Cleaning and hygiene
• Clean the planetary gear housing, the tool holder spindle and the
safety guard with a damp sponge and a detergent - disinfectant
product, then rinse in clean water.
Note: Use cleaning products that are compatible with
the aluminium parts.
4.
1
BETWEEN TWO SESSIONS
• Remove the bowl and tool.
• Using hot water and detergent/disinfectant or degreaser (if working
with greasy products), immerse and wash the inside of the bowl
and the tool in the sink, then rinse in clean water and dry.
ATTENTION!!
Before dismantling any part, disconnect the appliance from the power supply.
Before using any cleaning product, be sure to read the instruction and safety instructions accompanying the product and use
appropriate protective equipment.
Do not clean the machine with a pressure cleaner
4.
2
AFTER USE
• Disconnect the machine.
• Remove the bowl, tool and safety guard.
• Clean the bowl and tools with detergent/disinfectant or de-
greaser in a sink, then rinse in clean water and dry. Only the
bowl may be cleaned in a dishwasher.
• Clean the planetary gear housing, the tool holder shaft, the
safety guard and the cradle, paying particular attention to the
bowl handles and where necessary the outside of the beater
using a damp sponge and a disinfectant/detergent product,
then rinse.
• Check that the different parts have been cleaned correctly.
Note:
- Check that the products used for cleaning are compatible
with the machine part materials.
- Do not use abrasive detergents as these could scratch the
surfaces.
- To clean the accessory appliances, check with the instruction
sheet for each accessory
• On a regular basis: (at least once a month)
- Remove dust from the ventilation slots at the back of the
machine (cause of overheating).
- Wipe and lightly lubricate the raising and lowering pins with Vase-
line.
- Oil the tool-holder shaft (food quality oil or grease).
Do not clean the machine with a pressure cleaner.
4.
3
STRAY FLOUR PARTICLES:
In order to reduce the emission of stray fl our particles while
loading the bowl, it is recommended as follows:
- Empty the fl our bag or the container containing the fl our without
shaking it.
- Pour in the water before putting the fl our in if that is possible
- Always start at slow speed during the water/fl our mixing
- Do not shake an empty fl our bag. Roll it with care.
Keeping to these simple rules will contribute to reducing the
emission of fl our dust and consequently reducing the risks of
allergy linked to that dust.
Fault fi nding
5.
1
THE BEATER WILL NOT START
• Check that:
- The machine is plugged in.
- The electrical power supply to the socket is correct.
- The bowl is in the working position and the safety guard
closed.
• If the beater will still not start:
- Remove the rear plate to check that there is no operating fault
on the variator.
- If « » or « » is not displayed, call for a specialist to
intervene.
• If the beater stops during operation:
- The variator heat sensor has been triggered. Wait for a few
minutes before starting again.
- Reduce the speed or the load (see § 3.3 and 3.4).
Comply with the safety instructions, dangerous voltage (See
§5.2).
5