background image

25

24

 

 If problems arise with the appliance, consult the following guide and try to resolve them 

by implementing the suggestions provided.
If the problems persist, contact Technical Assistance. Do not carry out repairs directly on the 
appliance       .

The company Elektra declines any and all responsibility for tampering or interventions carried 
out by non authorized persons. Such intervention automatically renders the guarantee null 
and void. The guide also contains problems that must be resolved directly by the Technical 

Assistance Service but which are explained to facilitate comprehension and repair 

operations.

TROUBLESHOOTING

BOILER WARNING: WATER LEVEL CONTROL ALARM, FAULT

If the following alert appears:
“ WATER LEVEL CONTROL SYSTEM FAULT -  MACHINE OFF - REPAIR ”
the fault could be due to:
1)  Water supply stoppage: restore it 
2)  Fault in the boiler water inlet solenoid valve or obstruction to the passing of water 
       through some parts of the machine
3)  Electrically insulating incrustations on the level probe or an interruption in its 
       electrical connection that prevents the presence of water in the boiler from being 
       detected:
 

       

Switch off the machine and contact Technical Assistance     

  

.

5

4

WATER COMES OUT OF THE STEAM WAND

This means that the boiler is completely full of water instead of containing a certain quantity
of steam.
The possible causes of this are:
-  Fault in the boiler water inlet solenoid valve.
-  Electrically insulating incrustation on the level probe or interruption in its electrical 
       connection.

       Switch off the machine, turn off the water supply and contact Technical Assistance       .

7

BREWING WATER TEMPERATURE CONTROL SYSTEM ALARM,  FAULT 

If the following alert appears:
“ BREWING WATER TEMPERATURE CONTROL SYSTEM FAULT -  MACHINE OFF - REPAIR ”
a major fault has occurred.

       Switch off the machine and contact Technical Assistance       .

ALARM: BUFFER BATTERY ABOUT  TO GO FLAT

The electronic control unit is equipped with a buffer battery that ensures the storing of the 
time and date.
The system continually controls the efficiency of the battery, warning in advance when it is 
about to go flat and advising its replacement.
When displaying the following alert:
“ BUFFER BATTERY ABOUT TO GO FLAT- REPLACE PROMPTLY ”

Contact Technical Assistance.

NOT SATISFACTORY BREWING ALARM

If, after dispensing selected with an automatic button, e.g. group 1 single short coffee, the 
following alert is displayed:
“ BREWING NOT SATISFACTORY- CHECK COFFEE TAMPING OR DOSING OR GRINDING ”
the coffee may not have been made according to Italian espresso standards, and therefore 
adjustments in tamping, dosing or grinding of the coffee powder are required. 
Perhaps even adjustments to temperature or brewing pressure are required (also consult 
chapters “C - ADJUSTMENTS”, paragraphs 1.5, 2).
Alternatively, there might be a fault due to:

 Water supply stoppage: restore it

 Fault or obstruction to the passing of water through some parts of the machine: 

        contact Technical Assistance.

THE MACHINE DOES NOT HEAT UP

Due to the (even temporary) lack of water in the boiler the heating element safety device 
may have been disactivated. 

      The heating element safety device can be manually reactivated, after the reason for the 
lack of water in the boiler has been eliminated or repaired       .

Contact Technical Assistance.

STEAM DOES NOT COME OUT OF THE WANDS WHEN THE MACHINE 

IS HOT

This problem normally arises after the machine has been switched on from cold and is 

due to the sticking of the vacuum break valve of the boiler; this does not negatively affect 

the use of the machine, in fact:

-   After venting all the air through a steam valve, wait until the machine heats up 

       normally and use it.

In the meantime, contact Technical Assistance.

6

1

2

3

Содержание KUP

Страница 1: ...INSTRUCTION MANUAL PROFESSIONAL ESPRESSO COFFEE MACHINES KUP GB...

