![Electrolux EWM2000 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/electrolux/ewm2000/ewm2000_service-manual_100459047.webp)
ALARM CODES
SSD-P APdV, EB, HD 01/05
8.29
599 34 71-47
YES
NO
NO
NO
NO
YES
YES
Washing NTC sensor failure.
(ohm value of the NTC out of limits)
Checks to do:
E71
Get inside diagnostic cycle and fill
in water on
step 5
to make the
pressure switch operating .Turn off
machine and on main board plug
measure between J4-1 and J4-2
an Ohm value (between 5.7 and
6.3 KOhm at 20
°
C)
Do you read the Ohm value?
-
see pic .16
-
Unplug connectors.
Measure directly on
the NTC the Ohm
value. Do you read
the right Ohm value?
-
see pic. 27
-
Change the NTC
sensor and run again
the diagnostic cycle
to verify any further
possible alarm.
Measure between J4-1 and body
of the machine and between J4-2
and body of the machine. Do you
measure any dispersion?
-
see pic. 20 -
Change/Check the
cable and run again
the diagnostic cycle
to verify any further
possible alarm.
Unplug connector and measure
directly between NTC sensor
body of the machine . Do you
measure any dispersion? The
machine must have water inside.
-
see pic.31
-
Change the NTC sensor and run
again the diagnostic cycle to verify
any further possible alarm.
Change the Main
board and run again
the diagnostic cycle
to verify any further
possible alarm.
Change/Check the
cable and run again
the diagnostic cycle
to verify any further
possible alarm.
YES
If there are burn marks on
electronic board, see page 13.1-2
Содержание EWM2000
Страница 2: ...SSD P APdV EB HD 01 05 II 599 34 71 47 ...
Страница 6: ...SSD P APdV EB HD 01 05 VI 599 34 71 47 ...
Страница 56: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 1 599 34 71 47 AC MOTOR ...
Страница 57: ...BASIC CIRCUIT DIAGRAM SSD P APdV EB HD 01 05 11 2 599 34 71 47 DC MOTOR ...
Страница 64: ...PICTURES LINKED TO FAULT FINDING SSD P APdV EB HD 01 05 14 1 599 34 71 47 pic 01 pic 02 pic 03 pic 04 ...
Страница 65: ...SSD P APdV EB HD 01 05 14 2 599 34 71 47 pic 05 pic 06 pic 07 PICTURES LINKED TO FAULT FINDING ...
Страница 66: ...SSD P APdV EB HD 01 05 14 3 599 34 71 47 pic 08 pic 08a pic 08b pic 09 pic 10 PICTURES LINKED TO FAULT FINDING ...
Страница 67: ...SSD P APdV EB HD 01 05 14 4 599 34 71 47 pic 11 pic 12 pic 13 pic 14 PICTURES LINKED TO FAULT FINDING ...
Страница 68: ...SSD P APdV EB HD 01 05 14 5 599 34 71 47 pic 15 pic 16 pic 17 pic 18 PICTURES LINKED TO FAULT FINDING ...
Страница 69: ...SSD P APdV EB HD 01 05 14 6 599 34 71 47 pic 19 pic 20 pic 21 pic 22 PICTURES LINKED TO FAULT FINDING ...
Страница 70: ...SSD P APdV EB HD 01 05 14 7 599 34 71 47 pic 23 pic 24 pic 25 pic 26 PICTURES LINKED TO FAULT FINDING ...
Страница 71: ...SSD P APdV EB HD 01 05 14 8 599 34 71 47 pic 27 pic 28 pic 29 pic 30 PICTURES LINKED TO FAULT FINDING ...
Страница 72: ...SSD P APdV EB HD 01 05 14 9 599 34 71 47 pic 31 pic 32 pic 33 PICTURES LINKED TO FAULT FINDING ...
Страница 73: ...SSD P APdV EB HD 01 05 14 10 599 34 71 47 pic 34 pic 35 PICTURES LINKED TO FAULT FINDING ...
Страница 74: ...NOTES SSD P APdV EB HD 01 05 14 11 599 34 71 47 ...