31
9.2.1 Table of alarm codes
When an abnormal situation occurs that may interfere with machine functioning, the main board activates a safety system which in most cases interrupts the
washing cycle. The last three alarm situations are stored in memory. Using a special procedure, service personnel can display all the alarms stored in memory. The
user is only shown four of the alarms.
The alarms are shown on the display and signalled with “beeps” from the buzzer (if machine is so equipped) or with vocal messages.
Type of
alarm
Shown to user
Description of ALARM
Status of machine
Possible causes
Yes
i10
OPEN THE
TAB
Water fill time-out
(the pressure switch has not
switched to FULL within 90 sec.
during static filling, or fails to switch
to FULL during the first 60 sec. of
dynamic filling at 2800 RPM)
The drain pump starts and then
the cycle stops
Tap closed; Water mains pressure too low; Drain
solenoid / wiring faulty; Pressure switch on water
circuit plugged; Level pressure switch / wiring
faulty; Faulty main board (short circuit on solenoid
triac)
Yes
i20
PUMP
BLOCKED
Water drain time-out
(the pressure switch has not
returned to EMPTY after two drain
phases lasting 120 sec.)
The drain pump starts and then
the cycle stops
Drain circuit plugged / clogged; Drain pump faulty /
obstructed (foreign bodies); Level pressure switch
stuck on FULL (1-3); Pressure switch on water
circuit plugged; Faulty wiring;
Faulty main board.
i30
Yes
Intervention of anti-flooding
device
(drain pump operates)
The cycle stops and the drain
pump starts.
Water leakage from tub – sump and various
couplings (pumps, line to upper spray arm, etc.);
Floating sensor jammed; Faulty microswitch; Fill
solenoid jammed; Faulty main board (short circuit
on solenoid triac); Faulty wiring
i50
Yes
Short circuit on motor triac
(wash pump operates continuously
at maximum speed)
Water fills to operating level (if
necessary), other mechanical
systems fail to operate and cycle
stops. The washing motor
operates at max. speed and alarm
is displayed.
Faulty main board
i60
Si
Overheating
Temperature higher than 78°C
The cycle stops and the drain
pump starts.
Faulty heating element; Safety thermostats (open);
Wiring faulty; NTC-sensor (thermal contact faulty);
Scarce circulation of water in the tub; Wash pump
faulty (damaged impeller) Faulty main PCB
Type of
alarm
Shown to user
Description of ALARM
Status of machine
Possible causes
Содержание DIVA
Страница 35: ...35 10 CIRCUIT DIAGRAMS 10 1 Free standing model ...
Страница 36: ...36 10 2 Talkie Free standing model ...
Страница 37: ...37 10 3 Built in model ...
Страница 38: ...38 10 4 Talkie Built in model ...
Страница 40: ...40 11 2 Talkie Free standing model ...
Страница 41: ...41 11 3 Built in model ...
Страница 42: ...42 11 4 Talkie Built in model ...