Elektror S-MF 345/30 Скачать руководство пользователя страница 16

16

EN

Operating and assembly instructions S-MP

www.elektror.com

9016319 01.20/09

Also make sure that no other dangerous situation can arise 

when restarting after a standstill, e.g. as a result of a power 

failure or blockages.
Cleaning or maintenance must not lead to damage or modi-

fi

 cations to the device and its components that would in

fl

 u-

ence safety or health protection and, for example, impair the 

balanced state of the impeller.
When starting up the blower, make sure that all tools or other 

foreign objects have been removed from inside the device 

and that all covers and protective grilles have been attached 

correctly.

6 SAFETY-RELATED INFORMATION 
ON DECOMMISSIONING AND 
DISMANTLING

The disconnection of all electrical connections and any other 

electrical work in connection with decommissioning must 

only be carried out by a quali

fi

 ed electrician.

The device should be dismantled only when all rotating parts 

have come to a standstill and cannot be restarted.

The guidelines set out in 2.1 Transport and Handling must be 

observed when dismantling and removing it.

Treat the device as industrial waste when disposing of it.

The device parts are made of recyclable material, such as 

aluminium, (stainless) steel, copper and plastic. However, 

there are components that need special treatment (e.g. fre-

quency converters). The statutory national and local disposal 

and recycling regulations must be observed.

7 LIABILITY AND DISCLAIMER

The owner shall bear the responsibility for the correct use of 

the device. 
Elektror shall not accept any liability for any use of its prod-

ucts and components which is contrary to their intended use.

This shall also apply in particular to use in special applica-

tions and under operating conditions that have not been spe-

ci

fi

 cally agreed with Elektror. 

Elektror shall not accept any liability for any modi

fi

 cations or 

alterations to the device or accessories supplied.
Likewise, Elektror shall not be liable for improper, delayed, 

neglected maintenance. Neither shall it be liable for any 

cleaning and repair work not carried out by quali

fi

 ed Elektror 

specialists, nor for the possible consequences.

Содержание S-MF 345/30

Страница 1: ...or de www elektror de S MP S MP 250 25 S MP 280 30 S MP 345 20 S MP 345 30 S MP 375 27 S MP 425 24 S MP 425 31 S MP 450 35 S MP 450 46 S MP 500 45 S MP 540 60 S MP 600 54 S MP 670 47 S MP 710 70 Elekt...

Страница 2: ...ht zul ssig Die maximale Temperatur des F rdermediums darf bei der Serienausf hrung 20 C bis 80 C nicht berschreiten Son derausf hrungen mit Temperatursperre bis max 300 C Eine Reihen oder Parallelsch...

Страница 3: ...itzenschalldruckpe gel von 135 dB C einen Geh rschutz w hrend des Betriebs Bei Nichtbeachtung sind Geh rsch den die Folge Die vom Ventilator abgestrahlten Ger usche sind nicht ber den gesamten Leistun...

Страница 4: ...andhaltung oder nicht abgestimmtem Austausch von Bauteilen f hrt zu nicht bestimmungsgem em Gebrauch und zum Verlust der Ge w hrleistung Das entstehende Risiko tr gt der Kunde oder Betreiber alleine 3...

Страница 5: ...max 1300 Vpk f r Antriebsmotoren gr er 0 75 kW an den Motorklemmen m ssen geeignete Ma nahmen wie z B ein Motorfilter zum Schutz des Motors installiert werden Bitte wenden sie sich diesbe z glich an d...

Страница 6: ...direkt aufgebautem Frequenzumrichter erf llen unter Ber cksichtigung der EMV Hinweise des Frequenz umrichterherstellers und den Angaben in der Elektror Be triebs und Montageanleitung die Anforderunge...

Страница 7: ...verursachen prin zipbedingt Ableitstr me 3 5 mA Diese Ableitstr me k n nen zu Fehlausl sungen in Anlagen f hren die ber einen 30 mA FI Schutzschalter abgesichert sind Im Fehlerfall k nnen Fehlerstr me...

Страница 8: ...nderungen am Ger t und seinen Bestandteilen f hren die Sicherheits oder Gesundheitsschutz beeintr ch tigen und d rfen z B den Wuchtzustand des Laufrades nicht verschlechtern Stellen Sie vor Wiederinbe...

Страница 9: ...ist so lange untersagt bis festgestellt wurde dass die Maschine in die die unvollst ndige Maschine eingebaut werden soll den Bestimmungen der Maschinenrichtlinie 2006 42 EG entspricht Die folgenden ha...

Страница 10: ...to 80 C with the standard model Special models with a temperature limit up to max 300 C Series connection or parallel connection of fans is only pos sible after consultation with Elektror The blower i...

Страница 11: ...d in certain unfavourable cases we recommend that the owner takes measurements The owner must provide sound insulation so that the maximum values permitted by law are not exceeded at the workstations...

Страница 12: ...ding to ISO 14694 2003 E category BV 3 Rigidly mounted mm s Flexibly mounted mm s E ective value r m s E ective value r m s At installation Start up 4 5 6 3 Alarm 7 1 11 8 Shut down 9 0 12 5 Standard...

Страница 13: ...the motor and frequency converter in the above cases must be suitable shielded cables laid using the shortest route and without clamping and plug in connections and connected correctly at both sides...

Страница 14: ...valuation device with motors fitted with a resistor sensor or frequency converter surge protection with FC applications With blowers that cannot be used over the whole character istic curve the motor...

Страница 15: ...must only be carried out by appropriately qualified persons who undergo regular training The following must be ob served in addition to the operating instructions of the respec tive device as well as...

Страница 16: ...arted The guidelines set out in 2 1 Transport and Handling must be observed when dismantling and removing it Treat the device as industrial waste when disposing of it The device parts are made of recy...

Страница 17: ...t permitted until it has been verified that the machine in which the partially completed machine is to be installed complies with the provisions of the Machinery Directive 2006 42 EC The following har...

Страница 18: ...rating plate and blower type rating plate Geh usestellungen Die Geh usestellung des Ventilators ist f r die Bestellung einiger Ersatztei le entscheidend Bestellen Sie Ersatzteile zur Drehrichtung pas...

Страница 19: ...ew 12 Geh usedeckel Housing cover 13 Schraube Screw 14 Einlaufd se Inlet nozzle 15 Schutzgitter Protective grille 16 Schraube Screw 17 Motorkonsole Motor console 18 Ventilatorfl ansch mit Fu Blower fl...

Страница 20: ...0 3000 2905 230 400 50 4 00 2 30 1 1 33 5 79 84 6204 6204 IE3 32 0 3300 3490 230 400 60 4 55 2 65 1 32 33 5 76 83 NEMA 3 32 0 3200 3490 277 480 60 3 80 2 20 1 32 33 5 76 83 S MP 425 31 IE3 36 0 3250...

Страница 21: ...eed Voltage Frequency Power consump tion Motor output Weight Min max sound pressure level LA 1 Ball bearing designa tion 2 m min Pa min 1 V Hz A kW kg db A S MP 540 60 5 5 kW IE3 48 0 5500 2940 400 50...

Страница 22: ...energy e ciency m3 min Total pressure di erence at optimal energy e ciency Pa Revolutions per minute at optimal energy e ciency Specifi c relationship Information to simplify disassembly recycling or...

Страница 23: ...54 1 07 5 5 6 73 4 B 1 73 3 2 3 4 60 11 44 77 0 7350 3566 1 07 5 5 6 72 7 B 1 71 8 2 3 4 S MP 710 70 50 24 20 128 0 8160 2952 1 08 5 5 6 74 8 B 1 74 1 2 3 4 60 20 02 94 5 9507 3558 1 08 5 5 6 1 total...

Страница 24: ...m Internet unter www elektror de Gerne steht Ihnen auch unser Produktmanagement unter der Rufnummer 49 711 31973 1111 zur Verf gung You will find further information about our products on the internet...

Отзывы: