VERIFICATION OF ALARM CODES
In order to facilitate identification of an ALARM CONDITION indicated on the control panel and which
causes one of the safety features to intervene, the possible causes for each alarm condition are listed in
the table below together with suggested solutions.
Note
: The control board is unlikely to be the cause of an alarm condition, and should therefore be
checked last.
ALARMS
SAFETY DEVICE
POSSIBLE CAUSES
[A L 1]
"NTC" SENSOR
SHORT-CIRCUITED
Range < 450
Ω
a) Temperature sensor faulty (short-circuited)
b) Wiring short-circuited
c) Temperature too high (>90°C)
[A L 2]
"NTC" SENSOR
OPEN-CIRCUITED
Range > 26,700
Ω
a) Temperature sensor faulty (open)
b) Wiring open circuit/disconnected
c) Temperature too low (< -10°C)
[A L 3]
WATER HEATING
TIME-OUT
Water does not reach correct
temperature within 45 minutes after
the heating element switches
On
a) Heating element open circuit
b) Safety thermostat open
c) Wiring open circuit/loose
d) NTC sensor incorrectly positioned/Poor
thermal contact
e) Insufficient water circulation
f) Motor faulty (pumps/washing impeller)
g) Central filter clogged
[A L 4]
*INTERVENTION OF
ANTI-FLOODING
DEVICE
a) Water leakage from various couplings
b) Water leakage from motor (sealing ring, shaft
capsule etc.)
c) Floating sensor jammed
d) Float micro-switch faulty
[A L 5]
WATER FILL TIME-OUT
Correct level not reached.
The pressure switch does not switch
to "FULL" (1-3) within 4 minutes
after the solenoid is energised
*PRESSURE SWITCH ON
"EMPTY" (1-2)
After correct level is reached, the
pressure switch returns to
"EMPTY" (1-2) and does not return
to "FULL" (1-3) within 90 seconds
a) Tap closed
b) Fill hose kinked/intervention of Aqua-stop
device
c) Water mains pressure <30 kPa (4 PSI)
d) Intervention of ANTI-OVERFLOW device
e) Fill solenoid/connections opeb circuit
f) Pressure switch faulty/false contacts
g) Obstruction or leakage in IWMS-pressure
switch tube
h) Central filter clogged
i) Excessive foam
j) Dishes upside down
k) Siphon created in drain hose
[A L 6]
WATER DRAIN
TIME-OUT
a) Domestic drain outlet unsuitable (obstructed)
b) Motor faulty (pumps/drain impeller)
c) Pressure switch faulty (jammed on 1-3)
d) IWMS - Pressure switch tube obstructed
e) IWMS – sump breather tube obstructed
f) Control board (Relay faulty)
[A L 7]
MOTOR INOPERATIVE
a) Motor winding short-circuited
b) Capacitor open/short-circuited
c) Electrical connections broken/detached
d) Motor jammed by foreign bodies
e) Tachimetric sensor open/short-circuited
[A L 8]
MOTOR TRIAC
SHORT-CIRCUITED
a) Control board (Triac short-circuited)
When in an alarm condition, the dishwasher remains inoperative, and does not perform any
function.
To reset the alarm condition, press
Sw0
to switch off the appliance.
When the appliance is switched on again:-
After alarm conditions marked with an asterisk (*), the cycle is CANCELLED, and will
restart from the beginning.
After other alarm conditions, the cycle is SUSPENDED, and will resume from the point of
interruption.
Содержание ESI6180U
Страница 2: ...Page 2 DW 107 MODELS ESI6180X EX VIEW DRAWING 3927 ESI6180U OUTER PANEL LINER ASSEMBLY ...
Страница 4: ...Page 4 DW 107 MODELS ESI6180X EX VIEW DRAWING 3926 ESI6180U ELECTRICAL ASSEMBLY ...
Страница 6: ...Page 6 DW 107 MODELS ESI6180X EX VIEW DRAWING 3890 ESI6180U WATER CIRCUIT ASSEMBLY ...
Страница 8: ...Page 8 DW 107 MODELS ESI6180X EX VIEW DRAWING 3924 ESI6180U WATER SOFTENER ASSEMBLY ...
Страница 10: ...Page 10 DW 107 MODELS ESI6180X EX VIEW DRAWING 3928 ESI6180U DOOR PANEL ASSEMBLY ...
Страница 12: ...Page 12 DW 107 MODELS ESI6180X EX VIEW DRAWING 3925 ESI6180U BASKET ASSEMBLY ...