Downdraft Vent

EI30DD10K S

Downdraft Vent Specifications

 Downdraft Vent requires installation with Blower Motor System Kit –  

1600 CFM Remote option or 600 CFM Integrated option (kit ordered 

separately). Vent ships with transition duct pre-attached to chassis housing 

for Remote Blower Motor installation and is removable for Integrated Blower 

Motor installation. For Blower Motor System planning information, refer 

to specific kit’s specifications page; for complete installation details and 

specifications, refer to specific Product Installation Guides on web. 

 Voltage Rating – 120V / 60 Hz / 15 Amps

 Connected Load (kW Rating) and Amps @ 120 Volts – Refer to specific 

Blower Motor System Kit specification page.

 Do not use same circuit as cooktop.

 Always consult local and national electric codes. Check local building 

codes for installation requirements, as they may vary per locale.

 Locate grounded electrical outlet for 28"- long power cord within reachable 

distance. When installing vent in 30"- wide cabinet, outlet cannot be 

located on back wall of cabinet, but can be wall-mounted with access 

hole in cabinet.

 Downdraft Vent designed for installation with cooktop in island, peninsula 

or conventional installation. 

(Cutout template provided, packed with vent.)

 To ensure proper installation with cooktop, refer to model-specific 

cooktop installation guide on web for dimensions, countertop cutout 

dimensions and cabinet requirements; oversized cabinets recommended 

for ease of installation. Due to varying cooktop depths, tight fit is possible 

between cooktop and vent, depending on overall depth of countertop.

 Pre-formed countertops with raised lip and /or backsplash may not 

allow enough flat area for proper installation. Minimum 2-5/16" of flat 

countertop required behind cooktop and 2-1/16" necessary between 

back edge of cooktop and inside of cabinet back. 

 To ensure adequate clearance for air vent when raised /lowered, 1/8" gap 

needed between back edge of cooktop and front of downdraft top trim.

 Vent exhaust air outside only.

 Exhaust Duct Required – Refer to specific Blower Motor System Kit 

specifications page.

 Three blower discharge direction options available. Pre-positioned with 

discharge facing down; left or right discharge requires 90-degree transition 

duct rotation. Transition duct can also be mounted to back of chassis 

housing with minimum 3-3/4" clearance to back of cabinet wall.

 Consider ductwork location before cutting hole in cabinet. 

 For maximum efficiency, use shortest and straightest duct run possible. 

System operates most efficiently with up to 60 equivalent feet of duct; 

Downdraft Vent operates properly with ductwork up to 100 equivalent 

feet. 

(Refer to Calculating Duct Length Table in Product Installation Guide.)

 Do not use flexible duct. Round duct instead of rectangular duct 

recommended, especially when elbows are required.

 Thermal breaks such as short section of nonmetallic duct, should be used 

in areas of extreme cold. Cold weather installations should have additional 

backdraft damper installed.

 High level of airflow may affect gas flame on some gas cooktop models.

Blower Motor System Options

•  

1600 CFM Remote Blower Motor System Kit – (PN # EI16DDPRKS).

• 

600 CFM Integrated Blower Motor System Kit – (PN # EI06DDPIKS).

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at electroluxappliances.com for detailed instructions.

Maximum 4

1

/

2

"gap allowed between inside cabinet

back and chassis BEFORE downdraft stabilizing brackets

will require wood support installation for mounting

* For minimum clearance,

refer to specific Blower

Motor Kit specifications.

  1

/

4

"min.

2

5

/

16

"

Front to back

inside cabinet depth

1

/

8

"

(A)Countertop

     raised lip

(B)

Countertop

backsplash

Downdraft

top trim

Cooktop

Clearance

required

behind

downdraft

top trim

Transition duct

(or Integrated Blower Motor)

Min. clearance*

Downdraft

chassis

housing

2

1

/

16

"

Downdraft Vent

EI30DD10KS

Blower Motor System Kit Options: 

Downdraft Vent requires installation with

Blower Motor System Kit – 1600 CFM Remote option or 600 CFM Integrated option

(kit ordered separately). Vent ships with transition duct pre-attached to chassis

housing for Remote Blower Motor installation and is removable for Integrated

Blower Motor installation. For Blower Motor System planning information, refer to

specific kit’s specifications page; for complete installation details and specifications,

refer to specific Product Installation Guides on web.

