12:5 OUTLET AIR SENSOR - OPEN
The error code is activated if the outlet air sensor or its wires is open.
If the outlet air temperature in the
SHOW INPUTS
menu show a temperature of -10 °C the outlet air
sensor is open.
When the outlet air sensor is restored the error code is automatically reset and the ongoing program
will continue. A long press on the control knob/start button will make the timer reset and ongoing
program will be ended.
The error code can be trigged if:
• The sensor, harness or connector is broken.
The sensor shall measure around 5 K Ohm in room temperature, see table. (Measure direct over
the sensor).
If the measure of outlet air is OK, but there is still an error code:
• Check the harness, connectors and functions by reading the electrical schematic and by using
the
SHOW INPUTS
menu when the machine is in service mode.
If the input for the outlet air sensor is short circuited the timer will display the inlet air temperature
of 100 °C.
Outlet air sensor resistor value
Temperature
26.7 K Ohm
– 10 °C
6–3.9 K Ohm
20–30 °C
330 Ohm
100 °C
12:6 OUTLET AIR SENSOR - SHORT-CIRCUITED
The error code is activated if the outlet air sensor or its wires is short circuited.
If the outlet air temperature in the
SHOW INPUTS
menu show a temperature of 100 °C the outlet air
sensor is open.
When the outlet air sensor is restored the error code is automatically reset and the ongoing program
will continue. A long press on the control knob/start button will make the timer reset and ongoing
program will be ended.
The error code can be trigged if:
• The sensor, harness or connector is broken.
The sensor shall measure around 5 K Ohm in room temperature, see table. (Measure direct over
the sensor).
If the measure of outlet air sensor is OK, but there is still an error code:
• Check the harness, connectors and functions by reading the electrical schematic and by using
the
SHOW INPUTS
menu when the machine is in service mode.
If the input for the outlet air sensor is open circuited the timer will display the inlet air temperature of
0 °C.
Outlet air sensor resistor value
Temperature
26.7 K Ohm
– 10 °C
6–3.9 K Ohm
20–30 °C
330 Ohm
100 °C