background image

42

S

Innehållsförteckning ............................................................. 2

N

Innholdsfortegnelse ............................................................ 12

DK

Indholdsfortegnelse ............................................................ 22

FIN

Sisällysluettelo .................................................................. 32

UK

Contents ............................................................................ 42

D

Inhalt.................................................................................. 52

Contents

Information about safety ........................................................................................ 42

Description of the hood .......................................................................................... 44

How to use the hood .............................................................................................. 45

Maintenance and cleaning. .................................................................................... 46

When the hood does not work. .............................................................................. 47

Accessories: ........................................................................................................... 47

Technical data ........................................................................................................ 48

Installation .............................................................................................................. 48

     Information about safety

The hood is destined uniquely for non-professional use in a domestic setting. It complies with international

safety quality regulations and requisites. The safety measures cannot, however, eliminate all risks of accidents.

Read the instructions, suggestions, and warnings carefully before installing and starting to use the hood.

Pay particular attention to the paragraphs with a triangular warning symbol to avoid damage to people or

objects. We recommend conserving the instructions booklet that must be supplied in case of sale or cession of

the hood to third parties.

For the installer

• When used as an extractor unit, the hood must be

fitted with a  150mm diameter hose.

Attention:  The  hose  is  not  supplied  and  must

be  purchased  separately.

• The hood must be installed at a distance of least

50 cm above the cooking top or electric plates,

or at least 65 cm above gas rings or gas tubes.

• The hood is considered disconnected only when

the plug is disconnected or the fuse removed.

• Observe the rules and regulations concerning

the elimination of fumes. The waste disposal

tube of the hood cannot therefore be connected

to a conduit that is used for removing fumes

from equipment supplied by power different to

electricity, e.g. a boiler or a fireplace.

•

If  the  instructions  for  installation  for  the  gas

hob  specify  a  greater  distance,  this  must  be

adhered  to.

• The  national  Standard  on  fuel-burning  systems

specifies  a  maximum  depression  of  0.04  mbar  in

such  rooms.

• The  air  outlet  must  not  be  connected  to  chimney

flues or combustion gas ducts. The air outlet must

under no circumstances be connected to ventilation

ducts for rooms in which fuel-burning appliances

are  installed.

• The  air  outlet  installation  must  comply  with  the

regulations  laid  down  by  the  relevant  local

authorities.

• When  the  unit  is  used  in  extraction  mode,  a

sufficiently large ventilation hole must be provided,

with  dimensions  that  are  approximately  the  same

as the outlet hole.

• National and regional building regulations impose

a number of restrictions on using hoods and fuel-

burning  appliances  connected  to  a chimney, such

as  coal  or  oil  room-heaters  and  gas  fires,  in  the

same  room.

• Hoods  can  only  be  used  safely  with  appliances

connected  to  a  chimney  if  the  room  and/or  flat

(air/environment  combination)  is  ventilated  from

outside  using  a  suitable  ventilation  hole  approxi-

mately 500-600 cm

 large to avoid the possibility

of a depression being created during operation of

the  hood.

• If  you  have  any  doubts,  contact  the  relevant

controlling authority or building inspector’s office.

• Since  the  rule  for  rooms  with  fuel  burning

appliances is “outlet hole of the same size as the

ventilation hole”, a hole of 500-600 cm

2

, which is

to say a larger hole, could reduce the performan-

ce  of  the  extractor  hood.

• If the hood is used in its recirculation mode, it will

operate simply and safely in the above conditions

Содержание EFCR 942

Страница 1: ...Instruktionsbok Bruksanvisning Brugsvejledning EFCR 942 EFC 9426 6426 Käyttöohje User Manual Gebrauchsanweisung N DK S FIN UK D ...

Страница 2: ...es from equipment supplied by power different to electricity e g a boiler or a fireplace If the instructions for installation for the gas hob specify a greater distance this must be adhered to The national Standard on fuel burning systems specifies a maximum depression of 0 04 mbar in such rooms The air outlet must not be connected to chimney flues or combustion gas ducts The air outlet must under...

Страница 3: ... out any work on the hood including replacing the light bulb take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker It is very important to clean the hood and replace the filter at the recommended intervals Failure to do so could cause grease deposits to build up resulting in a fire hazard The appliance is not intended for use by young children or infirm persons...

Страница 4: ... an external system of aspiration A telescopic flue that includes an upper and a lower U section 1 montage template 1 support for the flue complete with ventilation system 1 deflector concerns only the EFC 9426 6426 model 1 plastic envelope containing the montage and documentationmaterial The following accessories can be obtained from yourretailer Active carbon filter Type 160 When the hood is con...

Страница 5: ...re the LED that signals filtersaturationisinactive Activate the LED as indicated below if the hood has to be used with the carbon filter Press keys B and G simultaneously for three seconds The D anti fat filter LED lights up and then the E carbon filter LED as well The LED that signals the saturation of the active carbon filter has been activated Deactivation Press keys B and G simultaneously for ...

Страница 6: ...consists of aluminium reticules upon which the fat is collected Clean the filter by immersing it in hot water or putting it into the dishwasher Wait until the filter is dry before remounting it Warning Putting the filter into the dishwasher may fade the filter Active carbon filter An active carbon filter must be used only if the hood is used in the recirculating version filtering An original ELECT...

Страница 7: ...et If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood If after all these checks the problem persists contact your local Service Force Centre quoting the model and serial number Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee custom...

Страница 8: ...ipe of the hood cannot be connected to a conduit that is used for evacuating fumes of apparatuses supplied with a different energy to electricity e g a boiler or a fireplace Electrical connection The electricity socket must be positioned inside the flue The hood has a supply cable and a plug provided with grounding and a voltage of 220 240V Technical data EFCR 942 EFC 9426 EFC 6426 Overall dimensi...

Страница 9: ...tate the installation of the hood fig 7 Make a hole as indicated in the diagram and insert two wall dowels two hooks and two screws fig 7 Hang up the hood Adjust the position with the screws on the hooks of the hood Fig 8 Mark the points on the wall from inside the hood corresponding to the holes to use for the definitive fixing of the hood Fig 9 Remove the hood Make two holes Ø 8mm and insert two...

Страница 10: ...nnection ring of ventilator screen F recirculation version Attention Concerns only the EFCR 942 model Connect the waste disposal tube to one external aspiration unit see following paragraph Connection to an external motor Connect the electricity Attention Only for the EFCR 942 model It is also necessary to carry out the electrical connection to an external aspiration unit see following paragraph C...

Страница 11: ...ger the waste disposal tube is the worse will be it aspiration capacity The length of the waste disposal tube must never in any case be longer than 7 metres All the material necessary for connecting the hood to the external motor tubes electricity cables etc is not supplied and must be purchased separately Electrical connection of the external motor Check the position of the derivation box B above...

Страница 12: ...s chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world Electrolux 2003 Electrolux HemProdukter AB S 105 45 Stockholm www electrolux se Electrolux Home Products Risløkkveien 2 0508 Oslo Tlf 81 53 02 22 E mail eha electrolux no Internett www electrolux no Electrolux Husholdningsapparater A S Lundtoftevej 160 2800 Lyngby Tlf 45 ...