 Typical 30" Downdraft Vent /Cooktop Installation

Designed for use with cooktop in conventional, island or peninsula installation.

Downdraft Vent requires installation with Blower Motor System Kit.

30" Downdraft Vent Dimensions

with Transition Duct

 

(for Remote Blower

Motor installation option)

**Only used for vent installation

with remote blower option.

Discharge pre-positioned down;

left or right discharge requires

90-degree duct rotation.

30" Downdraft Vent/

Cooktop Countertop

Preparation

Cooktop edges

26

15

/

16

"

2

1

/

16

"

30" Downdraft Vent cutout

Countertop Cutout Dimensions

(Cutout template provided, packed with vent.)

Top

View

Cooktop Installation Notes:

 To ensure

proper installation, refer to model-

specific cooktop installation guide on

web for dimensions, countertop cutout

dimensions and cabinet requirements;

oversized cabinets recommended

for ease of installation. Due to varying

cooktop depths, tight fit is possible

between cooktop and vent, depending

on overall depth of countertop.

Countertop Preparation Notes:

 Pre-formed

countertops with (A) raised lip and/or

(B) backsplash may not allow enough flat

area for proper installation. Minimum

2-5/16"of flat countertop required behind

cooktop and 2-1/16"necessary between

back edge of cooktop and inside of cabinet

back. To ensure adequate clearance for

air vent when raised/lowered,1/8"gap

needed between back edge of cooktop

and front of downdraft top trim.

30"

 17

13

/

16

"

 10"

Rise

26

7

/

8

"

 Transition

    duct**

(with 3-way

 ducting)

Top trim

Chassis

housing

2

3

/

16

"

 35

13

/

16

"

5

9

/

16

"

2

1

/

4

"

1

7

/

16

"

Control

box

Power

cord

2

1

/

2

"

Electrical Supply Outlet Installation

for 30" Downdraft Vent

Electrical Installation Notes:

 All vertical dimensions relative to top

surface of countertop; all horizontal dimensions relative to cutout in

countertop. Locate grounded electrical outlet for 28"-long power cord

within reachable distance. When installing vent in 30"-wide cabinet,

outlet cannot be located on back wall of cabinet, but can be wall-mounted

with access hole in cabinet. Ensure that access to outlet will NOT be

obstructed by ducting after installation.

 19

1

/

16

"

CL

Mount 120 VAC grounded

outlet inside cabinet, confined

to shaded area.

 7

7

/

8

" 8

3

/

4

"

 14

3

/

4

"

Cabinet

side wall

 Cabinet

side wall

6

1

/

2

"

 22

1

/

8

"

 23

3

/

4

"

4

5

/

8

"

9

1

/

2

"

13

1

/

2

"

Countertop surface

13

1

/

2

"

Содержание EI16DDPRKS

Страница 1: ...ng Connected Load kW Rating 120 Volts Amps 120 Volts Sones Rating Shipping Weight WITH INTEGRATED BLOWER MOTOR KIT Features Air Discharge Air Delivery CFM Blower Type Sound Level dBA Exhaust Duct Duct Required Specifications Product Dimensions Height Including 10 Rise Width Depth Voltage Rating Connected Load kW Rating 120 Volts Amps 120 Volts Sones Rating Shipping Weight For use on adequately wir...

Страница 2: ...ackdraft damper installed High level of airflow may affect gas flame on some gas cooktop models Blower Motor System Options 1600 CFM Remote Blower Motor System Kit PN EI16DDPRKS 600 CFM Integrated Blower Motor System Kit PN EI06DDPIKS Note For planning purposes only Refer to Product Installation Guide on the web at electroluxappliances com for detailed instructions Maximum 41 2 gap allowed between...

Страница 3: ...re on floor joists ceiling joists wall studs or exterior wall Installation on exterior roof or exterior wall requires use of Outdoor Weather Kit PN WK SP360 to cover and protect Remote Blower Motor housing from weather Main blower housing designed for mounting to joists or studs on16 centers Four lag bolts provided for attaching housing to joists studs or other structural members housing can NOT b...

Страница 4: ...ways consult local and national electric codes Check local building codes for installation requirements as they may vary per locale Locate grounded electrical outlet for 28 long power cord within reach able distance When installing 36 vent in 36 wide cabinet or 30 in 30 wide cabinet outlet cannot be located on back wall of cabinet but can be wall mounted with access hole in cabinet Vent exhaust ai...

Отзывы: