19
- MY575 WASH
ERROR MESSAGE
When you turn on
MY575w
, it will make a reset first. The display may show “XXer” while there are problems
with one or more channels. “XX” stands for channel 1,2,3,4,5,6,8,12,14,15 who has the testing sensor for
positioning .
For example, when the display shows “02Er”, it means there is some error in channel 2. If there are some
errors on channel 1, channel 2, channel 5 at the same time, you may see the error message “01Er”,
“02Er”,”05Er” flash repeated for 5 times, and then
MY575w
will generate a reset signal, all the stepper reset. If
the error message remains after performing reset more than 3 times, it will detect whether the fixture has more
than 3 errors. If the fixture has 3 errors or more, then all the channels will not work properly. However if the
fixture has less than 3 errors, only those channels which have errors will not work properly, other channels will
work as normal.
01Er:
(Color-wheel error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main PCB). The color wheel is not located in the default position after the reset.
05Er:
(Pan-yoke movement error) This message will appear after the reset of the fixture if the yoke’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or
its driving IC on the main PCB). The yoke is not located in the default position after the reset.
06Er:
(Tilt-head movement error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or
its driving IC on the main PCB). The head is not located in the default position after the reset.
08Er:
(effect-wheel error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The rotating gobo is not located in the default position after the reset.
09Er:
(Zoom error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The zoom is not located in the default position after the reset.
CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1) All screws, clamps etc. used to install
MY575w
have to be tight and must not be corroded. Check them
regularly because, remember,
MY575w moves
and so it will have an effect on whatever you are using to hang
the fixture.
2) There must not be any deformations on
MY575w’s
housing and internal parts. Also check the points where
MY575w
is installed including such things as ceiling mounting points, truss, half couplers, c clamps, safety
cables and so on).
4) Mechanical moving parts must not show any traces of wearing and must rotate evenly.
5) The power input cable must not show any damage or material fatigue.