78
12:8 CONDENSE WATER CONTAINER IS FULL
The pump will run when a program starts for normally 15 seconds. Then it will run again after
normally 3 minutes. The pump will also run if the input for the float is trigged.
The error code is activated if the pump has tried to empty the condense water container without the
signal from the float in the condense water container has been deactivated.
When the float in the condense water container is restored it is possible to reset the error code from
the timer. The error code is reset from the timer by a short press on the control knob/start button.
A long press on the control knob/start button will make the timer reset and ongoing program will
be ended.
The error code can be trigged if:
• The condense water container is full and the pump is not operating. Check the pump by
activating the
CONDENSER PUMP
menu in the
ACTIVATE OUTPUTS
menu when the machine
is in service mode.
• If the pump is running and no water is coming out, the drain is blocked or the float is out of order.
• If water coming out of the hose, it might be partly blocked.
If the pump does not run or if there is no level in the condense water container check the harness,
connectors and functions by reading the electrical schematic and by using the
SHOW INPUTS
menu when the machine is in service mode.
12:11 DRYING ERROR WITH RMC PROGRAM
The error code is activated if the RMC system does not register that the clothes are dry within the
maximum drying time. When the error is trigged the machine will automatically go to the cooling
module before the program ends.
The error code is reset from the timer by a short press on the control knob/start button. A long press
on the control knob/start button will make the timer reset and ongoing program will be ended.
If the clothes are still wet after maximum drying time and the dryer is not overloaded, check that the
heating system is working correct by using the
ACTIVATE OUTPUTS
menu when the machine is
in service mode.
Note!
Make sure that the fan is active before turning on the heat.
If the clothes are dry, check the RMC system and harness, connectors and functions by reading the
electrical schematic and by using the
SHOW INPUTS
menu when the machine is in service mode.
• RMC value no load = 0%
• RMC value 100K Ohm between lifter and drum = ~24%
• RMC value system short circuit = 50%