Remote Blower Motor System Kit

PN # EI16DDPRKS

Remote Blower Motor System Kit Specifications

 1600 CFM Remote Blower Motor System Kit is designed for use with 

Downdraft Vent models (36") EI36DD10KS and (30") EI30DD10KS. For 

complete 36" or 30" Downdraft Vent / Cooktop Countertop Preparation 

planning information and Downdraft Vent cutout dimensions, refer to 

model-specific Downdraft Vent product page. For complete installation 

details, refer to model-specific Product Installation Guide on web.

 Remote Blower Motor installation requires use of transition duct,  

pre-attached to Downdraft chassis housing. For complete blower motor 

installation details, refer to Product Installation Guide on web. 

 Voltage Rating – 120V / 60 Hz / 15 Amps

 Connected Load (kW Rating) = 0.47 kW (For use on adequately wired 

120V, dedicated circuit having 2-wire service with a separate ground 

wire. Appliance must be grounded for safe operation.)

 Amps @ 120 Volts – 3.0 Amps

 Do not use same circuit as cooktop.

 Always consult local and national electric codes. Check local building 

codes for installation requirements, as they may vary per locale.

 Choose installation location where Remote Blower Motor is conveniently 

accessible – and electrical power can be provided to connect main 

blower housing with Downdraft Vent control box.

 Possible Remote Blower installation locations are: on floor joists, ceiling 

joists, wall studs or exterior wall.

 Installation on exterior roof or exterior wall requires use of Outdoor 

Weather Kit (PN # WK-SP360) to cover and protect Remote Blower 

Motor housing from weather.

 Main blower housing designed for mounting to joists or studs on 16" 

centers. Four lag bolts provided for attaching housing to joists, studs  

or other structural members; housing can NOT be directly attached  

to wallboard, ceiling panels or other non-structural materials.

 When mounting main blower housing between floor joists or wall studs, 

minimum 2x4 wood spacer required to space blower housing off floor or 

wall. Spacers should be properly secured to joists or studs and NOT to 

sub-floor or wall materials.

 Vent exhaust air outside only.

 Exhaust Duct Required – Galvanized or aluminum duct in 8" or 10" round; 

or 3-1/4" x 14", 4" x 14" or 4-3/4" x 14" rectangular; or combination of 

both. PVC should be used if installing under concrete slab.

 Three blower discharge direction options available. Transition duct ships 

with discharge pre-positioned down; left or right discharge requires 

90-degree duct rotation.

 Consider ductwork location before cutting hole in cabinet. 

 For maximum efficiency, use shortest and straightest duct run possible. 

System operates most efficiently with up to 60 equivalent feet of duct; 

Downdraft Vent operates properly with ductwork up to 100 equivalent 

feet. 

(Refer to Calculating Duct Length Table in Product Installation Guide.)

 Do not use flexible duct. Round duct instead of rectangular duct 

recommended, especially when elbows are required.

 Thermal breaks such as short section of nonmetallic duct, should be used 

in areas of extreme cold. Cold weather installations should have additional 

backdraft damper installed.

 High level of airflow may affect gas flame on some gas cooktop models.

Optional Accessories

 Outdoor Weather Kit – (PN # WK-SP360).

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at electroluxappliances.com for detailed instructions.

Downdraft Vent - Blower Motor Kit (Remote)

EI16DDPRKS

Содержание EI16DDPRKS

Страница 1: ...ng Connected Load kW Rating 120 Volts Amps 120 Volts Sones Rating Shipping Weight WITH INTEGRATED BLOWER MOTOR KIT Features Air Discharge Air Delivery CFM Blower Type Sound Level dBA Exhaust Duct Duct Required Specifications Product Dimensions Height Including 10 Rise Width Depth Voltage Rating Connected Load kW Rating 120 Volts Amps 120 Volts Sones Rating Shipping Weight For use on adequately wir...

Страница 2: ...ackdraft damper installed High level of airflow may affect gas flame on some gas cooktop models Blower Motor System Options 1600 CFM Remote Blower Motor System Kit PN EI16DDPRKS 600 CFM Integrated Blower Motor System Kit PN EI06DDPIKS Note For planning purposes only Refer to Product Installation Guide on the web at electroluxappliances com for detailed instructions Maximum 41 2 gap allowed between...

Страница 3: ...re on floor joists ceiling joists wall studs or exterior wall Installation on exterior roof or exterior wall requires use of Outdoor Weather Kit PN WK SP360 to cover and protect Remote Blower Motor housing from weather Main blower housing designed for mounting to joists or studs on16 centers Four lag bolts provided for attaching housing to joists studs or other structural members housing can NOT b...

Страница 4: ...ways consult local and national electric codes Check local building codes for installation requirements as they may vary per locale Locate grounded electrical outlet for 28 long power cord within reach able distance When installing 36 vent in 36 wide cabinet or 30 in 30 wide cabinet outlet cannot be located on back wall of cabinet but can be wall mounted with access hole in cabinet Vent exhaust ai...

Отзывы: