SYSTEM CHECKS

The System Checks menu provides the ability to 
monitor overall system performance. Specifi c elements 
monitored include the dirt receptacle level, airfl ow 
performance, motor and electrical systems, and the need 
for power unit service.  The happy face indicates that 
each monitored element of the power unit is performing 
at optimal levels.  Use the right and left toggle buttons 
to scroll through the SYSTEM CHECK screens to view 
each system monitoring element.

Main Screen

Dirt Receptacle and Happy Face

This display denotes that the dirt receptacle does NOT 
currently need to be emptied.

Three to Five Performance Bars and Happy Face

This display indicates the system is performing at the 
optimal airfl ow level.  The power unit motor is operating 
at optimum performance when all fi ve power bars are 
illuminated.  Normal operating performance is when 
three to fi ve bars are shown.  Performance levels 
will decrease as the fi lter is loaded with debris or as 
the motor has signifi cant wear.  Fewer bars will be 
illuminated as performance decreases.  

When the power unit is off, the display will illuminate the 
airfl ow level of the last operating cycle.  Note: It is also 
normal to see changes in performance when specialty 
attachments are used.  

Motor Icon and Happy Face

This display indicates all electrical and motor 
components are functioning properly.

Telephone Icon and Happy Face

This screen indicates that the system has NOT 
encountered any error conditions and it is NOT 
necessary to call for service at this time.

System Run Time

This display shows you the overall number of hours that 
the power unit has operated.  It shows your total time of 
vacuuming with the Beam system.

Содержание SC385 LCD

Страница 1: ...mats can be customized using the USER SETUP menu To enter the USER SETUP menu press the Enter button Temperature Customization Use the Left and Right toggle buttons to select the temperature format of either C or F Once the correct format has been selected press the Enter button to proceed to the next screen Time Format Customization Use the Left and Right toggle arrows to select the temperature f...

Страница 2: ...otor is operating at optimum performance when all five power bars are illuminated Normal operating performance is when three to five bars are shown Performance levels will decrease as the filter is loaded with debris or as the motor has significant wear Fewer bars will be illuminated as performance decreases When the power unit is off the display will illuminate the airflow level of the last opera...

Страница 3: ... press the Enter button to return to the Main Screen This will reset the timer for the bucket monitor Empty Flashing Power Bars with Sad Face This screen is displayed when the power unit motor is unable to operate at optimal system performance When only 2 bars or less are illuminated the airflow is restricted meaning the vacuums cleaning power has decreased If the remaining bars are flashing the a...

Страница 4: ...or service This indicates a motor failure where service is needed Phone Icon with Sad Face This screen will be displayed for either of two reasons 1 The system experiences a failure that requires repairs by an authorized Beam service technician 2 The power unit reaches 500 hours in the life cycle when the motor brushes and filter should be checked for wear To resolve this system alert contact a Be...

Отзывы: