43
INSTALLING THE HEATER WIRE - STEP 3
1. Remove wires (with terminals) from compressor
starter/overload. On some models you will need to
depress locking tabs located in relay housing
(See Drawing below.)
3. Cut off braid at start of heater. Strip insulation back
about 5/16 inch. Be careful not to damage heater
resistance wire. Splice heater wire ends to loose
leads of adapter harness with furnished wire
connectors.
4. Dress wires away form Condenser Fan Blade and
any sharp edges.
5. Secure wires with electrical tape as necessary.
6. Reinstall Back Panel for proper air flow over
condenser and compressor.
Vacuum
Pump
Connect to Condenser
Outlet
Adapter and
plastic sleeve
INSTALLING THE HEATER WIRE - STEP 2
1. Attach Vacuum Pump and Gauge Set to one end
of Perimeter Hot Tube with an Adapter and Plastic
Sleeve. See illustration on next page.
2. Cutoff waxed end of Fiberglass braid that is
extended past end of heater wire and make knot
in end just a little smaller than inside diameter of
hot tube.
3. Insert knot on end of braid into open end of
Perimeter Hot Tube.
4. With braid inserted, start Vacuum Pump and
place your thumb over end of tube. When good
vacuum is obtained, release your thumb and begin
to feed braid into Hot tube. Continue this process
until string reaches Plastic Sleeve.
NOTE:
Take the time to remove all the bends from
the heater (caused from being rolled up) by pulling
the heater and braid through a shop rag with a small
amount of silicone on the rag and laying it in a roll at
the open end of the Hot Tube it will make heater
installation go faster. Using of a good two stage, 5
CFM Vacuum Pump will also make heater installa-
tion go faster.
5. Disconnect Plastic Sleeve.
6. Pull braid out while pushing equal amount of
braided heater into tube at other end until heater
wireinside braid appears.
Wire splice connector to heater
Wire splice connector to heater
Red
Refrigerator
Harness
Red
White
White
2. Install harness adapter into refrigerator circuit as
shown below.
CONDENSER REPLACEMENT
1. Disconnect electrical supply to refrigerator.
2. Remove compressor access panel.
3. Remove rail and condenser fan shroud screws.
4. Remove fan motor harness clamp located below
heat exchanger wiring harness cover.
5. Disconnect condenser fan motor multiconnector.
6. Pull compressor assembly straight out.
7. Recover refrigerant, using an EPA approved
recovery system.
Содержание BEVERAGE CENTER II
Страница 22: ......
Страница 33: ...32 COMPRESSORWIRING Induction Run Compressor with Relay LADDER SCHEMATIC ...
Страница 34: ...33 WIRING DIAGRAM ...
Страница 61: ...60 ...
Страница 62: ...61 ...
Страница 63: ...62 ...
Страница 64: ...63 ...
Страница 65: ...64 ...
Страница 66: ...65 ...
Страница 68: ...67 Step 3 Step 4 Step 5 Step 6 ...
Страница 69: ...68 Step 8 Step 7 Step 9 Step 10 ...
Страница 70: ...69 Ice Maker Exploded View ...
Страница 71: ...70 Ice Maker Wiring Diagrams Enlarged view ...
Страница 77: ......