Страница 2: ...NOT HEAT UP STEAM DOES NOT COME OUT OF THE WAND WHEN THE MACHINE IS HOT WATER COMES OUT OF THE STEAM WAND WATER DOES NOT COME OUT OF THE DISPENSING GROUP WHEN THE MANUAL BUTTON IS USED ONE DISPENSING...

Страница 3: ...IC PROGRAMMING 1 1 LANGUAGE SELECTION 1 2 TIME AND DATE SETTING 1 3 NIGHT CYCLE PROGRAMMING 1 4 BREWING TEMPERATURE SETTING 1 5 BREWING CRONO ENABLING 1 6 SCHEDULED MAINTAINANCE ALERTS RESET 1 7 COFFE...

Страница 4: ...ns are intended for barman espresso coffee machine operator and installation maintenance technician OPERATION INSTRUCTIONS These instructions are intended for barman espresso coffee machine operator T...

Страница 5: ...as unsuitable and therefore dangerous The manufacturer cannot be held liable for any damage or injury caused by improper wrong or unreasonable use This manual is an essential and integral part of the...

Страница 6: ...ent in it Children should not play with the equipment The cleaning and maintenance intended to be performed by the user should not be performed by children without super vision Disconnect the applianc...

Страница 7: ...INTERFACE The machine has an alphanumeric display which allows communications between the user and the same machine in a specific selected language The inputs to the machine are executed by means of...

Страница 8: ...ATTERY ABOUT TO GO FLAT REPLACE PROMPTLY the following major alarms BOILER WATER LEVEL CONTROL SYSTEM FAULT MACHINE OFF REPAIR BREWING WATER TEMPERATURE CONTROL SYSTEM FAULT MACHINE OFF REPAIR SOUND E...

Страница 9: ...the following Directives 2001 95 EC General safety 2004 1935 EC Materials and objects in contact with food MOCA 2006 42 EC Machinery 2011 65 EC Restrictions on use of some dangerous material ROHS 201...

Страница 10: ...ics to quit the programming options scroll the menu by the button until the following signal is displayed TO QUIT PRESS ENTER TO REPEAT PRESS then press the ENTER button the machine automatically resu...

Страница 11: ...g the same button when the desired dose has been dispensed This function is enabled at all times irrespective of the machine status even in the case of a major fault so as to enable washing or checks...

Страница 12: ...peration suitable for programming 2 The main menu appear on the display press any of the coffee buttons marked with the sign to scroll the menu and reach the desired topic i e GROUP 1 CLEANING or GROU...

Страница 13: ...EPAIR a major fault has occurred Switch off the machine and contact Technical Assistance ALARM BUFFER BATTERY ABOUT TO GO FLAT The electronic control unit is equipped with a buffer battery that ensure...

Страница 14: ...ned causes are not responsible for the fault this means that there is a blockage in the drain pipes external to the machine contact a plumber Also consult chapter B INSTALLATION paragraph 3 9 11 DISPO...

Страница 15: ...ste reduced but a more rational use of non renewable resources is also ensured 1 Cut the strap that keeps the box closed 2 Open the top of the box and remove the shock proof panels inside remove the a...

Страница 16: ...clockwise to shorten it There are no screws or nuts to be loosened or tightened WATER CONNECTION The water is fed thanks to a connection with the drinkable water supply at a minimum pressure of 0 15 M...

Страница 17: ...ey in the lock on the control panel gently press and turn it clockwise the machine automatically enters a state of partial operation suitable for programming 2 The instructions for the using the main...

Страница 18: ...be zero set by entering the Reset Code known to the technician 1 1 1 2 1 3 1 4 BREWING PRESSURE ADJUSTING With a view to obtaining the best quality in the cup brewing pressure may be adjusted Recomme...

Страница 19: ...COD 05761035 Edition 22 02 2018 Tipografia Crivellari 1918 ELEKTRA SRL VIA A VOLTA 18 31030 DOSSON DI CASIER TREVISO ITALY TEL 39 0422 490405 R A FAX 39 0422 490620 E mail info elektrasrl com Website...