DOC. NO. 5956.573.05
P. 43 / 88
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
WTM180/ RTM180
PROG 003
1.
GENERIC FUNC.
Enter GENERIC FUNC. and set the following parameters.
Set default par.
Yes / 1
Sets all parameters to their default value.
2.
Switch the machine off and then on again.
3.
GENERIC FUNC.
Enter GENERIC FUNC. and set the following parameters.
Appl. type
Pw Ws Ri / 1
Type of machine: Without Dt
Pw Ws Ri Dt / 2
Type of machine: With Dt
Appl. direct.
Left / 0
Rack feed direction: Left
Right / 1
Rack feed direction: Right
Speed nr. 1
35
Indicates feed gear motor operation frequency at speed 1 [Hz].
Wash time sp 1
108
Time from when the last rack releases the auto start lever until the wash
pumps stop when speed 1 [s] is set.
Speed nr. 2
58
Indicates feed gear motor operation frequency at speed 2 [Hz].
Wash time sp 2
59
Time from when the last rack releases the auto start lever until the wash
pumps stop when speed 2 [s] is set.
Drain enable
63
Enable draining and cleaning cycles.
Heat two comm.
No / 0
Wash tank heating element management.
Heating manage
High / 0
Machine heating power management.
Boiler load tank
No / 0
The tank is filled by means of a dedicated solenoid valve.
Fahrenheit vis.
Unit of measure used in displaying the temperatures; if set to “Yes” the
temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
No / 0
Celsius visualization
Yes / 1
Fahrenheit visualization
Rinse autostart
Indicates the type of rinse stage control.
Software / 0
Up to serial number 71800000
Mechanical / 1
From serial number 71800001
Max motor curr.
see par. A4.8
Indicates the max. current deliverable to the gear motor by the inverter.
Nsf settings
No / 0
Duo and tank temperature standard setting.
4.
RINSE MODULE
Enter RINSE MODULE and set the following parameters.
Boil. temp. start
92
Boiler temperature set point at start of rinse stage.
Boiler temper.
86
Boiler temperature set point.
Boiler temper warmup
86
Boiler warm-up temperature.
Delta T stand-by
5
Boiler temperature decrease during standby.
First boil. temp.
59
First USA compact boiler temperature set point.
Duo temper.
70
Tank temperature set point.
Hist. duo temp.
5
Tank hysteresis temperature.
Drain del. airgap
32
Time from reaching level 0 (level in air trap) in the air gap, to stopping of
the rinse pump.
Duo heat. unrel.
No / 0
Enables activation of the DUO heating element even if the tank and
boiler heating elements are on.
5.
WASH MODULE
Enter PREWASH MODULE and set the following parameters.
Wash module
1165 / 0
Type of wash module.
Tank temper.
66
Tank temperature set point.
Histeresys temp.
2
Tank hysteresis temperature.
Condensing unit
No / 0
Without CU
Yes / 1
With CU
Wash temp. ready
64
Wash tank “warmup end” temperature.
6.
PREWASH MODULE
Enter DT MODULE and set the following parameters.
Prewash module
1165-600 / 0
Type of prewash module.
Standby level
220
Indicates the max. level in prewash tank.
Run level
180
Indicates the max. prewash tank level when the prewash pumps are
working.
7.
DT MODULE
Enter WASH MODULE and set the following parameters.
DT temper
70
Drying tunnel temperature set point.
DT type
Standard / 0
Indicates the type of DT installed.
8.
Switch the machine off and then on again.