Resistance Welder MULTISPOT MI-100
Operation
30
Exchanging electrode arms
Fig.30: Unbolting electrode arm
1.
To unbolt the electrode arm, use the Allen key provided for that
purpose (Fig.30).
Fig.31: Removing the electrode arm.
2.
Remove the electrode arm simply by pulling it out.
(Fig.31).
3.
Insert the new electrode arm and bolt down.
Exchanging electrode caps
Fig.32: Exchanging electrode caps
1.
To loosen the electrode caps, use the special key provided for
that purpose (or some equivalent tool) (Fig.32).
2
. Turn clockwise, otherwise the cone comes loose.
3.
Put the new caps on the electrode head and press in position.
NOTE!
The perfectly sound condition of the caps is
essential for good welding results.
Electrode caps must be milled (or replaced) after
maximum 50 welding jobs, especially when
working with high strength and/or galvanised steel.
Deploying the electrode arm
Fig.33: Unlocking the arm
1.
Switch the locking device of the electrode arm from position
“locked” (Fig.33/A) to position “open” (Fig.33/B) as shown in
the picture.
Locking the electrode arm
Fig.34: Locking the arm
2.
Push the electrode arm without much force into the locking
device until you feel and hear it engage (Fig.34).