Element4 

product please contact your dealer.

6�4 

TOPSIDE FRAME

The  fireplace  needs  to  be  installed  with  a  sturdy,  non-flammable  top 
frame. The Frame needs to support the topside of the fireplace and any 
flue  material  resting  on  it.  The  topside  of  the  fireplace  is  33kg.  If  the 

frame deforms it might be impossible to remove the window panes. 

The  fireplace  is  provided  with  instaltion  brackets.  After  palcing  the 
bottom part use the installation brackets to fix te heigth of the top part. 

Attach the top part to the frame and use the bolts to adjsut the heigth. 
Only after the topside is securly fastened the installation brackets can 
be removed and the windows placed. 

Attention

:  The  installation  brackets  need  to  be  removed  before  the 

build-in trims can be mounted.

Содержание ARCHITECT Series

Страница 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device A R C H I T E C T S E R I E S...

Страница 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Страница 3: ...LY REGULATIONS 8 6 2 1 GENERAL ASSEMBLY REGULATIONS 8 6 2 2 ASSEMBLY REGULATIONS FOR NON FLAMMABLE MATERIALS 8 6 2 3 ASSEMBLY REGULATIONS WITH FLAMMABLE MATERIALS 8 6 3 OTHER RULES REGARDING HEAT IN Y...

Страница 4: ...ST AID FOR MALFUNCTION 19 A B NECESSARY TOOLS 23 B ERRORS CODES PROCONTROL APP 24 B A MESSAGES SHOWN IN APP 24 B B MESSAGES SHOWN IN REMOTE 25 C FAULTS AND ERROR CODES IN THE REMOTE 26 C A F41 ERROR 2...

Страница 5: ...o the device Make sure it is accessible at all times This device may not be used a primary heat source This device is designed to be used with natural gas or LPG The device can only be used with the t...

Страница 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Страница 7: ...ON 1 2 OFF Figure 3 1 Remote and ignition sign Figure 3 2 Gas Block Figure 3 3 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figur...

Страница 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Страница 9: ...on the next page Cover the walls ceilings with a non flammable fire resistant plate according to EN 13501 1 A2 Place a non flammable fire resistant plate in front of the first one at a distance of 20...

Страница 10: ...Example of isntalation with flue A a a C E B D Figure 6 1 Distancer to non flammable materials front A A a a A A Figure 6 2 Distance to flammable materials Letter Distances to flammable materials mm...

Страница 11: ...radation 7 2 2 REFERENCE THE FLUE CALCULATION In order to ascertain whether your intended extraction shall function properly a stove category is determined After you have determined the applicable cat...

Страница 12: ...strictor Position 7 5 INSTALLATION OF FLUE MATERIAL Follow the following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit with a 150 mm diameter f...

Страница 13: ...lity of the app is to pre set the temperature of you device for a period of one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames a...

Страница 14: ...Then lower it further next to the fireplace till it is clear of the top bracket before putting it away See Figure 9 2 Carefully take out the corner glasses by pulling them outward a bit lifting them a...

Страница 15: ...9 INSTALLATION MANUAL 3 1 2 Figure 9 2 Outer window placement method reverse order for removal A B C D E F 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 Figure 9 3 Remove Corner Glass Figure 9 4 Remove Inner glass...

Страница 16: ...this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 3 2 PILOT The pilot flame...

Страница 17: ...dling these materials 10 1 DECORATION ARRANGEMENT The archtect series uses a collection of eigth different ceramic flowers see Figure 9 1 for decoration Only the decoration ceramics supplied with this...

Страница 18: ...flower 6 small open rose four times flower 7 small closed poppy and four times flower 8 tulip Figure 10 2 Locations pilot and thermocouple 8 8 8 8 1 2 2 2 1 1 3 3 3 Figure 10 3 Flower placement part 1...

Страница 19: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Страница 20: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Страница 21: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Страница 22: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Страница 23: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Страница 24: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Страница 25: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Страница 26: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Страница 27: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Страница 28: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Страница 29: ...V V V V 2 V V V V V X 1 5 V V V V X X 1 V V V X X X 0 1 2 3 4 5 Total Horizontal Section Total vertical Section 22 V X X X X X X 21 O V X X X X X 20 O O V X X X X 19 O O O V X X X 18 O O O O V X X 17...

Страница 30: ...e C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode elsb 9 5 kW Power requirement for the permanent pilot light Power req...

Страница 31: ...with an eco label which is always supplied with the fireplace The ecolabel shows which category the fireplace belongs to G A ECOLABELS The ecolabels for the different types of gas are indicated below...

Страница 32: ...NGS On this page you will find the dimensional drawings of the Architect Series with some of the important dimensions that you have to take into account when installing and installing your fireplace F...

Страница 33: ...Info element4 nl www element4 nl 24 01 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...

Отзывы: