Beam Central Vacuum Systems

PLATINUM LCD

INSTRUCTION MANUAL

Read This Manual Thoroughly Before Use

MAIN SCREEN

The main screen is shown when the system is 
connected to an electrical outlet. This is the
screen displayed in regular operations mode with full system 
performance. The system performance plus local time and 
temperature can be viewed from the Main Screen.  

Along the bottom of the screen the following icons are 
displayed from left to right, the Power(

) icon, the Left(

) and 

Right(

) Toggle Arrow icons and the Enter (

) icon.  To 

scroll through the LCD menus, the button directly below each 
corresponding icon executes the navigational feature.

USER SETUP

Your LCD enabled power unit provides the ability to customize 
the temperature,(Celcius or Fahrenheit) and time formats,(12-
hour or 24-hour).  Formats can be customized using the 
USER SETUP menu.  To enter the USER SETUP menu, press 
the <Enter> button. 

Temperature Customization

Use the Left and Right toggle buttons to select the 
temperature format of either C or F.  Once the correct format 
has been selected, press the <Enter> button to proceed to the 
next screen.

Time Format Customization

Use the Left and Right toggle arrows to select the temperature 
format of either 12 or 24 hours.  Once the correct format has 
been selected, press the <Enter> button to proceed to the next 
screen.

Time Setting

The time can be changed by using the Left and Right toggle 
buttons.  The fi rst number fi eld in the display is underlined with 
a bar, indicating that it can be adjusted with the toggle buttons.  
Press the <Enter> button to proceed to the next number fi eld.

Review User Setup Settings

The next screen displays the temperature and time with the 
user selected formats.  Press the <Enter> button to return to 
the Main Screen

 

Power Button

Toggle Buttons

Enter Button

Содержание SC385 LCD

Страница 1: ...mats can be customized using the USER SETUP menu To enter the USER SETUP menu press the Enter button Temperature Customization Use the Left and Right toggle buttons to select the temperature format of either C or F Once the correct format has been selected press the Enter button to proceed to the next screen Time Format Customization Use the Left and Right toggle arrows to select the temperature f...

Страница 2: ...otor is operating at optimum performance when all five power bars are illuminated Normal operating performance is when three to five bars are shown Performance levels will decrease as the filter is loaded with debris or as the motor has significant wear Fewer bars will be illuminated as performance decreases When the power unit is off the display will illuminate the airflow level of the last opera...

Страница 3: ... press the Enter button to return to the Main Screen This will reset the timer for the bucket monitor Empty Flashing Power Bars with Sad Face This screen is displayed when the power unit motor is unable to operate at optimal system performance When only 2 bars or less are illuminated the airflow is restricted meaning the vacuums cleaning power has decreased If the remaining bars are flashing the a...

Страница 4: ...or service This indicates a motor failure where service is needed Phone Icon with Sad Face This screen will be displayed for either of two reasons 1 The system experiences a failure that requires repairs by an authorized Beam service technician 2 The power unit reaches 500 hours in the life cycle when the motor brushes and filter should be checked for wear To resolve this system alert contact a Be...