![Electrolux EWM2000 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/electrolux/ewm2000/ewm2000_service-manual_100459009.webp)
Table 2
:
FULL SMD version with on/off switch on the programme selector
(the programme selector can be on the right or on the left of the module)
SSD-P APdV, EB, HD 01/05
2.1
599 34 71-47
ACCE
SS TO TH
E
DIAGNOSTIC
S
To access the diagnostics system:
→
switch off the appliance
→
press the START/PAUSE button (8) together with one of the
other buttons and then, holding down both buttons, switch on
the appliance by turning the programme selector one position
clockwise.
→
hold both buttons down until the buzzer (if featured) sounds and
the LEDs begin to flash (about 4 seconds).
DIAGNOSTIC CYCL
E
→
Correct operation of all the components in the appliance can be
checked by turning the programme selector knob clockwise.
2. Operation of the user interface
(step 0, page 6.1)
3. Water fill to wash compartment
(step 1, page 6.1)
4. Water fill to pre-wash compartment
(step 2, page 6.1)
5. Water fill to conditioner compartment
(step 3, page 6.1)
6. Hot water fill or fill to bleach compartment (certain models only)
(step 4, page 6.1)
7. Heating and, in Jetsystem models, recirculation
(step 5, page
6.1)
8. Check for leaks from tub
(step 6, page 6.1)
9. Drain and spin, check for pressure switch congruency
(step 7,
page 6.1)
10. Drying (washer/dryers only)
(step 8, page 6.1)
ALARMS
To read the last alarm condition, after accessing the diagnostics
system:
→
turn the programme selector knob to the last position but one
(23
or
11
).
To cancel the last memorised alarm condition:
→
press START/PAUSE button (
8
) and no.
4
button at the same
time during one of the 8 phases of the diagnostic cycle and not
in the alarm or configuration reading positions.
→
The alarm is cancelled also when a new configuration is given to
the main PCB.
CONFIGURATION OF THE
MAI
N
PC
B
To access the machine configuration procedure, first enter the
diagnostics system, and then:
→
turn the programme selector
clockwise
to the last position (
24
or 12
); the code relative to the programme selector is displayed
and after 2 seconds the code relative to the first of the 16 digits
of the configuration code (position 0) is displayed
→
when one of the option buttons is pressed (with the exception of
the START/PAUSE button), all the digits, which make up the
configuration code, are displayed in sequence.
→
press the START/PAUSE button (8) to modify the configuration
code (digit by digit).
→
when all 16 digits have been entered, check that the code is
correct, then memorize the code by pressing the
START/PAUSE button and one of the option buttons at the
same time; these buttons should be held down for at least 4
seconds (i.e. the buzzer sounds).
EXIT
ING
→
To exit the diagnostic cycle, switch the appliance off, on, and
then off again.
Содержание EWM2000
Страница 2: ...SSD P APdV EB HD 01 05 II 599 34 71 47 ...
Страница 6: ...SSD P APdV EB HD 01 05 VI 599 34 71 47 ...
Страница 56: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 1 599 34 71 47 AC MOTOR ...
Страница 57: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 2 599 34 71 47 DC MOTOR ...
Страница 64: ...PICTURES LINKED TO FAULT FINDING SSD P APdV EB HD 01 05 14 1 599 34 71 47 pic 01 pic 02 pic 03 pic 04 ...
Страница 65: ...SSD P APdV EB HD 01 05 14 2 599 34 71 47 pic 05 pic 06 pic 07 PICTURES LINKED TO FAULT FINDING ...
Страница 66: ...SSD P APdV EB HD 01 05 14 3 599 34 71 47 pic 08 pic 08a pic 08b pic 09 pic 10 PICTURES LINKED TO FAULT FINDING ...
Страница 67: ...SSD P APdV EB HD 01 05 14 4 599 34 71 47 pic 11 pic 12 pic 13 pic 14 PICTURES LINKED TO FAULT FINDING ...
Страница 68: ...SSD P APdV EB HD 01 05 14 5 599 34 71 47 pic 15 pic 16 pic 17 pic 18 PICTURES LINKED TO FAULT FINDING ...
Страница 69: ...SSD P APdV EB HD 01 05 14 6 599 34 71 47 pic 19 pic 20 pic 21 pic 22 PICTURES LINKED TO FAULT FINDING ...
Страница 70: ...SSD P APdV EB HD 01 05 14 7 599 34 71 47 pic 23 pic 24 pic 25 pic 26 PICTURES LINKED TO FAULT FINDING ...
Страница 71: ...SSD P APdV EB HD 01 05 14 8 599 34 71 47 pic 27 pic 28 pic 29 pic 30 PICTURES LINKED TO FAULT FINDING ...
Страница 72: ...SSD P APdV EB HD 01 05 14 9 599 34 71 47 pic 31 pic 32 pic 33 PICTURES LINKED TO FAULT FINDING ...
Страница 73: ...SSD P APdV EB HD 01 05 14 10 599 34 71 47 pic 34 pic 35 PICTURES LINKED TO FAULT FINDING ...
Страница 74: ...NOTES SSD P APdV EB HD 01 05 14 11 599 34 71 47 ...