Page 46
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
PS 9000 T Series
►
How to adjust values with the rotary knobs
1.
First check if the value you want to change is already assigned to one of the
rotary knobs. The main screen displays the assignment with the two assigned
set values being inverted.
2.
If, as shown in the example, the assignment is voltage (U, left-hand knob)
and current (I, right-hand knob) and you wish to set the power the assignment
of the left-hand knob can be changed by tapping the green area for power.
This will switch the knob to power adjustment and highlight the power value.
3.
After successful selection, the desired value can be set within the defined limits. Selecting a digit is done by
pushing the rotary knob which shifts the cursor from right to left (selected digit will be underlined):
►
How to adjust values via direct input
1.
In the main screen, depending on the rotary knob assignment, values can
be set for voltage (U), current (I) or power (P) via direct input by tapping on
the small keypad symbol in the set/actual value display areas, e.g in the up-
permost area of voltage.
2.
Enter the required value using the ten-key pad. Similar to a pocket calcula-
tor the key
clears the input.
Decimal values are set by tapping the point key. For example, 54.3 V is set
with
and
.
3.
The display reverts to the main page and the set values take effect.