background image

Page 

21  DW 107

 

 

OPTIONS FOR IMPROVING WASHING PERFORMANCE 

 
In cases in which the user is dissatisfied with the wash performance, a procedure has been developed 
(exclusively for Service Engineers) that makes it possible to utilise a series of supplementary options 
which improve the wash performance. 
These options are memorised in the electronic control system and consist of three functions, each 
identified by a specific code which allows them to be used when necessary. 
 

 DISPLAY 
SUPPLEMENTARY OPTIONS

 

[- - 0] 

[- - 1] 

[- - 2] 

[- - 3] 

Supplementary water fill (+ 24%) in all fill phases. Impulse 

(

puls

) wash replaced by 

ctrl

 wash  

(

Constant motor speed 2800rpm)

 

-- 

YES 

-- 

YES 

Supplementary cold rinse (

+ 1

)  

 

YES YES 

SETTING THE WASHING PARAMETERS.

With the door Closed and the Dishwasher switched Off (Programme Selection mode) 

1. 

Press and hold down. 

Sw3

 & 

Sw4

 simultaneously  

2

. Press 

Sw0 

to switch the dishwasher on. 

3

. Hold down 

Sw3

 & 

Sw4

 for about 

5sec

 after which the Buzzer will sound 

The 3 digits on the display will show: 

 

Dgt_1 & Dgt_2 [

- -

] two segments lit. 

 

Dgt_3 = [ 

] one number [ 0, 1, 2, 3 ] identifying the supplementary options. 

Example [

- - 0

] - no options (standard setting). 

 

To switch from one option to the next Press 

Sw1

 repeatedly [ 0, 1, 2, 3 …0..]. 

 

To confirm selection of the options Press 

Sw2

 

Press 

Sw0

 to exit the set-up procedure. 

 

COMPONENT DIAGNOSTICS TEST 

 

The diagnostics procedure is divided into two parts: 

Part 1 

provides the Service Engineer with information regarding the status of the dishwasher. 

Part 2 

makes it possible to check the electrical components for correct operation.

 

SELECTING THE COMPONENT DIAGNOSTICS ROUTINE 

 

With the door OPEN and the dishwasher switched OFF (Programme selection mode): 

1. Press and hold down 

Sw1

 & 

Sw4 

2. Press 

Sw0 

to switch the dishwasher on. 

After about 5 seconds, the 3 Digits and all the LEDs light for 

5 seconds 

and the buzzer sounds 

(sequence_B). 

After 

5 seconds

, the display shows: 

a

) The SOFTWARE VERSION is displayed as follows 

DGT_1   [   ] off 

DGT_2   [ 

] number [ 0 ... 9 ] 

DGT_3   [ 

] letter [ A, b, C, d, ...] 

Example: [. 

3 A

] = Software version of control board. 

*

Press 

Sw1 

repeatedly: the three digits will display the following information: 

Содержание ESI6180U

Страница 1: ...NER ASSEMBLY 2 3 ELECTRICAL ASSEMBLY 4 5 WATER CIRCUIT ASSEMBLY 6 7 WATER SOFTENER ASSEMBLY 8 9 DOOR PANEL ASSEMBLY 10 11 BASKET ASSEMBLY 12 13 PROGRAMME CHART 14 WIRING DIAGRAM 15 CIRCUIT DIAGRAM 16 COMPONENT TESTING SERVICE 17 REGENERATION CYCLE 17 18 SAFETY FEATURES CONTROLS ALARMS 18 20 OPTIONS FOR IMPROVING WASH PERFORMANCE 21 COMPONENT DIAGNOSTICS TEST 21 23 FUNCTION DIAGNOSTICS CYCLE 23 24 ...

Страница 2: ...Page 2 DW 107 MODELS ESI6180X EX VIEW DRAWING 3927 ESI6180U OUTER PANEL LINER ASSEMBLY ...

Страница 3: ...al 1 335 1523261 00 4 Gear Wheel 1 344 1522344 05 8 Latch 1 505 1522337 02 9 Trimming Tub Cabinet 1 514 1522520 03 8 Socket Adjustable 1 521D 1526576 00 2 Cover Latch Hole 1 523 1522029 12 1 Bracket and Roller Assembly Grey 4 523B 1521220 03 6 Bracket Re Enforcement Roller 4 527 1523520 10 2 Ferrule Grey 1 531 1523262 11 9 Screw Adjusting Central Foot 1 538 1522335 01 5 Piece Distance Crosspiece R...

Страница 4: ...Page 4 DW 107 MODELS ESI6180X EX VIEW DRAWING 3926 ESI6180U ELECTRICAL ASSEMBLY ...

Страница 5: ...d Display 1 019 50226589 00 5 Lamp Indicator 1 037 1521594000 Box Junction 1 048 50261253 00 4 Sensor Temperature Element 1 110 0055 250 455 Tube Pressure Switch 1 118 1525531 30 5 Dispenser Detergent Grey 1 119 50267511 00 9 Impellors Assembly Inc Items 130 130A 1 130 1520292002 Gasket Pump Front 50 39 mm Dia 1 130A 1520292101 Gasket Pump Front 63 09 mm Dia 1 137 1520170 03 4 Float 1 251 1522489 ...

Страница 6: ...Page 6 DW 107 MODELS ESI6180X EX VIEW DRAWING 3890 ESI6180U WATER CIRCUIT ASSEMBLY ...

Страница 7: ...or Water Sump to Heater 1 127B 1523118 10 5 Connector Manifold Grey 1 130A 1523119 01 2 Seal Channel Drainage 1 130B 1522414 02 6 Gasket Sump 1 130D 1520772003 Gasket Column 1 130E 1522802 00 6 Sealing Strip 1 130F 1240151009 Gasket Hose 1 132A 1529841 80 9 Column and Gasket Assembly 1 135A 1524902 40 8 Channel Drainage Grey 1 139 1524786 30 6 Arm Bottom Spray Grey 1 139A 1524744 10 7 Arm Upper Sp...

Страница 8: ...Page 8 DW 107 MODELS ESI6180X EX VIEW DRAWING 3924 ESI6180U WATER SOFTENER ASSEMBLY ...

Страница 9: ...10A 110E 130C 514 1 127A 1522340 03 1 Connector Outlet Valve 1 130 1525274 00 5 Seal Decalcifier 1 130A 1522338 00 1 Gasket Regen Tank 1 130C 50659231 00 0 Seal Round 1 137 1522447 00 0 Float 1 138 1522418 03 5 Membrane Outlet Valve 1 514 2239010050 Bushing 1 521 1520251 60 2 Bung Decalcifier Grey 1 523 1522346 02 0 Support Float 1 527 1520250 10 9 Ferrule Decalcifier Grey 1 527A 1524050 40 6 Ferr...

Страница 10: ...Page 10 DW 107 MODELS ESI6180X EX VIEW DRAWING 3928 ESI6180U DOOR PANEL ASSEMBLY ...

Страница 11: ...lack 1 1 344 50272150 00 9 Latch Kit Bridging Plug Inc Items 007 518 1 1 509A 1520419 14 2 Tie Hinge 1 1 510 1524908 02 5 Panel Control Black 1 1 514 1525612 00 6 Bush Push Button 5 5 518 1526414 00 6 Plug Bridging 1 1 523A 1523620 06 8 Bracket Blind Panel Bottom 1 1 525 1521536 23 3 Button Push Black 1 1 525A 3565025 03 2 Button Push Programmer Black 5 5 530 355405201 3 Handle Door Black 3500 mm ...

Страница 12: ...Page 12 DW 107 MODELS ESI6180X EX VIEW DRAWING 3925 ESI6180U BASKET ASSEMBLY ...

Страница 13: ...3A 523C 581B 1 319A 1525575 41 9 Basket Upper Grey 1 320 1525019 10 3 Grate Cutlery Basket Grey 1 342 1525593 00 8 Basket Assy Cutlery Grey Inc Item 320 1 342B 1524377 10 6 Basket Knife Grey 1 523A 50269757 00 6 Roller Assembly Lower Basket Grey 4 523C 50269765 00 9 Wheel Kit Lower Basket R H Grey 2 50269766 00 7 Wheel Kit Lower Basket L H Grey 2 581B 1523142 10 5 Partition Adjustable Grey 1 ...

Страница 14: ...TANT SAFETY NOTICE This diagram has been prepared for use by electrically qualified service technicians The manufacturer cannot be held responsible for the interpretation of its service publications nor for any injury or damage that may occur in connection with their use ...

Страница 15: ...ANT SAFETY NOTICE This diagram has been prepared for use by electrically qualified service technicians The manufacturer cannot be held responsible for the interpretation of its service publications nor for any injury or damage that may occur in connection with their use ...

Страница 16: ...TANT SAFETY NOTICE This diagram has been prepared for use by electrically qualified service technicians The manufacturer cannot be held responsible for the interpretation of its service publications nor for any injury or damage that may occur in connection with their use ...

Страница 17: ... 8 OK INFINITY With Rinse Aid RINSE AID SENSOR D1 D2 0 Ω Without Rinse Aid INFINITY With Salt SALT SENSOR E4 E5 0 Ω Without Salt 6 030 Ω 8 at 20 ºC TEMPERATURE SENSOR E2 E3 1 010 Ω 8 at 65 ºC 700 Ω 8 if the RESET solenoid is interrupted RESET SOLENOID E1 D3 610 Ω 8 OK DRAIN MOTOR E1 F1 70 Ω 8 OK WASHING MOTOR E1 F3 50 Ω 8 OK REGENERATION SOLENOID E1 F4 5 100 Ω 8 OK FILL SOLENOID ANTI FLOODING devi...

Страница 18: ...To modify the level of regeneration press Sw4 repeatedly within 5sec The Display L indicates the corresponding regeneration level in sequence every time the key is pressed All remaining keys are disabled Five seconds after pressing Sw4 for the last time the selected regeneration level is stored in memory and the dishwasher returns to the previous condition Programme Selection mode SAFETY FEATURES ...

Страница 19: ...OTE Refer to the table of Alarms on Page 27 for possible causes NTC TEMPERATURE SENSOR ALARMS A L 1 A L 2 This alarm is operative after the initial water fill phase of the cycle until the end of the final wash phase The impedance of the NTC sensor is monitored constantly NTC SENSOR SHORT CIRCUITED ALARM A L 1 If the impedance is too low equivalent to a temperature of 90 C or more based on the conv...

Страница 20: ...A L 6 This control procedure is operative in all the drain phases and checks the status of the pressure switch in order to ensure that the cycle is performed correctly In all the final drain phases and before passing to the subsequent fill phase the pressure switch contact must switch to Empty 1 2 If the contact is closed on Full 1 3 the drain phase is repeated At the end of the second drain phase...

Страница 21: ... The 3 digits on the display will show Dgt_1 Dgt_2 two segments lit Dgt_3 0 one number 0 1 2 3 identifying the supplementary options Example 0 no options standard setting To switch from one option to the next Press Sw1 repeatedly 0 1 2 3 0 To confirm selection of the options Press Sw2 Press Sw0 to exit the set up procedure COMPONENT DIAGNOSTICS TEST The diagnostics procedure is divided into two pa...

Страница 22: ... DGT_1 DGT_2 A L alarm DGT_3 number 1 2 3 4 5 6 7 8 alarm code Example A L 4 Anti flooding alarm Press Sw1 again to pass to the Component Diagnostics procedure PART 2 e COMPONENT DIAGNOSTICS The display shows DGT_1 DGT_2 C d two letters DGT_3 number 0 1 2 3 4 5 6 Reference number Press Sw1 repeatedly It is now possible to check the operation of each electrical component in sequence The relative co...

Страница 23: ...sion a To repeat the test Press Sw1 again it restarts from section b Page 22 and so on Press Sw0 to exit the test routine FUNCTION DIAGNOSTICS CYCLE The purpose of the Function Diagnostics cycle is to provide the Service Engineer with a rapid test for the washing programme sub phases by passing through each phase of the cycle sequentially In this way it is possible to check the functions which are...

Страница 24: ... about 5 seconds after which the buzzer will sound The 3 digits on the display will alternately indicate the last programme performed and two letters abbreviation for Function Diagnostics e g P 3 F d 4 Press Sw1 to select the desired cycle 5 Press Sw5 to start the cycle The 3 digits on the display will indicate F d 1 in which 1 indicates the number of the current sub phase as each cycle begins wit...

Страница 25: ...tions which comprise a traditional cycle This test is designed to action all the actuators fill solenoid valve regeneration solenoid valve reset solenoid valve washing and drain motor heating element and detergent dispenser in a cycle in which the operating times for each are shortened Drain Reset Fill Dispen 10 Wash Drain Reset Fill Disp 10 Regen 2 Fill Drain Drain Reset Fill Wash Drain Reset Fil...

Страница 26: ...s switched off by pressing Sw0 or in case of a power failure the diagnostics routine is interrupted but not cancelled when the dishwasher is switched on again the cycle resumes normally from the point at which it was interrupted To cancel the diagnostics cycle currently being performed press Sw5 and hold down for 5 seconds At the end of the cycle the display shows three central segments to indicat...

Страница 27: ...ssure switch does not switch to FULL 1 3 within 4 minutes after the solenoid is energised PRESSURE SWITCH ON EMPTY 1 2 After correct level is reached the pressure switch returns to EMPTY 1 2 and does not return to FULL 1 3 within 90 seconds a Tap closed b Fill hose kinked intervention of Aqua stop device c Water mains pressure 30 kPa 4 PSI d Intervention of ANTI OVERFLOW device e Fill solenoid con...

Страница 28: ...l system controls the operation of the motor at different speeds controlled or variable The signal transmitted by the tachimetric sensor allows the electronic control system microprocessor to detect the speed of the motor after performing a series of calculations the control system switches on the Triac in order to generate the correct motor speed The following motor speeds are used during the was...