background image

16

MICROPROCESSOR TEMPERATURE 

CONTROLLER

FOR CENTRAL HEATING BOILERS 

AND HOT SERVICE WATER BOILERS

Содержание Logic SP-16

Страница 1: ...16 MICROPROCESSOR TEMPERATURE CONTROLLER FOR CENTRAL HEATING BOILERS AND HOT SERVICE WATER BOILERS ...

Страница 2: ...with marked functions 1 Turning on hold ENTER button for 2 sec 2 LCD display 3 Indicator lights 4 Device control buttons 5 Blower start up indicator 6 Central heating pump start up indicator 7 Hot service water pump start up indicator 8 3 15 A fuse SP 16 Manual ...

Страница 3: ...yed on LCD Central heating CH temperatures current and set up Hot service water HSW temperatures current and set From the main page you have the access to several functions pressing enters into central heating temperature adjusting mode you set up desired temperature with and When temperature decreases below o 35 C and ENTER button is pressed central heating pump turns off Controller enters SUMMER...

Страница 4: ...n delaying HSW pump start up by set up number of degrees i e o o hystheresis 2 set up temperature 50 C pump shall start up when service water temperature o decreases to 48 C This function works in HSW priority and summer mode 4 PUMP START TEMP PUMP START TEMP 0 35 c FUNCTIONS MANUAL OPERATION function is to fire up the boiler it enables independent start up of controller and blower outputs Pressin...

Страница 5: ...mber that all personal settings will be lost END OF WORK turns the controller off To turn It on again press and hold ENTER button Controller has got hidden installation menu to get there press and hold and buttons for 3 seconds Changes of parameters in that menu should be made by qualified person Your changes of those parameters may cause controller misoperation INSTALLATION MENU TURN OFF TIME fun...

Страница 6: ... humidity 95 7 I insulation class 8 3 15 A fuse 9 Controller has got function preventing from premature freezing of o installation in case of temperature decrease below 6 C circulation pump starts up automatically 10 Controller is equipped with secondary protection emergency thermostat which protects the boiler against overheating 5 Use 1 Connect feeder of CH and HSW pump a yellow green conductor ...

Страница 7: ...alled and operated in accordance with rules of operating electrical devices Controller must not be exposed to water or to conditions causing steam condensation i e rapid changes of ambient temperature 5 In cases of controller misoperation first check a the fuse b connections stability and technical condition of cooperating devices that means the blower pumps c Set the controller to manufacturer se...

Страница 8: ...ice centre 7 Seller is obliged to fill in the warranty card on the day of giving out the equipment Warranty card which is not filled in or having any corrections or cross outs precludes exercising warranty rights Information on utilization of electric and electronic devices This symbol placed on products or documentation attached to them informs that unserviceable electric or electronic devices mu...

Страница 9: ...9 Notatki ...

Страница 10: ...10 Notatki ...

Страница 11: ...11 Data sprzeda y Podpis Piecz tka punktu sprzeda y Data Zakres reklamacji Podpis i pieczatka Warranty card ...

Страница 12: ...ul Moczyd o 10a 30 698 Kraków tel 012 650 47 90 fax 012 650 47 91 e mail biuro electronics net pl Producent Zak ad Elektroniczny Electronics Tadeusz Wilgocki ...

Отзывы: