25
Element does not cycle:
If the element does not cycle when the switch is set in a
position other than high the switch is defective.
Indicator light does not glow:
If indicator light does not glow when the switch is turned
on, remove the back panel of the backguard, turn the
switch on, and measure the voltage drop between termi-
nals H1 and neutral. If the meter reads zero the switch
is defective. If the meter reads line to neutral voltage
(around 120 VAC) the light or the wiring to the light is
defective.
Indicator light glows full brilliance with the warm
and serve switch turned off:
If indicator light glows full brilliance with the warm and
serve switch off, the switch is defective.
Содержание NEXT GEN
Страница 30: ...30 SAMPLE SCHEMATIC FOR ES100 CONTROL SYSTEM ...
Страница 37: ...37 SAMPLE SCHEMATIC FOR THE ES 200 CONTROL SYSTEM ...
Страница 46: ...46 SAMPLE SCHEMATIC FOR THE ES 300 CONTROL SYSTEM ...
Страница 56: ...56 SAMPLE SCHEMATIC FOR THE ES 400 CONTROL SYSTEM ...
Страница 66: ...66 SAMPLE SCHEMATIC FOR THE ES 450 CONTROL SYSTEM ...
Страница 87: ...87 NOTES ...
Страница 88: ...88 ...