2 9
Appendix F
I N S T A L L A T I O N M A N U A L |
Gas type »
NATURAL GAS
LPG
Country of use »
AT,BG,CH
DK,ES,FI
GB,GR,HR
IE,IT,LT
LV,NO,PT
RO,SE,SI
SK,TR
DE,LU
PL
BE,FR
DE
NL
BG,DK,EE
FI,GB,GR
HU,HR,IT
LY,MT,NL
NO,RO,SE
SI,SK,TR
CZ,LT
NL,SK
AT,CH
CZ,DE
AT,BE,CH
CZ,DE,ES
FR,GB,IE
IT,NL,PT
SK,TR
Gas Category »
I2
H
I2
E
I2
E+
I2ELL
I2
L
/ I2
EK
I3
B/P
I3
p
I3
P
I3+
Unit
G20
G20
G20/G25
G20/G25
G25/G25,3
G30/G31
G30
G31
G30/G31
Supply pressure
mbar
20
20
20 / 25
20
25
30
30
50
28 -
30/37
Burner pressure
mbar
15
15
15 / 21
15.0
21
28
28
28
28
Gross input
kW
13,5
13,5
13,5 / 12,6
13,5
13
15,5
13.5
15
15
Net input
kW
12,2
12,2
12,2 / 11,3
12,2
11,3
14
12.2
13,5
13.5
max. Heat
output
kW
10,9
10,9
10,9 / 10,1
10,9
10,1
12,4
10.8
12
12
min. Heat output
kW
2,7
2,7
2,7 / 2,4
2,7
2,4
2,9
2,8
2,9
2,9
(Max.) Gas usage
m
3
/hr
1.3
1.3
1.3 / 1.45
1.3/1.45
1.45
0.53
0.48
0.53
0.53
kg/hr
0.9
0.9
0.9/1.1
0.9/1.1
1.1
1
0.9
1
1
NOx
mg/kWh
input
<100
<100
Pilot
440-1650-312
440-1350-271
Burnerinjection
4x 280
4x 120
Type of flue
C11 / C31 / C91
Additional electricity use
•
At rated heat output
el
max
9
-5
kW
•
With minimal heat emission
el
min
9
-5
kW
•
In standby mode
el
sb
9
-5
kW
Power requirement for the permanent pilot light
Power requirement for the permanent pilot
light (requirements applicable)
P
pilot
Does not
apply
Efficiency (NCV)
•
Efficiency at rated heat output
η
th, nom
83 %
•
Efficiency at min. heat output (indicative)
η
th, min
54 %
Type of heat release / control room temperature (Select one)
•
With electronic control of the room temperature plus week
switch
Other control options
•
Control of the room temperature with presence detection
•
Control the room temperature with open window detection
•
With the option of remote control
•
With adaptive control of the start
•
With limitation of the operating time
Glass Dimension
Inside glass
611 x 538.5 x 4 (HxWxD)
Outside glass
627 x 691 x 5 (HxWxD)
Corner glas
625 x 86.75 x 5 (HxWxD)
F
TECHNICAL DATA
The dataplate specifies for which type of gas, gas pressure and for which
country this appliance is intended. The nameplate is attached to a chain.
It must remain attached to the chain.
Note:
Check whether the appliance is suitable for the gas type and gas
pressure on site.