 -                                     MY575 WASH 

 

 
 
 

ERROR MESSAGE 

 

When you turn on 

MY575w

, it will make a reset first. The display may show “XXer” while there are problems 

with one or more channels. “XX” stands for channel 1,2,3,4,5,6,8,12,14,15 who has the testing sensor for 
positioning . 
For example, when the display shows “02Er”, it means there is some error in channel 2. If there are some 
errors on channel 1, channel 2, channel 5 at the same time, you may see the error message “01Er”, 
“02Er”,”05Er” flash repeated for 5 times, and then 

MY575w 

will generate a reset signal, all the stepper reset. If 

the error message remains after performing reset more than 3 times, it will detect whether the fixture has more 
than 3 errors. If the fixture has 3 errors or more, then all the channels will not work properly. However if the 
fixture has less than 3 errors, only those channels which have errors will not work properly, other channels will 
work as normal.    

 
01Er: 

(Color-wheel error) This message will appear after the reset of the fixture if the magnetic-indexing circuit 
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the 
main PCB). The color wheel is not located in the default position after the reset. 

 
05Er: 

(Pan-yoke movement error) This message will appear after the reset of the fixture if the yoke’s 
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or 
its driving IC on the main PCB). The yoke is not located in the default position after the reset. 

 
06Er: 

(Tilt-head movement error) This message will appear after the reset of the fixture if the head’s 
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or 
its driving IC on the main PCB). The head is not located in the default position after the reset. 

 
08Er: 

(effect-wheel error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit 
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the 
main PCB). The rotating gobo is not located in the default position after the reset. 
 

09Er: 

(Zoom error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit 
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the 
main PCB). The zoom is not located in the default position after the reset. 
 

 

 

 

CLEANING AND MAINTENANCE 

The following points have to be considered during the inspection: 
1) All screws, clamps etc. used to install 

MY575w 

have to be tight and must not be corroded. Check them 

regularly because, remember, 

MY575w moves

 and so it will have an effect on whatever you are using to hang 

the fixture. 
2) There must not be any deformations on 

MY575w’s 

housing and internal parts. Also check the points where 

MY575w 

is installed including such things as ceiling mounting points, truss, half couplers, c clamps, safety 

cables and so on). 
4)  Mechanical moving parts must not show any traces of wearing and must rotate evenly.   
5)  The power input cable must not show any damage or material fatigue.   

Содержание MY575w

Страница 1: ...MY 575w USER MANUAL V2 05 From Serial number ele632sp008...

Страница 2: ...ired 9 Speed of pan tilt movement adjustable 9 Advance Color mixing system Cyan Magenta Yellow The colors range goes extremely deep giving the Lighting Designer a large palette of colors 9 Additional...

Страница 3: ...hot to touch Please keep MY575w away from children and the general public Please be intelligent and use common sense when operating MY575w General Guidelines MY575w is a lighting fixture for professi...

Страница 4: ...A B C on the bottom of the housing holding the plate under which the lamp is located Carefully remove the metal plate 2 Carefully insert the lamp into the socket Please remember the lamp is polarized...

Страница 5: ...ing used Periodic safety inspections should be done of MY575w as the fixture does move If you do not have the qualifications and experience do not attempt the installation Improper installation can re...

Страница 6: ...ing the correct number on the display located on the base of MY575w You can set the same starting address for all fixtures or group of fixtures like all the MY575w s in your plot or you can make diffe...

Страница 7: ...wn buttons to change the address 2 The default for the lamp striking is from the board channel 14 The fixture s lamp will not just start up when you turn on the fixture The main menu is accessed by pr...

Страница 8: ...ONLI ON OFF Lamp on off via controller 1 LAMP DELA D 00 D 59 D 15 Delay lamp on RPAN ON OFF Pan Reverse VER V1 0 V9 9 Software Version LODA ON OFF Restore Default factory setting REST ON OFF Reset DE...

Страница 9: ...T DN to return to main menu Slave setting With this function you can define the device as slave 1 Select SLAV by pressing the UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select O...

Страница 10: ...el If you select D 14 the display will only show the DMX value of the 14th channel 4 Press ENTER to confirm 5 The display shows D XX X stands for the DMX value of the selected channel 6 Press ENTER or...

Страница 11: ...th this function you can switch the lamp on or off via an external controller 1 Select ONLI by pressing UP button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enabl...

Страница 12: ...0 3 Press UP to change the selection 4 Press ENTER to save and then EXIT DN to exit Switch 16 bit 8 bit With this function you can switch MY575 from 16 bit to 8 bit resolution 1 Select 16BI by pressin...

Страница 13: ...n adjust the lamp via the Display Panel The shutter opens and the lamp can be adjusted In this mode MY575 will not react to any control signal 1 Select LADJ by pressing UP button 2 Press ENTER the dis...

Страница 14: ...mber of hours 3 Press ENTER or EXIT DN to exit Clear fixture time With this function you can clear the running time of MY575 1 Select CLMT by pressing UP button 2 Press ENTER the display shows ON or O...

Страница 15: ...ect the channel no you would like to edit by pressing UP 6 Press ENTER to enter editing for the selected channel MY575w reacts to your settings The display shows the DMX value of the edited channel Su...

Страница 16: ...pressing UP 5 Press ENTER the display shows OFF 6 Press UP the display shows ON 7 Press ENTER the display shows SC02 You successfully downloaded the first scene 8 Adjust the Step time as described ab...

Страница 17: ...osition 32 63 DMX value CHANNEL 12 Speed channel for C Y M from maximum speed to minimum CHANNEL 13 Macros for C Y M color effects engine CHANNEL 14 Control channel for lamp ON lamp Off motor reset Al...

Страница 18: ...al 71 230 Beam shaper 231 255 Frost filter Channel 9 Zoom 0 255 Zoom 28 Zoom 7 Channel 10 Shutter strobe 0 31 Shutter closed 32 63 No function shutter open 64 95 Strobe effect slow to fast 96 127 No f...

Страница 19: ...12 224 231 Macro28 104 111 Macro13 232 239 Macro29 112 119 Macro14 240 247 Macro30 120 127 Macro15 248 255 Random CMY Channel 14 Lamp on off reset internal programs 0 19 color change normal by directi...

Страница 20: ...ot located in the default position after the reset 06Er Tilt head movement error This message will appear after the reset of the fixture if the head s magnetic indexing circuit malfunctions sensor fai...

Страница 21: ...causes premature failure of the lamp and other critical components There are no serviceable parts inside MY575w except for the lamp Please refer to the instructions under Installation instructions Sho...

Страница 22: ...MY575 WASH Other Elektralite Products include Also check out our website at www myelektralite com CP 3 Controller CP 10xt Controller CP 16 24 Controller...

Страница 23: ...MY575 WASH CP 20xt Controller TurboFog Fog Machine...

Страница 24: ...MY575 WASH Turbohazer Haze Machine...

Отзывы: