3.4
Manual operation
3.4.1
Switching the device on
The device should always be switched on using the toggle switch on the front of the device. After powering it, the
display will first show the company logo, followed by a 3 seconds lasting language selection and later manufac
-
turer’s name and
address, device type, firmware version(s), serial number and article number.
In setup (see section
„3.4.3. Configuration via MENU“
),
in the second level menu “
General settings
” is an option
“
DC output after power ON
” in which the user can determine the condition of the DC output after power-up. Fac-
tory setting here is “
OFF
”, meaning that the device would start with the DC output being switched off. “
Restore
”
means that the last condition of the DC output will be restored, either on or off. The set values, however, are always
saved and restored.
After powering the device and during the start phase the AI signals undefined statuses on the
digital output pins such as ALARMS 1. Those must be ignored until it’s ready to work.
3.4.2
Switching the device off
On switch-off the last output condition and set values, as well as all settings are saved. Furthermore, a PF alarm
(power failure) will be signalled, but must be ignored here.
When acting the power button, the DC output will immediately switch off, but the device will keep running for a few
seconds longer until it completely stops.
3.4.3
Configuration via MENU
The MENU serves to configure all operating parameters which
are not constantly required. These can be set by finger touch on
the MENU touch area, but only if the DC output is switched OFF.
See figure to the right.
If the DC output is switched on the settings menu will not be shown,
only status information.
Menu navigation is by finger touch. Values are set using the rotary
knobs. The assignments of the rotary knobs, if multiple values can
be set in a particular menu, isn’t always depicted. Following rule for
such situations: upper value -> left knob, lower value .> right knob.
Some setting parameters are self-explanatory, others are not. The
latter will be explained on the pages following.