elektraLite MY575w Скачать руководство пользователя страница 3

 -                                     MY575 WASH 

Safety Instructions.

 

This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe 
operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in 
this user manual. 

MY575w 

is a high voltage fixture. Be careful when dealing with high voltages.     

Please read this manual. If you do not read this manual and damages occur to MY575w, then it could 
void the warranty.   

During shipping, 

MY575w

 may have been exposed to high temperature changes or humidity changes. So, as a 

precaution, do not switch 

MY575w

 on immediately. Condensation can damage 

MY575w 

so leave 

MY575w

 

switched off until it has reached room temperature. 
The electric connection must carry out by a qualified person and it is absolutely essential that 

MY575w

 be 

grounded

 
Always disconnect 

MY575w 

from the power source, when the device is not in use or before cleaning it. Only 

unplug 

MY575w

 from the power cord. Never pull out the plug out by pulling on the power cord. 

Take care, MY575w will heat up when it is turned on and it will be very hot to touch. 

 
Please keep 

MY575w 

away from children and the general public. Please be intelligent and use common sense 

when operating 

MY575w. 

 

General Guidelines.

 

MY575w

 is a lighting fixture for professional use on stages, in clubs, theatres, etc. 

MY575w 

should only be operated at 120 volts and only indoors. 

MY575w 

should not be operated 24/7 (24 hours a day; 7 days a week). 

MY575w 

needs operation breaks to 

ensure that it will work for a long time without problems. Please do not shake 

MY575w 

and avoid using brute 

force when installing or operating it.   
 
When choosing the location to install 

MY575w

, please make sure that it is not exposed to extreme heat, 

moisture or dust. The minimum distance between 

MY575w 

and the illuminated surface must be more than 3 

feet. 
 
Always mount 

MY575w 

with an appropriate safety cable. If you use the quick lock cam to hang 

MY575w

please make sure the 4 quick lock fasteners are 

locked into position correctly. 

   
Operate 

MY575w

 only when you are familiar with the features on the fixture. Do not permit operation by 

persons not qualified for operating it.   
All modifications to 

MY575w will invalidate the warranty. There are absolutely no exceptions.

 

 
If 

MY575w 

is operated in any way different to the one described in this manual, 

MY575w 

maybe damaged and 

the guarantee will be void.   

 

Содержание MY575w

Страница 1: ...MY 575w USER MANUAL V2 05 From Serial number ele632sp008...

Страница 2: ...ired 9 Speed of pan tilt movement adjustable 9 Advance Color mixing system Cyan Magenta Yellow The colors range goes extremely deep giving the Lighting Designer a large palette of colors 9 Additional...

Страница 3: ...hot to touch Please keep MY575w away from children and the general public Please be intelligent and use common sense when operating MY575w General Guidelines MY575w is a lighting fixture for professi...

Страница 4: ...A B C on the bottom of the housing holding the plate under which the lamp is located Carefully remove the metal plate 2 Carefully insert the lamp into the socket Please remember the lamp is polarized...

Страница 5: ...ing used Periodic safety inspections should be done of MY575w as the fixture does move If you do not have the qualifications and experience do not attempt the installation Improper installation can re...

Страница 6: ...ing the correct number on the display located on the base of MY575w You can set the same starting address for all fixtures or group of fixtures like all the MY575w s in your plot or you can make diffe...

Страница 7: ...wn buttons to change the address 2 The default for the lamp striking is from the board channel 14 The fixture s lamp will not just start up when you turn on the fixture The main menu is accessed by pr...

Страница 8: ...ONLI ON OFF Lamp on off via controller 1 LAMP DELA D 00 D 59 D 15 Delay lamp on RPAN ON OFF Pan Reverse VER V1 0 V9 9 Software Version LODA ON OFF Restore Default factory setting REST ON OFF Reset DE...

Страница 9: ...T DN to return to main menu Slave setting With this function you can define the device as slave 1 Select SLAV by pressing the UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select O...

Страница 10: ...el If you select D 14 the display will only show the DMX value of the 14th channel 4 Press ENTER to confirm 5 The display shows D XX X stands for the DMX value of the selected channel 6 Press ENTER or...

Страница 11: ...th this function you can switch the lamp on or off via an external controller 1 Select ONLI by pressing UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enabl...

Страница 12: ...0 3 Press UP to change the selection 4 Press ENTER to save and then EXIT DN to exit Switch 16 bit 8 bit With this function you can switch MY575 from 16 bit to 8 bit resolution 1 Select 16BI by pressin...

Страница 13: ...n adjust the lamp via the Display Panel The shutter opens and the lamp can be adjusted In this mode MY575 will not react to any control signal 1 Select LADJ by pressing UP button 2 Press ENTER the dis...

Страница 14: ...mber of hours 3 Press ENTER or EXIT DN to exit Clear fixture time With this function you can clear the running time of MY575 1 Select CLMT by pressing UP button 2 Press ENTER the display shows ON or O...

Страница 15: ...ect the channel no you would like to edit by pressing UP 6 Press ENTER to enter editing for the selected channel MY575w reacts to your settings The display shows the DMX value of the edited channel Su...

Страница 16: ...pressing UP 5 Press ENTER the display shows OFF 6 Press UP the display shows ON 7 Press ENTER the display shows SC02 You successfully downloaded the first scene 8 Adjust the Step time as described ab...

Страница 17: ...osition 32 63 DMX value CHANNEL 12 Speed channel for C Y M from maximum speed to minimum CHANNEL 13 Macros for C Y M color effects engine CHANNEL 14 Control channel for lamp ON lamp Off motor reset Al...

Страница 18: ...al 71 230 Beam shaper 231 255 Frost filter Channel 9 Zoom 0 255 Zoom 28 Zoom 7 Channel 10 Shutter strobe 0 31 Shutter closed 32 63 No function shutter open 64 95 Strobe effect slow to fast 96 127 No f...

Страница 19: ...12 224 231 Macro28 104 111 Macro13 232 239 Macro29 112 119 Macro14 240 247 Macro30 120 127 Macro15 248 255 Random CMY Channel 14 Lamp on off reset internal programs 0 19 color change normal by directi...

Страница 20: ...ot located in the default position after the reset 06Er Tilt head movement error This message will appear after the reset of the fixture if the head s magnetic indexing circuit malfunctions sensor fai...

Страница 21: ...causes premature failure of the lamp and other critical components There are no serviceable parts inside MY575w except for the lamp Please refer to the instructions under Installation instructions Sho...

Страница 22: ...MY575 WASH Other Elektralite Products include Also check out our website at www myelektralite com CP 3 Controller CP 10xt Controller CP 16 24 Controller...

Страница 23: ...MY575 WASH CP 20xt Controller TurboFog Fog Machine...

Страница 24: ...MY575 WASH Turbohazer Haze Machine...

Отзывы: