TSE-P 02.00 EB
39/60
599 35 24-30
6.1.1 Temperature
control
An NTC sensor fitted to the duct is used to control the drying temperature; two safety thermostats (one of
which is a manual-reset type) are fitted to the casing of the heating element.
“Standard” Version
“High performance” Version
1. NTC sensor for control of
drying temperature
2. Automatic-reset
safety
thermostat
3. Manual-reset
safety
thermostat (150ºC)
4. Drying
heater
NTC Sensor : resistance at 25
°
C
5000
Ω
Manual-reset safety thermostat
Normally closed, opens at 150
°
C
Automatic-reset safety
thermostat
Normally closed, opens at 98
°
C
Normally closed, opens at 110
°
C
Drying heater power
700 + 700 W
1000+1000 W
Fan rate
about 55 m
3
– hour
about 80 m
3
– hour
6.1.2
Determining the drying time:
In automatic cycles, the NTC sensor fitted to the drying condenser is used to control the drying time.
1. NTC temperature sensor
2. Tub-condenser pipe
3. Drying condenser