background image

51

N

B

S

L

H05 VVF (3 x 0.75)

cable.

Connection  to  external  motor

Concerns only the EFCR 942 model.

The hood is not equipped with an internal motor

and must be connected to an external motor (to

purchase separately).

The electrical connection must be carried out with

the help of suitable connections.

Attention! Use only the external motor

supplied by the constructor.

Connecting the waste disposal tube to the

external motor.

The external motor must be installed at a point

sufficiently spacious with respect to the regulations

in force.

The external motor must be connected to the

hood with a waste disposal tube with an adequate

diameter (min. 150 mm).

Note that the longer the waste disposal tube is,

the worse will be it aspiration capacity. The length

of the waste disposal tube must never, in any case,

be longer than 7 metres.

All the material necessary for connecting the hood

to the external motor (tubes, electricity cables,

etc.) is not supplied and must be purchased

separately.

Electrical connection of the external motor

·

Check the position of the derivation box 

B

above the hood.

·

Remove screws 

and open the cover of box

B.

·

Open the cable cover removing screws 

L

.

·

Use an H05 VVF (3 x 0.75) type cable for

connecting the hood.

·

Connect the motor cable clamps to the

terminal board in derivation box 

B

 on the

hood.

·

Close the cable cover with screws 

L

.

·

Close the 

B

 cover and fix the 

screws.

·

Connect the hood to the power supply.

Fig. 11

External motor (for external installation)

942 121 135

External motor (for external installation)

942 121 182

Содержание EFCR 942

Страница 1: ...Instruktionsbok Bruksanvisning Brugsvejledning EFCR 942 EFC 9426 6426 Käyttöohje User Manual Gebrauchsanweisung N DK S FIN UK D ...

Страница 2: ...es from equipment supplied by power different to electricity e g a boiler or a fireplace If the instructions for installation for the gas hob specify a greater distance this must be adhered to The national Standard on fuel burning systems specifies a maximum depression of 0 04 mbar in such rooms The air outlet must not be connected to chimney flues or combustion gas ducts The air outlet must under...

Страница 3: ... out any work on the hood including replacing the light bulb take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker It is very important to clean the hood and replace the filter at the recommended intervals Failure to do so could cause grease deposits to build up resulting in a fire hazard The appliance is not intended for use by young children or infirm persons...

Страница 4: ... an external system of aspiration A telescopic flue that includes an upper and a lower U section 1 montage template 1 support for the flue complete with ventilation system 1 deflector concerns only the EFC 9426 6426 model 1 plastic envelope containing the montage and documentationmaterial The following accessories can be obtained from yourretailer Active carbon filter Type 160 When the hood is con...

Страница 5: ...re the LED that signals filtersaturationisinactive Activate the LED as indicated below if the hood has to be used with the carbon filter Press keys B and G simultaneously for three seconds The D anti fat filter LED lights up and then the E carbon filter LED as well The LED that signals the saturation of the active carbon filter has been activated Deactivation Press keys B and G simultaneously for ...

Страница 6: ...consists of aluminium reticules upon which the fat is collected Clean the filter by immersing it in hot water or putting it into the dishwasher Wait until the filter is dry before remounting it Warning Putting the filter into the dishwasher may fade the filter Active carbon filter An active carbon filter must be used only if the hood is used in the recirculating version filtering An original ELECT...

Страница 7: ...et If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood If after all these checks the problem persists contact your local Service Force Centre quoting the model and serial number Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee custom...

Страница 8: ...ipe of the hood cannot be connected to a conduit that is used for evacuating fumes of apparatuses supplied with a different energy to electricity e g a boiler or a fireplace Electrical connection The electricity socket must be positioned inside the flue The hood has a supply cable and a plug provided with grounding and a voltage of 220 240V Technical data EFCR 942 EFC 9426 EFC 6426 Overall dimensi...

Страница 9: ...tate the installation of the hood fig 7 Make a hole as indicated in the diagram and insert two wall dowels two hooks and two screws fig 7 Hang up the hood Adjust the position with the screws on the hooks of the hood Fig 8 Mark the points on the wall from inside the hood corresponding to the holes to use for the definitive fixing of the hood Fig 9 Remove the hood Make two holes Ø 8mm and insert two...

Страница 10: ...nnection ring of ventilator screen F recirculation version Attention Concerns only the EFCR 942 model Connect the waste disposal tube to one external aspiration unit see following paragraph Connection to an external motor Connect the electricity Attention Only for the EFCR 942 model It is also necessary to carry out the electrical connection to an external aspiration unit see following paragraph C...

Страница 11: ...ger the waste disposal tube is the worse will be it aspiration capacity The length of the waste disposal tube must never in any case be longer than 7 metres All the material necessary for connecting the hood to the external motor tubes electricity cables etc is not supplied and must be purchased separately Electrical connection of the external motor Check the position of the derivation box B above...

Страница 12: ...s chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world Electrolux 2003 Electrolux HemProdukter AB S 105 45 Stockholm www electrolux se Electrolux Home Products Risløkkveien 2 0508 Oslo Tlf 81 53 02 22 E mail eha electrolux no Internett www electrolux no Electrolux Husholdningsapparater A S Lundtoftevej 160 2800 Lyngby Tlf 45 ...

Отзывы: